Liebert GXT2-4500RT230 user manual

User manual for the device Liebert GXT2-4500RT230

Device: Liebert GXT2-4500RT230
Category: Power Supply
Manufacturer: Liebert
Size: 3.6 MB
Added : 1/10/2014
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Liebert GXT2-4500RT230. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Liebert GXT2-4500RT230.

For your convenience

If looking through the Liebert GXT2-4500RT230 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Liebert GXT2-4500RT230 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Liebert GXT2-4500RT230 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Liebert GXT2-4500RT230 User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Liebert GXT2-4500RT230 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Liebert GXT2-4500RT230. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

POWER AVAILABILITY
™ ™
GXT2-6000RT230 & GXT2-4500RT230
USER MANUAL
230VAC

Summary of the content on the page No. 2

Summary of the content on the page No. 3

TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 GLOSSARY OF SYMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2.0 SYSTEM DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

8.6 Bypass Indicator LED (Amber) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 8.7 UPS ON Indicator LED (Green) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 8.8 Battery Indicator LED (Amber). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 8.9 AC Input Indicator LED (Green). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 5

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This Manual Contains Important Safety Instructions. Read all safety and operating instructions before operating the Uninterruptible Power Supply (UPS). Adhere to all warnings on the unit and in this manual. Follow all operating and user instructions. This equipment can be operated by individu- als without previous training. This product is designed for Commercial/Industrial use only. It is not intended for use with life sup- port and other

Summary of the content on the page No. 6

GLOSSARY OF SYMBOLS Risk of electrical shock Indicates caution followed by important instructions ! AC input AC output Requests the user to consult the manual i - + Indicates the unit contains a valve-regulated lead acid battery PbH2SO4 R Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage ON/Alarm Silence/Battery Test OFF/Bypass Indicates the position of a fuse 2

Summary of the content on the page No. 7

Introduction 1.0 INTRODUCTION Congratulations on your choice of the Liebert UPStation GXT2-6000RT230 and GXT2-4500RT230 Uninterruptible Power System (UPS). It provides conditioned power to microcomputers and other sensitive electronic equipment. Upon generation, AC power is clean and stable. However, during transmission and distribution it may be subject to voltage sags, spikes, or complete power failure that may interrupt computer opera- tions, cause data loss, or even damage equipment. The

Summary of the content on the page No. 8

System Description 2.0 SYSTEM DESCRIPTION Input Output Dynamic Bypass L1 L1 Rectifier TVSS & /PFC Inverter EMI/RFI DC-to-DC Filters Converter N N Battery Battery Charger G G 2.1 Transient Voltage Surge Suppression (TVSS) and EMI/RFI Filters These UPS components provide surge protection and filter both electromagnetic interference (EMI) and radio frequency interference (RFI). They minimize any surges or interference present in the mains line and keep the sensitive equipment protected. 2.2 R

Summary of the content on the page No. 9

System Description 2.5 DC-to-DC Converter The DC to DC converter utilizes energy from the battery system and raises the DC voltage to the opti- mum operating voltage for the inverter. This allows the inverter to operate continuously at its opti- mum efficiency and voltage, thus increasing reliability. 2.6 Battery The UPStation GXT2 utilizes valve-regulated, nonspillable, lead acid batteries. To maintain battery design life, operate the UPS in an ambient temperature of 20°C to 25°C (68°F to 77°

Summary of the content on the page No. 10

Major Components 3.0 MAJOR COMPONENTS The GXT2 is composed of three major assemblies to provide easier handling, installation, and versa- tility. 3.1 Main Frame and Electronics This 5U cabinet is shipped with internal batteries installed and a basic, hardwire distribution box attached and ready to install. Figure 1 GXT2, front view Top Trim (2 pieces; tower use only) Lower Bezel & Battery Access Door Status Indicators & Controls Upper Bezel 6 ! UPStation GXT

Summary of the content on the page No. 11

Major Components Figure 2 GXT2, rear view Battery Disconnect External Battery Fans Connector UPS Output Circuit Breaker DB-9 Communication REPO Connector Port Relay Card Slot Removable Power Distribution Box Serial Card Slot (SNMP, OCWEB, USB) 3.2 Internal Battery Packs The UPS has two internal battery packs behind a battery access door on the front of the unit. Each pack is fitted with a connector to link to the UPS. Figure 3 Internal battery pack with connector 7

Summary of the content on the page No. 12

Major Components 3.3 Removable Power Distribution Box The UPS arrives with a basic hardwire power distribution pack installed. This box always contains the UPS input circuit breaker. Optional versions may be available to replace the standard box for custom installations. Figure 4 Power distribution boxes, basic, optional Basic Hardwire Power Distribution Box Optional Hardwire Power Distribution PD-CEHDWR Box with Maintenance Bypass Switch PD-CEHDWRBYP NOTE Hardwire and hardwire/receptacle boxe

