Liebert 700-2200 VA user manual

User manual for the device Liebert 700-2200 VA

Device: Liebert 700-2200 VA
Category: Power Supply
Manufacturer: Liebert
Size: 2.82 MB
Added : 1/10/2014
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Liebert 700-2200 VA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Liebert 700-2200 VA.

For your convenience

If looking through the Liebert 700-2200 VA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Liebert 700-2200 VA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Liebert 700-2200 VA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Liebert 700-2200 VA User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Liebert 700-2200 VA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Liebert 700-2200 VA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

POWER PROTECTION
R
PowerSure™ Interactive
700-2200 VA
120 V
USER MANUAL
English

Summary of the content on the page No. 2

IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to service this product yourself except to replace the battery. Opening or removing the cover may expose you to dangerous voltages, even when the AC cord is disconnected from the electrical outlet. Refer all servicing to qualified service personnel. 1. SAVE THESE INSTRUCTIONS. THIS MANUAL CONTAINS IMPORTANT INSTRUCTIONS THAT SHOULD BE FOLLOWED DURING INSTALLATION AND MAINTENANCE OF THE UNINTERRUPTIBLE POWER SYSTEM (UPS) AND BATTERIES. CONS

Summary of the content on the page No. 3

it, or the safety ground will be removed. Operate UPS only from a properly grounded 120 VAC outlet (2 wire plus ground). 9. The UPS is equipped with a grounded NEMA 5-15P or L5-30P input power plug (depending upon model). Do not defeat the safety purpose of this plug. If unable to fully insert the plug into the wall outlet, contact a qualified electrician for assistance. 10. Route power supply cords so they are not walked on or pinched. 11. Never block or insert any object into the ventilatio

Summary of the content on the page No. 4

INTRODUCTION & SYSTEM DESCRIPTION Congratulations on your choice of the Liebert PowerSure™ Interactive Uninterruptible Power System (UPS). It provides conditioned power to microcomputers and other sensitive electronic equipment. Upon generation, AC power is clean and stable. However, during transmission it may be subject to voltage sags, spikes, or complete power failure which may interrupt computer operations, cause data loss, or even damage equipment. The PowerSure™ Interactive protects equ

Summary of the content on the page No. 5

MAJOR COMPONENTS TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) AND EMI/RFI FILTERS These UPS components provide surge protection and filter Electromagnetic Interference (EMI) and Radio Frequency Interference (RFI). They minimize any surges or interference present in the utility line and keep the sensitive equipment protected. AUTOMATIC VOLTAGE REGULATOR In normal operation, the Automatic Voltage Regulator (AVR) passes utility AC power to the connected load. When utility power voltage is outside a

Summary of the content on the page No. 6

MINI-TOWER INSTALLATION 1. Unpack the UPS carefully noting the packing method. Retain the box and packing material for possible future shipment. CAUTION: The UPS is heavy (see specifications). Take proper precautions when lifting or moving it. 2. Visually inspect the UPS for freight damage. Report damage to the carrier and your dealer. 3. Locate the UPS indoors where it cannot be accidentally disconnected. Locate it in an area with unrestricted airflow, away from water, flammable liquids, ga

Summary of the content on the page No. 7

RACKMOUNT INSTALLATION 1. Unpack the UPS carefully noting the packing method. Retain box and packing material for possible future shipment. CAUTION: The UPS is heavy (see specifications). Take the proper precautions when lifting or moving the UPS. 2. Visually inspect the UPS for freight damage. Report any damage to the carrier and your dealer. 3. Locate the UPS indoors where it cannot be accidentally disconnected. Locate it in an area with unrestricted airflow, away from water, flammable li

Summary of the content on the page No. 8

CONTROLS AND INDICATORS On/Off Button The On/Off button controls output power to connected load(s). CAUTION: Pressing the On/Off button when AC utility is not present will cause the UPS to begin operating from battery. This should not be performed unless the UPS input is connected to a properly grounded receptacle. Load/Battery Level Indicators (ALL GREEN) The Load/Battery Level Indicators have dual functions. During normal mode operation, LED indicators display electrical load placed upon th

Summary of the content on the page No. 9

POWERSURE™ INTERACTIVE MINI-TOWER Fault Indicator Load/Battery Utility High/Low Level Indicators Indicator Alarm Silence/ Utility/Battery Battery Test Button Status Indicator On/Off Button 1- Output Receptacles 2- DB-9 Interface Port 1 3- AC Inlet 4- Intellislot™ Communications Port 5- Circuit Protector or Fuse 2 6- Site Wiring Fault Indicator 2 64 4 26 1 5 5 1 5 3 4 3 6 1 3 700 VA 1000 / 1400 VA 2200 VA 9

Summary of the content on the page No. 10

POWERSURE™ INTERACTIVE RACKMOUNT Utility High / Low Indicator Fault Indicator Load / Battery Utility/ Battery Level Indicators Status Indicator R Load / Battery Utility High / Low Utility Alarm Silence On / Off Alarm Silence / On / Off Button Battery Test Button 2200 Model 5 5 1 3 6 1 62 5 3 4 700-1400 Models *700 Model has detachable cord 1- Output Receptacles 2- DB-9 Interface Port 3- AC Inlet 4- Intellislot™ Communications Port 5- Circuit Protector or Fuse 6- Site Wiring Fault Indicator 10

