Falcon SUP1.0K-1C user manual

User manual for the device Falcon SUP1.0K-1C

Device: Falcon SUP1.0K-1C
Category: Power Supply
Manufacturer: Falcon
Size: 0.16 MB
Added : 4/14/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Falcon SUP1.0K-1C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Falcon SUP1.0K-1C.

For your convenience

If looking through the Falcon SUP1.0K-1C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Falcon SUP1.0K-1C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Falcon SUP1.0K-1C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Falcon SUP1.0K-1C User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Falcon SUP1.0K-1C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Falcon SUP1.0K-1C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
FALCON ELECTRIC, INC.
TM
SUP Series User’s Guide
700-1000VA
SUP700-1C, SUP1.0K-1C
FALCON® ELECTRIC, INC.
5106 Azusa Canyon Road
Irwindale, CA 91706
Tel. 626-962-7770
Fax. 626 962-7720
WWW.FALCONUPS.COM
OM48031-SUP, 01/09/04, Rev A.
800.842.6940

Summary of the content on the page No. 2

TABLE OF CONTENTS Important Safety Instructions (READ FIRST) . . 2 Chapter 1. SUP UPS Overview . . . . 3 Chapter 2. Installation . . . . . . 4 Inspecting the Equipment . . . . 4 UPS Setup . . . . . . . 4 Communications Interface . . . . 5 Chapter 3. Controls, Displays & Functions. . . 6 Front Panel Diagram & Description . . . 6 LCD Symbol Descriptions . . . . 6 LCD Metering Display Modes . . . . 9 Rear Panel Diagram & Description . . . 9 Chapter 4. Operation . . . . . . 11 Turning The UPS On an

Summary of the content on the page No. 3

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions which must be followed during the installation, operation and maintenance of this UPS and its batteries. Please read all instructions before operating this equipment and save this manual for future reference. CAUTION All of the models presented herein are designed for installation and use in a controlled environment free of contamination. CAUTION This UPS utilizes voltage that may be hazardous. Do

Summary of the content on the page No. 4

CHAPTER 1 CHAPTER 1 ® FALCON SMP Series - Overview ® The FALCON SUP Series UPS has the unique ability to operate from either 120Vac domestic or 230Vac international utility power, while providing 120Vac domestic output power. The SUP does not perform frequency conversion, however it is the ideal solution for the international traveller requring voltage conversion. The Line-interactive or Automatic Voltage Regulator (AVR) feature provides output voltage regulation, while the UPS is operating

Summary of the content on the page No. 5

CHAPTER 2 CHAPTER 2 Installation Inspecting the Equipment ® If any FALCON equipment has been damaged during shipment, keep the shipping cartons and packing materials for the carrier and file a claim for shipping damage. If you discover damage after acceptance, file a claim for concealed damage. To file a claim for shipping damage or concealed damage: 1) File with the carrier within 15 days of receipt of the equipment; 2) Send a copy ® of the damage claim within 15 days to the Falcon Service

Summary of the content on the page No. 6

Communications Interface The UPS provides both a contact closure and a true RS-232 computer interface. The definition and setup for RS-232 is as follows: Baud Rate : 2400 bps Data Length : 8 bits Stop Bit : 1 bit Parity : None Pin #6: RS-232 data Tx out Pin #7: Common for Pin #6 and Pin #9 Pin #9: RS-232 data Rx In The definition and setup for DB9 (optional) is as follows: Pin #2: AC Power Failure Pin #4: Common GND of Pin #2 & Pin #5 Pin #5: UPS Battery Low Pin #6: Turn off UPS Pin #7: GND fo

Summary of the content on the page No. 7

CHAPTER 3 CHAPTER 3 Controls, Displays & Functions FRONT PANEL B C A A. Main Control Button - This button is used to turn the UPS on and off, to perform a UPS self test, or to reset and silence an audible alarm. Refer to page 10 for operation instructions. B. A Liquid Crystal Display (LCD) is provided. Please reference the number designation for the display function and the function descriptions referenced in this manual. Refer to pages 6-8 in this

Summary of the content on the page No. 8

LCD SYMBOL DESCRIPTIONS LCD DISPLAY 1. Over Load --The connected load exceeds the UPS output rating. Remove some of the load from the UPS to correct this condition. 2. Load Level --Bar graph indicates the percent of UPS load capacity remaining. 3. UPS is loaded - This symbol is displayed when the UPS output load exceeds 30 watts and disappears when the load is under 25%. 4. Normal Mode - The sinewave symbol will be displayed when the UPS is operating normally from the utility line. Batt

Summary of the content on the page No. 9

6 Boost Mode - The AVR is increasing the UPS output voltage due to a low utility voltage condition or "Brown-out". The sinewave symbol is also displayed to indicate that the UPS is operating normally from the utility line. 7. Timer is enabled - This symbol will be displayed during the following conditions: a) The UPS has been programmed to automatically turn on or off using the supplied remote monitoring software. b) The green mode is enabled and the UPS output load is under 25 watts. The UPS

Summary of the content on the page No. 10

15. LCD Metering Display - When the UPS is turned on, this portion of the LCD display indicates the AC output voltage initially. Depressing the downward scroll button will indicate the following each time it is depressed: LCD Metering Display Modes (use display scroll buttons to change modes; modes are in descending order) Mode Value Display Description AC Output Voltage AC Output Voltage AC Input Voltage AC Input Voltage AC Output Frequency (Hz) AC Output Frequency Battery Voltage DC Bat

