Furuno M51A user manual

User manual for the device Furuno M51A

Device: Furuno M51A
Category: Power Supply
Manufacturer: Furuno
Size: 0.41 MB
Added : 8/10/2013
Number of pages: 22
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Furuno M51A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Furuno M51A.

For your convenience

If looking through the Furuno M51A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Furuno M51A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Furuno M51A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Furuno M51A User manual - Online PDF
Advertisement
« Page 1 of 22 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Furuno M51A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Furuno M51A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1






DLM 600W Series
Power Supplies
M51A Option: Isolated Analog
Programming Manual


Power Supplies

Elgar Electronics Corporation
9250 Brown Deer Road
San Diego, CA 92121-2294
1-800-73ELGAR (1-800-733-5427)
Tel: (858) 450-0085
Fax: (858) 458-0267
Email: sales@elgar.com
www.elgar.com
©2002 by Elgar Electronics Corporation
This document contains information proprietary to Elgar Electronics Corporation. The information contained herein is
not to be duplicated or transfer

Summary of the content on the page No. 2

.

Summary of the content on the page No. 3

SAFETY NOTICE Before applying power to the system, verify that the instrument is configured properly for the user’s particular application. WARNING! Hazardous voltages may be present when covers are removed. Qualified personnel must use extreme caution when servicing this equipment. Circuit boards, test points, and output voltages also may be floating with respect to chassis ground. Installation and servicing must be performed by qualified personnel who are aware of dealing pr

Summary of the content on the page No. 4

SAFETY SYMBOLS ii

Summary of the content on the page No. 5

ELGAR FIVE–YEAR WARRANTY Elgar Electronics Corporation (hereinafter referred to as Elgar) warrants its products to be free from defects in material and workmanship. This warranty is effective for one year from the date of shipment of the product to the original purchaser. Liability of Elgar under this warranty shall exist provided that: • the Buyer exposes the product to normal use and service and provides normal maintenance on the product; • Elgar is promptly notified of defects by the

Summary of the content on the page No. 6

This page intentionally left blank. iv

Summary of the content on the page No. 7

CONTENTS SECTION 1 M51A OPTION OVERVIEW 1.1 Introduction...................................................................................................... 1-1 1.2 General Description......................................................................................... 1-1 1.3 Specifications................................................................................................... 1-2 1.3.1 Electrical Specifications.........................................................

Summary of the content on the page No. 8

Contents DLM 600W Series LIST OF TABLES Table 2–1. INTFC SETUP Switch............................................................................... 2-1 Table 2–2. ISOLATED ANALOG INTERFACE Connector Pinout .............................. 2-4 Table 2–3. Remote Programming Configuration Options ........................................... 2-7 Table 2–4. Remote Monitoring................................................................................. 2-11 Table 2–5. Remote Digital Sta

Summary of the content on the page No. 9

SECTION 1 M51A OPTION OVERVIEW 1.1 Introduction This addendum is to be used in conjunction with the DLM 600W Series Power Supplies Operation Manual, Sorensen Document No. M362161-01. The Sorensen M51A Option for the DLM 600W Series power supplies provides a remote analog interface, which has safety isolation from the output terminals. This allows the remote analog interface to be connected to user accessible (SELV) control circuits, even though the output terminals were floated at a

Summary of the content on the page No. 10

M51A Option Overview DLM 600W Series 1.3 Specifications 1.3.1 Electrical Specifications Remote Voltage Programming Accuracy, 0-5/10V Inputs: Output Voltage: 0.5% of Vmax Output Current: 0.75% of Imax OVP: 1.0% of 1.1 X Vmax Remote 4-20mA Programming Accuracy: Output Voltage: 0.75% of Vmax Output Current: 1.0% of Imax 1.3.2 Supplemental Characteristics Remote Resistance Programming Accuracy, 0-5k Ω Input: Output Voltage: 1.0% of Vmax Output Current: 1.5% of Imax OV

Summary of the content on the page No. 11

SECTION 2 ISOLATED REMOTE ANALOG INTERFACE OPERATION 2.1 INTFC SETUP Switch The INTFC SETUP (Interface Setup) switch is accessible from the rear panel of the unit. It provides user selectability of the programming/monitoring ranges and signal types, as well as configuring the power supply for operation under remote control. Setting a switch to the UP position enables a function. The factory default settings are all switch positions OFF (down). See Figure 2–1 for a rear panel view

Summary of the content on the page No. 12

Isolated Remote Analog Interface Operation DLM 600W Series 2.1.1 INTFC SETUP Switch Functions The following sections describe the functions of the various switch positions: V, 10V or 4-20mA Select: Position-1, when ON, selects 0-10VDC programming of the output voltage. Also, must be set to ON position when the ISOLATED ANALOG INTERFACE connector is wired for 4-20mA output voltage programming. When OFF, selects 0-5VDC programming of the output voltage. I, 10V or 4-20mA Select: P

