Liebert 2U user manual

User manual for the device Liebert 2U

Device: Liebert 2U
Category: Power Supply
Manufacturer: Liebert
Size: 0.98 MB
Added : 1/10/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Liebert 2U. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Liebert 2U.

For your convenience

If looking through the Liebert 2U user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Liebert 2U on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Liebert 2U to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Liebert 2U User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Liebert 2U but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Liebert 2U. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

POWER AVAILABILITY

2UPOD
USER MANUAL
Power Output
Distribution
230 Volt

Summary of the content on the page No. 2

Summary of the content on the page No. 3

TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 GLOSSARY OF SYMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 INTRODUCTION AND SYSTEM DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Summary of the content on the page No. 4

Summary of the content on the page No. 5

IMPORTANT SAFETY INSTRUCTIONS WARNING ! DO NOT ATTEMPT TO SERVICE THIS PRODUCT YOURSELF. OPENING OR REMOVING THE COVER MAY EXPOSE YOU TO DANGEROUS VOLTAGES, EVEN WHEN THE AC CORD IS DISCONNECTED FROM THE ELECTRICAL SOCKET. REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL. SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and ™ operation of the 2U POD . This product is designed for commercial / industrial use only, with Lieber

Summary of the content on the page No. 6

GLOSSARY OF SYMBOLS • Indicates AC Input. Indicates AC Output. Consult the manual for additional information. i MAINS lamp indicates local power is available and the load may be MAINS transferred to bypass the UPS. UPS lamp indicates UPS power is available and the load may be UPS transferred to the UPS to provide computer-grade power to the load. 2

Summary of the content on the page No. 7

INTRODUCTION AND SYSTEM DESCRIPTION ™ Congratulations on your choice of the Liebert 2U POD . The Liebert 2U POD provides main- tenance bypass capability as well as power output distribution. The Liebert 2U POD can be used on UPSs in the rack mount or tower configuration. The Liebert 2U POD provides an isolated path of power for your UPS system for preventive maintenance or service. System Description The 2U POD has two modes of operation: UPS (UPS available) and MAINS (maintenance bypass).

Summary of the content on the page No. 8

INSTALLATION ON GXT 2U UPS NOTE This manual provides instructions for the 2U POD only. Refer to your UPS manual for UPS operation and installation instructions. 1. Unpack the 2U POD carefully, noting the packing method. Retain the box and packing material for possible future shipments. 2. Visually inspect the 2U POD for freight damage. Report damage to the carrier and your local dealer or Liebert representative. 3. Verify that the 2U POD input cord, UPS input cord, and socket for the UPS ar

Summary of the content on the page No. 9

6. Next attach the POD to the securing brackets (see Figure 5). The POD can be installed to face one of three different directions utilizing the same mounting procedures. Figure 5 Attaching POD to securing brackets 7. Make sure the 2U POD rotary switch is in the MAINS position. Use the mains input cord originally used with the UPS. Plug the mains input cord from the mains input socket to the mains wall socket. WARNING: The 2U POD is now electrically live. The MAINS lamp (orange) should now

Summary of the content on the page No. 10

RACK MOUNT INSTALLATION 1. Rack mount installation of the 2U POD is possible with the use of the rack mounting brackets (shipped with the POD). See Figure 6. 2. The rack mount brackets allow you to rack mount the POD in a 19" enclosure (23" to 19" rack adapters would have to purchased separately if you are using our 23" Foundation or equivalent cabinet). 3. The POD can be mounted to face one of four directions depending on your application, and utilizing the rack mount brackets provided. 4

Summary of the content on the page No. 11

INDICATOR LAMPS MAINS Indicator Lamp This orange lamp is illuminated when mains power is present (see Figure 7). It signals that you may transfer the loads to maintenance bypass (MAINS mode) operation via the rotary switch. During a mains power outage, this lamp will be off and the UPS will supply battery back-up power to the connected loads. UPS Indicator Lamp This green lamp is illuminated when there is output power available from the UPS (see Figure 7). It signals that it is safe to tra

Summary of the content on the page No. 12

OPERATION Transfer to Maintenance Bypass To transfer to maintenance bypass (mains) from UPS, use the following steps: 1. Ensure the MAINS lamp (orange) is illuminated. If the lamp is not illuminated, refer to Troubleshooting section. 2. Transfer the rotary switch from UPS to MAINS, provided the MAINS lamp is illuminated on the 2U POD. 3. Turn the UPS off. 4. Disconnect the two cables connecting the UPS to the 2U POD. 5. You may now service the UPS. Transfer to UPS To transfer to UPS from m

Summary of the content on the page No. 13

SPECIFICATIONS Transfer Time (to and from maintenance bypass) < 6 milliseconds Operating Ambient Temperature 0°C to +40°C (32°F to 104°F) Storage Ambient Temperature -20°C to +60°C (-4°F to 140°F) Dimensions W x D x H: mm (in.) 88 x 77 x 394 (3.5 x 3.0 x 15.5) Weight: kg (lbs) 4.5 (10) Humidity 0 to 95% non-condensing Agency/Standards CE, EN 60950, ISTA Procedure 1A Electrical Rating See Model Label on MicroPOD This 2U POD is intended for use with a UPS meeting all the following requirements:

Summary of the content on the page No. 14

TROUBLESHOOTING Problem Cause Solution MAINS lamp (orange) not Mains not present. Call qualified service personnel to restore illuminated. power to socket. 2U POD input cord not Refer to 2U POD installation instructions in connected to mains. this manual: • Installation on GXT 2U UPS and • Rack Mount Installation. UPS Available lamp (green) not UPS output power not Turn on UPS. Refer to UPS user manual. illuminated. present. UPS input and/or output cord Refer to 2U POD installation instruct

Summary of the content on the page No. 15

Summary of the content on the page No. 16

POWER AVAILABILITY ™ 2UPOD USER MANUAL Technical Support The Company Behind the Products United States With over a million installations around the globe, 1050 Dearborn Drive Liebert is the world leader in computer protection P.O. Box 29186 systems. Since its founding in 1965, Liebert has Columbus, OH 43229 developed a complete range of support and protection systems for sensitive electronics: Single-Phase UPS • Environmental systems—close-control air 800-222-5877 conditioning from 1 to 60 tons


Alternative user manuals
# User manual Category Download
1 Liebert 130 kVA User manual Power Supply 19
2 Liebert 208V User manual Power Supply 13
3 Liebert 1500 User manual Power Supply 27
4 Liebert 30-130kVA User manual Power Supply 8
5 Liebert 115V User manual Power Supply 8
6 Liebert 230V User manual Power Supply 13
7 Liebert 2700VA User manual Power Supply 6
8 Liebert 500-650 VA User manual Power Supply 4
9 Liebert 4000 User manual Power Supply 4
10 Liebert 50 and 60 Hz User manual Power Supply 1
11 Liebert 350-700 VA User manual Power Supply 2
12 Liebert 6000 A User manual Power Supply 7
13 Liebert 600TTM User manual Power Supply 2
14 Liebert 700-2200 VA User manual Power Supply 13
15 Liebert GXT2 - 3X1 User manual Power Supply 27
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2