Liebert 600TTM user manual

User manual for the device Liebert 600TTM

Device: Liebert 600TTM
Category: Power Supply
Manufacturer: Liebert
Size: 3.2 MB
Added : 1/10/2014
Number of pages: 91
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Liebert 600TTM. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Liebert 600TTM.

For your convenience

If looking through the Liebert 600TTM user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Liebert 600TTM on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Liebert 600TTM to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Liebert 600TTM User manual - Online PDF
Advertisement
« Page 1 of 91 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Liebert 600TTM but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Liebert 600TTM. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

POWER PROTECTION
Series 600T™ UPS
Multi-Module Three Phase
500 kVA to 750 kVA, 60 Hz
Installation
Manual

Summary of the content on the page No. 2

The following WARNING applies to all battery cabinets supplied with UPS systems: WARNING HAZARD INTERNAL BATTERY STRAPPING MUST BE VERIFIED BY MANU- FACTURER PRIOR TO MOVING A BATTERY CABINET. Battery cabinets contain non-spillable batteries. Keep units upright. Do not stack. Do not tilt. Failure to heed this warning could result in smoke, fire or electric hazard. Call 1-800-LIEBERT prior to moving battery cabinets.

Summary of the content on the page No. 3

Table of Contents 1.0 SAFETY PRECAUTIONS ...... ....... ...... ...... ....... ...... ....... ...... ....... ... 3 2.0 INSTALLATION CONSIDERATIONS..... ...... ...... ....... ...... ....... ...... ....... ... 4 2.1 Types of System Control Cabinets .. ...... ....... ...... ....... ...... ....... ... 6 3.0 UNLOADING AND HANDLING . ....... ...... ...... ....... ...... ....... ...... ....... ... 7 4.0 INSPECTIONS 4.1 External Inspections ....... ...... ...... ....... ...... ....... ...... ....... ...

Summary of the content on the page No. 4

Summary of the content on the page No. 5

List of Figures Figure1 UPS Multi-ModuleUnit BlockDiagram. ...... ....... ...... ....... ...... ....... ... 5 Figure 2 SystemControl Cabinets ....... ...... ...... ....... ...... ....... ...... ....... ... 6 Figure 3 Preferred Grounding Configuration,480or 600VAC Input and Output. ...... ....... .. 15 Figure 4 Grounding Configuration with Ungrounded Delta Source Input ....... ...... ....... .. 16 Figure 5 Preferred Grounding Configuration,Power-Tie Systems ...... ....... ...... ....... .. 17 Fig

Summary of the content on the page No. 6

Figure 48 Option Wiring,Battery TemperatureSensor ...... ....... ...... ....... ...... ...... 69 Figure49 Option Wiring,SNMP Interface .... ...... ...... ....... ...... ....... ...... ...... 70 Figure 50 External Interconnections,Module1/SCC,Cable Groups 21and 22 ....... ...... ...... 71 Figure 51 External Interconnections,Module2/SCC,Cable Groups 21and 22 ....... ...... ...... 72 Figure 52 Wiring Configurations, UPS VideoDisplay Terminal ...... ...... ....... ...... ...... 73 Figure 53 Module B

Summary of the content on the page No. 7

IMPORTANT SAFETY INSTRUCTIONS Save These Instructions. This manual contains important instructions that should be followed during installation of your Series 600T UPS and batteries. WARNING EXERCISE EXTREME CARE WHEN HANDLING UPS CABINETS TO AVOID EQUIPMENT DAMAGE OR INJURY TO PERSONNEL. THE UPS MODULE WEIGHT RANGES UP TO 12,000 POUNDS (5,455 KG), INCLUDING INPUT TRANSFORMER. THE BATTERY CABINETS WEIGH BETWEEN 3000 POUNDS (1364 KG) AND 4900 POUNDS (2227 KG). LOCATE CENTER OF GRAVITY SYMBOLS BE

Summary of the content on the page No. 8

WARNING LOCATE CENTER OF GRAVITY SYMBOLS AND DETERMINE UNIT WEIGHT BEFORE HANDLING CABINET. If you require assistance for any reason, call the toll-free Liebert Global Services number; 1-800- 543-2378. For LGS to assist you expediently, please have the following information available: Part Numbers: ______________________________________________________________ Serial Numbers: ______________________________________________________________ kVA Rating: ____________________________________________

Summary of the content on the page No. 9

1.0 SAFETY PRECAUTIONS Read this manual thoroughly, paying special attention to the sections that apply to you, before working with the UPS. Retain this manual for use by installing personnel. Under typical operation and with all UPS doors closed, only normal safety precautions are neces- sary. The area around the UPS system should be kept free from puddles of water, excess mois- ture, or debris. Special safety precautions are required for procedures involving handling, installation, and main- t

Summary of the content on the page No. 10

2.0 INSTALLATION CONSIDERATIONS Install your Series 600T UPS in accordance with the submittal drawing package and the follow- ing procedures. A Liebert authorized representative must perform the initial system check-out and start-up to ensure proper system operation. Equipment warranties will be voided unless system start-up is performed by a Liebert authorized representative. Contact your local Liebert sales representative or Liebert Global Services at 1-800-543-2378 to arrange for system start