Summary of the content on the page No. 11

OPERATION NORMAL MODE OPERATION During normal operation, utility power provides energy to the UPS. The filters and the power conditioning circuit process this power to provide computer grade power to connected loads. The UPS maintains the batteries in a fully charged state. The front panel displays the percentage of load on the UPS output. The figure below indicates approximately 51-75% loading. 76% to 100% load (Flashes to indicate overload) Load/ Battery 51% to 75% load Level Indicators 26%

Summary of the content on the page No. 12

BATTERY MODE OPERATION Battery mode occurs in event of extreme input conditions or complete utility failure. The battery system along with the bi-directional converter generates power for the connected load. During battery mode an alarm sounds every 10 seconds. This will change to 2 beeps every 5 seconds when battery runs low (approximately 2 minutes remaining). Each load/battery level indicator represents a 25% capacity level. As capacity decreases, fewer indicators remain illuminated. Util

Summary of the content on the page No. 13

COMMUNICATIONS INTERFACE PORT The PowerSure™ Interactive UPS contains a standard DB-9F recepticle located on the rear of the UPS unit. Several signals are provided on this port and are assigned as follows: PIN ASSIGNMENT DESCRIPTION 1 Low Battery (open collector) 2 UPS TxD (typical RS-232 levels) 3 UPS RxD (typical RS-232 levels) 4 Remote Shutdown (5-12V DC, 1.0 mA. max.); battery operation 5 Common 6 No connection 7 Low Battery (open emitter) 8 Utility Fail (open emitter) 9 Utility Fail (open

Summary of the content on the page No. 14

UPS INTELLIGENT COMMUNICATIONS The PowerSure™ Interactive UPS has the capability to communicate intelligently with stand alone computers, network workstations, network servers, or UNIX hosts via the DB-9 female connector located on the rear of the UPS. By purchasing the optional Liebert SiteNet® 2 software package (sold separately), intelligent communications allows the following capabilities: • Quantitative monitoring of utility and UPS power • Quantitative monitoring of internal UPS parameters

Summary of the content on the page No. 15

MINI-TOWER BATTERY REPLACEMENT CAUTION- A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed before replacing the batteries: • Turn off and disconnect the UPS from utility power prior to opening the battery replacement door. • Remove rings, watches, and other metal objects. • Use a Phillips (cross head) screwdriver with insulated grips. • Do not lay tools or other metal objects on top of the batteries. • If the battery rep

Summary of the content on the page No. 16

MINI-TOWER BATTERY REPLACEMENT Pull bezel forward Rotate bezel on top Remove battery door 700 VA Model To Disconnect: Gently pull wiring away To Connect: Connect red wire to red terminal, then black wire to black terminal by pushing towards connector 1000/1400 VA Model To Disconnect: Gently pull wiring away To Connect: Connect red wire to red terminal, then black wire to black terminal by pushing upward 2200 VA Model A B To Disconnect: Pull apart connections A & B To Con

Summary of the content on the page No. 17

RACKMOUNT BATTERY REPLACEMENT CAUTION- A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed before replacing the batteries: • Turn off and disconnect the UPS from utility power prior to opening the battery replacement door. • Remove rings, watches, and other metal objects. • Use a Phillips (cross head) screwdriver with insulated grips. • Do not lay tools or other metal objects on top of the batteries. • If the battery repl

Summary of the content on the page No. 18

Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 7 Figure 6 18

Summary of the content on the page No. 19

TROUBLESHOOTING The information below indicates various symptoms a user may encounter in the event the PowerSure™ Interactive UPS develops a problem. Use this information to determine whether external factors cause the problem and how to remedy the situation. 1. The fault indicator will flash every second to indicate the UPS detected a problem. 2. An alarm will sound, alerting that the UPS requires attention. 3. One or more additional load/battery level LED segments will be illuminated to provi

Summary of the content on the page No. 20

TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTION UPS fails to start when On/Off UPS output short circuited or Ensure UPS is off. Disconnect all button is pressed overloaded. loads and ensure nothing is lodged in output receptacles. Ensure loads are not defective or shorted internally. Internal fuse is blown, indicating Do not attempt to open or service internal fault. the UPS. Contact your dealer or LTS. Utility indicator flashing UPS not plugged in. UPS is operating in battery mode, make certain


Alternative user manuals
# User manual Category Download
1 Liebert 130 kVA User manual Power Supply 19
2 Liebert 208V User manual Power Supply 13
3 Liebert 1500 User manual Power Supply 27
4 Liebert 30-130kVA User manual Power Supply 8
5 Liebert 115V User manual Power Supply 8
6 Liebert 230V User manual Power Supply 13
7 Liebert 2U User manual Power Supply 11
8 Liebert 2700VA User manual Power Supply 6
9 Liebert 500-650 VA User manual Power Supply 4
10 Liebert 4000 User manual Power Supply 4
11 Liebert 50 and 60 Hz User manual Power Supply 1
12 Liebert 350-700 VA User manual Power Supply 2
13 Liebert 6000 A User manual Power Supply 7
14 Liebert 600TTM User manual Power Supply 2
15 Liebert GXT2 - 3X1 User manual Power Supply 27
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2