Liebert GXTTM user manual

User manual for the device Liebert GXTTM

Device: Liebert GXTTM
Category: Power Supply
Manufacturer: Liebert
Size: 1.25 MB
Added : 1/10/2014
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Liebert GXTTM. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Liebert GXTTM.

For your convenience

If looking through the Liebert GXTTM user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Liebert GXTTM on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Liebert GXTTM to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Liebert GXTTM User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Liebert GXTTM but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Liebert GXTTM. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



UPStation GXT™

6 & 10 kVA

230V


USER MANUAL
English

Summary of the content on the page No. 2

IMPORTANT SAFETY INSTRUCTIONS 1. SAVE THESE INSTRUCTIONS. THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS. Read all safety and operating instructions before operating the Uninterruptible Power System (UPS). Adhere to all warnings on the unit and in this manual. Follow all operating and user instructions. This equipment can be operated by individuals without previous training. 2. This product is designed for Commercial/Industrial use only. It is not intended for use with life sup

Summary of the content on the page No. 3

10. Storing magnetic media on top of the UPS may result in data loss or corruption. 11. Turn the UPS off and isolate the UPS before cleaning. Use only a soft cloth, never liquid or aerosol cleaners. GLOSSARY OF SYMBOLS Indicates AC Input Indicates AC Output Indicates Caution: Note the accompanying instruction Indicates the position of a fuse Requests the user to consult the manual for additional information Indicates that the unit contains a valve regulated lead aci

Summary of the content on the page No. 4

INTRODUCTION AND SYSTEM DESCRIPTION Congratulations on your choice of the UPStation GXT™ Uninterruptible Power System (UPS). It provides conditioned power to microcomputers and other sensitive electronic equipment. Upon generation, AC power is clean and stable. However, during transmission and distribution it may be subject to voltage sags, spikes, or complete power failure, which may interrupt computer operations, cause data loss, or even damage equipment. The UPStation GXT protec

Summary of the content on the page No. 5

RECTIFIER/POWER FACTOR CORRECTION (PFC) CIRCUIT In normal operation, the rectifier/power factor correction (PFC) circuit converts mains AC power to regulated DC power for use by the inverter, while ensuring that the wave shape of the input current used by the UPS is near ideal. Extracting this sinewave input current achieves two objectives: the mains power is used as efficiently as possible by the UPS, and the amount of distortion reflected on the mains is reduced. This results in clean

Summary of the content on the page No. 6

CONTROLS AND INDICATORS Fault Indicator UPS ON / BYPASS Alarm Silence / Manual Battery Test UPS ON BATTERY Output OFF / Bypass AC INPUT Load / Battery Level Indicators Fault Indicator (Red) The Fault indicator is illuminated if the UPS has detected a problem. Also, one or more of the load/battery level indicators may be illuminated (refer to Troubleshooting Guide). BYPASS Indicator (Amber) The BYPASS indicator is illuminated when the UPS is operating from BYPASS power.

Summary of the content on the page No. 7

The UPStation GXT is equipped with automatic and remote battery test features. The automatic test occurs every 14 days if a manual battery test has not been performed or if mains has not been interrupted (14 day timer resets if unit goes to battery). Should the battery fail this test, the fault indicator along with the A and C diagnostic LEDs will illuminate and an alarm will sound (refer to Troubleshooting Guide). The remote test feature functions with either SiteNet® 2 or SiteNet® SNM

Summary of the content on the page No. 8

TM DB-9 Intellislot GXT 6 & 10 kVA Communications Communications Component Diagram Port Port 230 & 230X Models Shown Output Voltage Selector Switches TM Intellislot DB-9 Communications Communications Port Port Breakers Output Voltage Selector Switches Battery Input Output Breaker Input Output Battery Breaker Breaker Breaker Hardwire Terminal Blocks Hardwire Terminal Blocks Adjustable levels 6

Summary of the content on the page No. 9

OPERATING MODES NORMAL MODE OPERATION- UPS mode During normal operation, mains power provides energy to the UPS. The filters, the power factor correction circuit and the inverter process this power to provide computer grade power to connected loads. The UPS maintains the batteries in a fully charged state. The four green LED’s indicate an approximate level of load in 25% increments. If the UPS becomes loaded beyond full rating, the fifth (amber) LED indicator will illuminate an

Summary of the content on the page No. 10

BYPASS MODE OPERATION During BYPASS operation, mains power provides energy to your load and maintains the batteries in a fully charged state. The four green LED’s indicate an approximate level of load in 25% increments. If the BYPASS becomes loaded beyond full rating, the fifth (amber) LED indicator will illuminate Bypass Mode Operation at and sound an alarm. 51-75% loading The display template indicates the percentage of load on the output. CAUTION: The BYPASS power path does n

Summary of the content on the page No. 11

STARTING THE UPS 1. Ensure the load equipment is turned off, and all loads are properly connected to the UPS output. 2. Check that the mains wall isolator is ON. Turn On (Close) the Battery circuit breaker, the Input and Output circuit breakers in that order. The UPS will now automatically start up and default to BYPASS mode once the UPS is connected to an active AC mains supply and the Battery and Input circuit breakers are closed. At the end of the startup sequence the BYPASS LED sho