Summary of the content on the page No. 13

What’s Included 4.0 WHAT’S INCLUDED The GXT2 are shipped with the following items: • GXT2-6000RT230 and GXT2-4500RT230 user manual • Vertical display overlay • Top bezels - 2 • MultiLink software CD • MultiLink serial cable, 10 ft (3m) • Rack mount handles • Support base - 2 • Mounting hardware • Configuration program disk •DB9 port cover Top bezels (tower use) MultiLink software CD MultiLink serial cable 10 ft (3m) Vertical Rack mount display handles www.liebert.com overlay GXT2™ Configurat

Summary of the content on the page No. 14

Installation and Configuration 5.0 INSTALLATION AND CONFIGURATION Do NOT attempt to start the UPS, turn on any circuit breaker or energize the input power until instructed to do so in 6.0 - Initial Start-Up and Electrical Checks. Visually inspect the UPS for freight damage. Report any damage to the carrier and your local dealer or Liebert representative. CAUTION ! The UPS is heavy (see 13.0 - Specifications). Take proper precautions when lifting or moving it. Install the GXT2 indoors in a con

Summary of the content on the page No. 15

Installation and Configuration 5.1.3 Installing the Adjustable Rack-Mount Kit—Sold Separately This kit contains parts needed to mount several different models of UPS and external battery cabi- nets into EIA310-D standard four-post racks that are 18-32" deep (457-813mm). The weight limit per pair of adjustable rack-mounting brackets is 91 kg (200lbs.). Parts included are: Item Quantity Rear bracket members 2 Front bracket members 2 Inner bracket members 2 M4 x 8mm machine screws 16 M4 locking he

Summary of the content on the page No. 16

Installation and Configuration 4. Get eight (8) M4 screws and eight (8) M4 nuts from the M4 nuts M4 screws hardware pack in this kit. Each nut has a locking, nylon insert that begins gripping the screw when it is halfway tight. Make sure to tighten the nut and screw completely to ensure locking action. Fasten the rear member and the front member together using (4) screws and (4) nuts per bracket assembly as shown in at right. For maximum support, insert 457mm fasteners for each bracket a

Summary of the content on the page No. 17

Installation and Configuration 5.2 External Battery Cabinet Installation Optional Liebert external battery cabinets may be connected to the UPS to provide additional battery run time. External battery cabinets are designed to be placed on one side of the UPS or stacked beneath the UPS. CAUTION ! The external battery cabinet(s) are heavy (see 13.0 - Specifications). External battery cabinets can be used in rack-mount or tower configuration. Take proper precautions when lifting them. 1. Visua

Summary of the content on the page No. 18

Installation and Configuration 5.3 Connect the Internal Batteries Using the External Connector The internal connectors of the internal battery packs will be connected when shipped. However, the internal batteries will be disconnected from the UPS using a rear panel connector. The connector attaches to the UPS in both the open and closed position using two screws. The picture on the left shows the connector in the open position, as shipped. When the UPS is installed, remove the two screws to

Summary of the content on the page No. 19

Installation and Configuration Figure 6 Distribution box electrical connections diagram PD-CEHDWR PD-CEHDWRBYP Input Mains Mains Input Byp. Input Input Output 32A Output 32A CB CB External External Inv. 30 30 Branch Branch CB CB UPS UPS Output Output CB CB 30 30 UPS - PFC, Battery, Inverter UPS - PFC, Battery, Inverter PD-CEHDWR and PD-CEHDWRBYP Terminal Block Connections Conduit entry holes are provided on the rear and side of the box. Input and output wiring should not share the same cond

Summary of the content on the page No. 20

Initial Start-Up and Electrical Checks 6.0 INITIAL START-UP AND ELECTRICAL CHECKS 1. Verify that the Input Output circuit breakers are off. 2. During initial system checks, disconnect all loads (open load disconnects). 3. Inspect all wiring, cables, and connection. 4. If external battery cabinets are used, verify that the battery interconnect cables are fully inserted in the sockets. 5. If you are using a distribution box that includes a Manual Bypass Switch, place the switch in BYPASS positi


Alternative user manuals
# User manual Category Download
1 Liebert 130 kVA User manual Power Supply 19
2 Liebert 208V User manual Power Supply 13
3 Liebert 1500 User manual Power Supply 27
4 Liebert 30-130kVA User manual Power Supply 8
5 Liebert 115V User manual Power Supply 8
6 Liebert 230V User manual Power Supply 13
7 Liebert 2U User manual Power Supply 11
8 Liebert 2700VA User manual Power Supply 6
9 Liebert 500-650 VA User manual Power Supply 4
10 Liebert 4000 User manual Power Supply 4
11 Liebert 50 and 60 Hz User manual Power Supply 1
12 Liebert 350-700 VA User manual Power Supply 2
13 Liebert 6000 A User manual Power Supply 7
14 Liebert 600TTM User manual Power Supply 2
15 Liebert 700-2200 VA User manual Power Supply 13
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2