Summary of the content on the page No. 11

2. Input Fuse - Always replace with the same fuse type and rating. 3. Inlet - for connection of incoming power cord. 4. UPS output receptacles - The top NEMA type receptacles will be found on all domestic (120V) models. IEC type receptacles will be found on international (230V) models. 5. DB-9 RS-232 computer interface connector. 6. Surge protected, RJ11 type telephone jacks - To provide surge protection for your fax, modem or other telecommunications devices. Connect the incoming telephone

Summary of the content on the page No. 12

CHAPTER 4 CHAPTER 4 Operation 1. Turning The UPS On and Off Depending on how the UPS was turned off, it may automatically turn on when the input plug is plugged in. If it does not turn on automatically, depress the control button located on the front panel for four seconds until the UPS turns on. To turn the UPS off press and hold the control button for five seconds or until the UPS turns off. UPS batteries will still continue to recharge after the UPS has turned off. 2. UPS Self Test Depr

Summary of the content on the page No. 13

6. Battery Charging This UPS is shipped from the factory with its batteries fully charged. However, some charge may be lost due to the self discharge characteristics of the internal sealed lead-acid battery. Always allow the UPS to recharge for 24 hours prior to use. To recharge, simply connect the UPS line cord to a powered receptacle. The UPS does not have to be turned on for batteries to recharge. During normal use, the UPS will self recharge should the battery be depleted due to a los

Summary of the content on the page No. 14

CHAPTER 5 CHAPTER 5 Maintenance & Technical Support 1. Care & Maintenance ® Falcon SUP Series UPSs are designed to be maintenance free. They can be cleaned with a damp cloth or non-abrasive cleanser, providing the UPS is turned off and the input plug is disconnected from the utility source. On a regular basis, check the vents to make sure they are kept free from accumulation of dust, dirt or lint. 2. Battery Replacement Warning Momentarily depressing the UPS control button while the UPS is o

Summary of the content on the page No. 15

NECESSARY PRECAUTIONS The following precautions should be observed by a qualified technician when working with batteries: 1. Remove watches, rings, or other metal objects. 2. Use tools with insulated handles. 3. Wear rubber gloves and boots. 4. Do not lay tools or metal parts on top of batteries 4. Storing the UPS and Batteries Should you need to store the UPS for a long period, fully recharge the battery just prior to storage and recharge the battery every 6 months by plugging the UPS into a

Summary of the content on the page No. 16

6. Technical Support ® Your FALCON Electric SUP Series UPS is backed by one of the finest customer service teams assembled. Write, call, fax or email should you require technical assistance or service. FALCON ELECTRIC, INC. 5106 Azusa Canyon Road Irwindale, CA. 91706 Voice 626.962.7770 Fax 626.962.7720 Service 800.842.6940 Email: service@falconups.com WWW.FALCONUPS.COM Should service be desired, you must first obtain a Return Material Authorization number (RMA) and return shipping instructions

Summary of the content on the page No. 17

WARRANTY WARRANTY 1. TIME AND SCOPE OF WARRANTY: ® 1.1 FALCON hereby warrants parts shipped under this Agreement to be free from defective workmanship for a period of one year following date of shipment. Accidental damage, misuse or normal wear and tear shall not be construed as a defect. 1.2 The date of shipment as used herein will be the date on the Bill of Lading. If no Bill of Lading is issued, the date of shipment shall be shown on seller's shipping document. 1.3 No provision of this

Summary of the content on the page No. 18

SUP Series™ UPS 700VA & 1kVA Model Number SUP700-1C SUP1.0K-1C Nominal VA 700 1000 Electrical Input Nominal AC Voltage 120V or 230V 120V or 230V Current-Amps 7 (120V), 3.6 (230V) 10 (120V), 5.2 ( 230V) AC Voltage Window -21% to 25% Frequency 50/60 Hz (Auto – Tracking) Frequency Range 47 – 63Hz UPS is designed for use on 120V domestic or 230V international utility power with neutral, line and ground connections. Electrical Output Watts 490 650 Nominal AC Voltage 120V


Alternative user manuals
# User manual Category Download
1 Falcon RACKMOUNT SG SERIES UPS PLUS SG1KRM-2TU User manual Power Supply 8
2 Falcon RACKMOUNT SG SERIES UPS PLUS SG2KRM-1TU User manual Power Supply 2
3 Falcon RACKMOUNT SG SERIES UPS PLUS SG2KRM-2TU User manual Power Supply 0
4 Falcon RACKMOUNT SG SERIES UPS PLUS SG1KRM-1TU User manual Power Supply 3
5 Falcon OM48021-1 User manual Power Supply 0
6 Falcon ED4000-A User manual Power Supply 0
7 Falcon RACKMOUNT UPS PLUS FN3KRM-2TXI User manual Power Supply 0
8 Falcon RACKMOUNT UPS PLUS FN3KRM-2 User manual Power Supply 2
9 Falcon RACKMOUNT SG SERIES UPS PLUS SG3KRM-2TU User manual Power Supply 0
10 Falcon RACKMOUNT SG SERIES UPS PLUS SG3KRM-1TU User manual Power Supply 0
11 Falcon RACKMOUNT UPS PLUS FN4KRM-2 User manual Power Supply 0
12 Falcon RACKMOUNT UPS PLUS FN4KRM-2TX User manual Power Supply 0
13 Falcon RACKMOUNT UPS PLUS FN4KRM-2TXI User manual Power Supply 0
14 Falcon RACKMOUNT UPS PLUS FN6KRM-2 User manual Power Supply 1
15 Falcon RACKMOUNT UPS PLUS FN6KRM-2TXI User manual Power Supply 2
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2