Summary of the content on the page No. 13

DLM 600W Series Isolated Remote Analog Interface Operation Figure 2–1. Rear Panel View, Low–Voltage Models Figure 2–2. Rear Panel View, High–Voltage Models M51A Option 2-3

Summary of the content on the page No. 14

Isolated Remote Analog Interface Operation DLM 600W Series 2.3 Isolated Analog Interface Connector The ISOLATED ANALOG INTERFACE connector is a 25-position female Subminiature-D type. Pin Function 1 ANALOG-CONTROL input 2 Return for 0-5/10V monitor outputs and EXTERNAL-OFF 3 OVP programming input 4 Voltage monitor output, 4-20mA 5 VOLTAGE-MODE status output 6 Return for 4-20mA monitor outputs, Auxiliary 5VDC, and digital I/O 7 Current monitor output, 0-5/10V 8 1.25VDC output for

Summary of the content on the page No. 15

DLM 600W Series Isolated Remote Analog Interface Operation 2.3.1 ISOLATED ANALOG INTERFACE Functions The following sections describe the functions of the various signals of the ISOLATED ANALOG INTERFACE. Pin numbers correspond to the connector pinout of Table 2–2. Digital Control Input Signals ANALOG-CONTROL: Pin-1, enables remote analog programming with an active-high logic level of 3-15VDC. An internal 100k Ω pull-down resistor is provided. When ANALOG- CONTROL is asserted, the

Summary of the content on the page No. 16

Isolated Remote Analog Interface Operation DLM 600W Series Analog Programming Signals OVP PROGRAMMING INPUT: Pin-3, an input signal of 0-5 volts or 0-10 volts (user selectable with INTFC SETUP switch) programs the OVP threshold from 5-110% of full scale output voltage. Signal is referenced to Pin-12. Circuit is SELV, and has electrical isolation from the output of the unit. VOLTAGE PROGRAMMING INPUT: Pin-9, an input signal for two methods of programming the output voltage: 0-5/10V v

Summary of the content on the page No. 17

DLM 600W Series Isolated Remote Analog Interface Operation CURRENT RESISTANCE PROGRAMMING OUTPUT: Pin-22 provides a 1mA current source which would be connected to Pin-10, CURRENT PROGRAMMING INPUT, with a 0-5k Ω external resistor connected between Pin-22 to Pin-12, to program the output current from 0-100% of full scale output. The INTFC SETUP switch Position-2, I, must be set to OFF (down) to select 0-5VDC input range. Circuit is SELV, and has electrical isolation from the output of the

Summary of the content on the page No. 18

Isolated Remote Analog Interface Operation DLM 600W Series 2.4.1 Voltage Source Programming of Output Voltage Setting up for voltage source programming of the output voltage is as follows: 1. Set Position-1, V, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming range. 2. Set Position-1, V, of the INTFC SETUP switch ON (up) for 0-10VDC programming range. 3. Connect the external programming voltage source to the ISOLATED ANALOG INTERFACE connector, with positive to Pin

Summary of the content on the page No. 19

DLM 600W Series Isolated Remote Analog Interface Operation 4. Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING INPUT, Pin-9, and the CURRENT PROGRAMMING INPUT, Pin-10, with respect to Pin-12. 5. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE connector to Pin-15. 2.4.4 Resistance Programming of Output Voltage Setting up for resistance programming of the output voltage is as follows: 1. Set Position-1, V, of the INTFC SETUP switch to O

Summary of the content on the page No. 20

Isolated Remote Analog Interface Operation DLM 600W Series 2.4.6 Resistance Programming of OVP Setting up for resistance programming OVP is as follows: 1. Set Position-3, OVP, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming range. 2. Connect the external programming resistance, 0-5k Ω, to the ISOLATED ANALOG INTERFACE connector, from Pin-16 to Pin-12. 3. Connect a jumper from Pin-16 to Pin-3. 4. Program the other parameters to the desired limit values: VOLTAGE


Alternative user manuals
# User manual Category Download
1 Furuno RS-600-ASAA User manual Power Supply 5
2 Furuno M51A User manual Power Supply 2
3 Furuno RS-600-ASAA User manual Power Supply 8
4 Sony AC U50A User manual Power Supply 5
5 Sony AC LS1 User manual Power Supply 2
6 Sony NP-FM30 User manual Power Supply 35
7 Sony NP FX101 User manual Power Supply 1
8 Sony NH-AAA-DA User manual Power Supply 2
9 3Com 3645A User manual Power Supply 0
10 3Com 3CNJPSE24 User manual Power Supply 2
11 3Com COREBUILDER 5000 User manual Power Supply 0
12 3Com 3646A User manual Power Supply 0
13 3Com External PoE Power System PSE2500-A3 User manual Power Supply 1
14 Sony AC E45HG User manual Power Supply 10
15 3Com Powerware Uninterruptible Power System Prestige Series User manual Power Supply 7