Summary of the content on the page No. 12

SWITCHING FROM OUTPUT OFF TO UPS or UPS to BYPASS to OFF 1. If the UPS is in OUTPUT OFF condition, with all rear mounted breakers in the ON position, and the AC input LED and the bottom LED of the BATTERY/LOAD array lit. To go to UPS mode, press the UPS ON/ALARM /BATTERY TEST button until a “Beep” is heard. The UPS will then go through its start-up routine ending up after approximately 10 seconds with the UPS LED lit. 2. If the UPS is operating in UPS mode and there is a need to go to

Summary of the content on the page No. 13

TROUBLESHOOTING The information below indicates various symptoms a user may encounter in the event the UPStation GXT develops a problem. Use this information to determine whether external factors cause the problem and how to remedy the situation. 1. The fault indicator will illuminate indicating the UPS detected a problem. 2. An alarm will sound, alerting that the UPS requires attention. 3. One or more additional load/battery level LED indicators will be illuminated to provide a

Summary of the content on the page No. 14

AUDIBLE ALARM CONDITIONS CONDITION ALARM Battery mode (utility failure) One short beep every ten seconds Low battery Two short beeps every five seconds Output overload (bypass) One short beep every half second Over temperature (bypass) One second beep every four seconds DC Bus over voltage (bypass) One second beep every four seconds PFC failure (bypass) One second beep every four seconds Inverter failure One second beep every four seconds Battery Test failure Two second beep every mi

Summary of the content on the page No. 15

TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTION Fault and Bypass UPS overloaded or load Check load level display and indicators and all load equipment is faulty remove non-essential loads. level LED's are Recalculate load VA and illuminated reduce number of loads connected to UPS. Check load equipment for faults. Fault and Bypass UPS internal fan has a Press Alarm silence button. indicators and problem or UPS Once the temperature is diagnostic LED A are shutdown due to reduced, the UPS

Summary of the content on the page No. 16

UPS MONITORING The UPStation GXT UPS has the capability of being monitored with stand alone computers, network workstations, network servers, or UNIX hosts via the DB-9 socket located on the rear of the UPS. This capability is used in applications requiring the UPS to provide status and power monitoring information to the computer system. For example, during a mains power failure, the information can be used by the computer’s operating system or application program to automatically sav

Summary of the content on the page No. 17

MAINTENANCE The UPStation GXT UPS requires very little maintenance. The batteries are valve regulated, non-spillable, lead acid, and should be kept charged to obtain their designed life. The UPS continuously charges the batteries when connected to the mains supply. When storing the UPS for any length of time, it is recommended to apply power to the UPS for at least 24 hours every four to six months to ensure full recharge of the batteries. In no case should the unit be stored in exces

Summary of the content on the page No. 18

INSTALLATION INSTRUCTIONS These instructions are for use by competent personnel only. INSTALLATION CONSIDERATIONS Detailed instructions to help you install the UPS are provided in the following pages; however, you should give some consideration to the proposed environment in which the UPS is to be installed, and carry out some preparatory work. INSPECTION Before you install the UPS, give it a thorough visual examination to ensure it has not been subjected to shipping damage. If it is

Summary of the content on the page No. 19

OUTPUT INPUT CURRENT AIRFLOW DISSIPATION RATING Amps max 3 Including mains Cfm m h Watts K Btu/hr VA Watts variation/battery charge 130 221 504 1.7 6000 4200 GXT6000 = 33 amps 270 459 840 2.8 10000 7000 GXT10000= 54 amps ELECTRICAL INSTALLATION CONSIDERATIONS This UPS must be installed by competent electrical personnel and wired in accordance with local/national electrical codes. The following information is provided for your guidance. WARNING HIGH EARTH LEAKAGE CURRENT- EARTH C

Summary of the content on the page No. 20

ELECTRICAL CONNECTIONS The UPS is supplied with an input/output/ battery terminal block assembly on the rear of the UPS within a cable box. (see outline drawing) The cable box can be removed to enable knockouts to be removed or new holes drilled, to secure the cables. The cable sizes and distribution methods used during installation are subject to local/ national electrical codes of practice , and therefore are not detailed here. However, table 1 gives details of the input current and th


Alternative user manuals
# User manual Category Download
1 Liebert 130 kVA User manual Power Supply 19
2 Liebert 208V User manual Power Supply 13
3 Liebert 1500 User manual Power Supply 27
4 Liebert 30-130kVA User manual Power Supply 8
5 Liebert 115V User manual Power Supply 8
6 Liebert 230V User manual Power Supply 13
7 Liebert 2U User manual Power Supply 11
8 Liebert 2700VA User manual Power Supply 6
9 Liebert 500-650 VA User manual Power Supply 4
10 Liebert 4000 User manual Power Supply 4
11 Liebert 50 and 60 Hz User manual Power Supply 1
12 Liebert 350-700 VA User manual Power Supply 2
13 Liebert 6000 A User manual Power Supply 7
14 Liebert 600TTM User manual Power Supply 2
15 Liebert 700-2200 VA User manual Power Supply 13
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2