Summary of the content on the page No. 11

Figure 1 UPS Multi-Module Unit Block Diagram Installation Considerations 5

Summary of the content on the page No. 12

Figure 2 System Control Cabinets SCCT Dimensions Amp WxD Weight Ratings (Inches) (lbs.) 200-1200 37x37 1000 1600 62x48 1525 2000-2500 62x48 2850 3000 62x48 3100 4000 138x60 5850 2.1 Types of System Control Cabinets 1. SCCT is a stand-alone cabinet containing system control logic for up to six UPS modules, static bypass switch, manually operated disconnects for the static bypass switch, and two motor-operated system breakers. The SCCT is painted the same color as the Liebert UPS, but does not mat

Summary of the content on the page No. 13

3.0 UNLOADING AND HANDLING The UPS module is shipped in one cabinet to allow easy handling at the site. Because the weight distribution in the cabinet is uneven, use extreme care during handling and transport. Your installation may also include Battery Cabinets and a System Control Cabinet. WARNING EXERCISE EXTREME CARE WHEN HANDLING UPS CABINETS TO AVOID EQUIPMENT DAMAGE OR INJURY TO PERSONNEL. THE UPS MODULE WEIGHS UP TO 12,000 POUNDS. BATTERY CABINETS WEIGH BETWEEN 3100 AND 4900 POUNDS. LOC

Summary of the content on the page No. 14

4.0 INSPECTIONS 4.1 External Inspections 1. While the UPS system is still on the truck, inspect the equipment and shipping container(s) for any signs of damage or mishandling. Do not attempt to install the system if damage is apparent. If any damage is noted, file a damage claim with the shipping agency within 24 hours and contact Liebert Global Services at 1-800-543-2378 to inform them of the damage claim and the condition of the equipment. 2. Locate the bag containing the keys for the front ac

Summary of the content on the page No. 15

5.0 EQUIPMENT LOCATION 1. Handle cabinet(s) in accordance with the Section 1.0 Safety Precautions and 3.0 Unloading & Handling. Use a suitable material handling device to move cabinet to its final location. Exercise extreme care because of the uneven weight distribution. Carefully lower the cabinet to the floor. 2. Verify that the UPS system is installed in a clean, cool and dry location. 3. Installation and serviceability will be easier if adequate access is provided on all sides of the equipme

Summary of the content on the page No. 16

6.0 BATTERY INSTALLATION 6.1 Battery Safety Precautions Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, use the same number and type of batteries. CAUTION Lead-acid batteries contain hazardous materials. Batteries must be handled, transported, and recycled or discarded in accordance with federal, state, and local regulations. Because lead is

Summary of the content on the page No. 17

Battery Safety Precautions in French Per CSA Requirements Instructions Importantes Concernant La Sécurité Conserver Ces Instructions ADVERTISSEMENT DES PIECES SOUS ALIMENTATION SERONT LAISSEES SANS PROTECTION DURANT CES PROCEDURES D’ENTRETIEN. UN PERSONNEL QUALIFIE EST REQUIS POUR EFFECTUER CES TRAVAUX. LES FUSIBLES A C.C. DE LA BATTERIE D’ACCUMULATEURS OPERENT EN TOUT TEMPS A LA TENSION NOMINALE. LA PRESENCE D’UN FUSIBLE A C.C. BRULE INDIQUE UN PROBLEME SERIEUX. LE REMPLACEMENT DE CE FUSIBLE,

Summary of the content on the page No. 18

Les accumulateurs plomb-acide présentent un risque d’incendie parce qu’ils génèrent des gaz à l’hydrogène. Les procédures suivantes devront être respectées. 1. NE PAS FUMER lorsque près des accumulateurs. 2. NE PASproduiredeflammesou d’étincellesprèsdes accumulateurs. 3. Décharger toute électricité statique présente sur votre corps avant de toucher un accumulateur en touchant d’abord une surfacemétalliquemiseàlaterre. DANGER L’électrolyte est un acide sulfurique dilué qui est dangereux au cont

Summary of the content on the page No. 19

6.2 Matching Battery Cabinets Two sizes of optional battery cabinets are available. Refer to Figure 16 to Figure 18. The battery cabinet cells range from 90 to 150 Ampere-hours. The same model battery cabinet may be paral- leled in multiple cabinet strings for additional capacity. Battery capacity (in minutes) at your installation will depend on cabinet model, number of cabinets, and amount of critical load on the UPS. 1. Handling. The Battery Cabinet weighs 3000 to 4900 pounds. Forklift slots a

Summary of the content on the page No. 20

7.0 CONFIGURING YOUR NEUTRAL AND GROUND CONNECTIONS Improper grounding is the largest single cause of UPS installation and start-up problems. This is not an easy subject, since grounding techniques vary significantly from site to site, depending on several factors. The questions you should ask are:  What is the configuration of the input power source? Most of the recommended schemes for UPS grounding require grounded-wye service. The UPS system requires a bypass neutral for sensing and monitori


Alternative user manuals
# User manual Category Download
1 Liebert 130 kVA User manual Power Supply 19
2 Liebert 208V User manual Power Supply 13
3 Liebert 1500 User manual Power Supply 27
4 Liebert 30-130kVA User manual Power Supply 8
5 Liebert 115V User manual Power Supply 8
6 Liebert 230V User manual Power Supply 13
7 Liebert 2U User manual Power Supply 11
8 Liebert 2700VA User manual Power Supply 6
9 Liebert 500-650 VA User manual Power Supply 4
10 Liebert 4000 User manual Power Supply 4
11 Liebert 50 and 60 Hz User manual Power Supply 1
12 Liebert 350-700 VA User manual Power Supply 2
13 Liebert 6000 A User manual Power Supply 7
14 Liebert 700-2200 VA User manual Power Supply 13
15 Liebert GXT2 - 3X1 User manual Power Supply 27
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2