ETA Systems PD11LVP user manual

User manual for the device ETA Systems PD11LVP

Device: ETA Systems PD11LVP
Category: Power Supply
Manufacturer: ETA Systems
Size: 0.34 MB
Added : 3/24/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ETA Systems PD11LVP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ETA Systems PD11LVP.

For your convenience

If looking through the ETA Systems PD11LVP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ETA Systems PD11LVP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ETA Systems PD11LVP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ETA Systems PD11LVP User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ETA Systems PD11LVP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ETA Systems PD11LVP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OWNER’S MANUAL
©
SYSTEMS
A Creative Light & Sound Company
1532 Enterprise Parkway • Twinsburg, Ohio 44087
330-425-3388 • 800-321-6699 • Fax: 330-425-9700
http://www.etasys.com E-mail eta@etasys.com

Summary of the content on the page No. 2

ETA’s line of Conditioned Power Distribution units are designed to reduce damage to sensitive electronic equipment from sudden voltage spikes, damaging power surges, and EMI/RFI noise, which is inherent in utility power lines. The PD11SP is a sequential four step/stage power up/down conditioned power distribution unit. It is designed to protect electronic equipment that requires a time-delayed start-up, particularly when high in-rush current can poten- tially damage audio, video, or computer equ

Summary of the content on the page No. 3

The PD11SS is a sequential four step/stage power up/down conditioned power distribution unit. It is designed to protect electronic equipment that requires a time-delayed start-up, particularly when high in-rush current can potentially damage audio, video, or computer equipment at power up. 1 thru 4 steps/stages in sequential power up/ 15 amp breaker down 1, 5, 10, 30 second pre-sets Breaker protected and unswitched 15 amp outlet Power switch Protection "On" Sequential On / Off Indicator On / O

Summary of the content on the page No. 4

Pull out lights Digital Voltmeter Protection "On" Power switch ON/OFF Breaker protected Readout Indicator On / Off HI/LOW and unswitched switch 15 amp outlet 20 amp Breaker 15 amp Breaker Pull out lights Front View PD11LVP Model Shown Back View PD11P, 11VP, 11LP, 11LVP Protected "Always On” 20 amp Outlets Back View PD11LVSP 3 pin terminal block for re sequential operation of un Protected "Always On” 20 amp Outlets Stage 1 Stage 2 Stage 3 Stage 4 Easy 4-step bulb replacement.

Summary of the content on the page No. 5

PD11P, PD11VP, PD11LP, PD11LVP Features: • Light Switch (PD11LP/LVP/LVSP) activates rack illumination; choice of HI or LOW intensity • Light Tubes (PD11LP/LVP/LVSP) illuminates up to 25 rack spaces • 4 dual 20 amp U-grounded switched outlets per unit • 1 dual 15 amp U-grounded "always on" and protected outlet • Digital Voltmeter Readout (PD11VP/LVP/LVSP) displays incoming line voltage • Resettable 20 amp thermal circuit breaker; 15 amp for front panel outlet • Lighted Outlet Power Switch activat

Summary of the content on the page No. 6

Audio Conditioned Power Distribution is also designed to Installation Requirements protect electronic equipment from potentially damaging high- PD11P, PD11VP, PD11LP, PD11SP, PD11LVP, PD11LVSP voltage spikes and surges. Plug unit into power source and observe status of four Sequencing Audio Conditioned Power Distribution is de- "Protection" light emitting diodes. The (green) “1st Stage”, signed to initiate a turn-on cycle, energizing one circuit “2nd Stage”, and “GROUND OK” L.E.D.’s should norma

Summary of the content on the page No. 7

Three-Wire Remote Control Interface A three-wire remote control interface is added to the main PC board for the PD11SS, PD11SP AND PD11LVSP units. This remote control interface is accessible through an external terminal block on the back of the unit (see Figure 6). This interface requires an external user provided switch, L.E.D., and a three-wire cable to implement. The interface has been tested reliably over 1000 feet with 22-gauge speaker wire (see Figures 1 and 5). Connect the short minus (-)

Summary of the content on the page No. 8

ETA Conditioned Power Distribution... The Benchmark By Which Professionals Compare. For over 20 years ETA has developed, manufactured Power Conditioning Firsts and sold high amperage theatrical lighting systems from from ETA which evolved an extensive line of rack mounted condi- tioned power distribution products designed to protect • “Always-On” Protected Outlets today’s sensitive electronic digital equipment. • 10 Rear Panel Outlets • Front Panel Convenience Outlets The “PD” Conditioned Power


Alternative user manuals
# User manual Category Download
1 ETA Systems EPD10VIEC-CE User manual Power Supply 0
2 ETA Systems EPD11LIEC-CE User manual Power Supply 0
3 ETA Systems EPDLOIEC-CE User manual Power Supply 0
4 ETA Systems ETA-C15D User manual Power Supply 4
5 ETA Systems EPD11LVIEC-CE User manual Power Supply 0
6 ETA Systems ETA-S15L User manual Power Supply 0
7 ETA Systems ETA-ECM20 User manual Power Supply 1
8 ETA Systems ETA-20SH User manual Power Supply 0
9 ETA Systems ETA-ECM20M User manual Power Supply 0
10 ETA Systems ETA-S15 User manual Power Supply 0
11 ETA Systems PD10VRS User manual Power Supply 14
12 ETA Systems PD11LVSP User manual Power Supply 0
13 ETA Systems PD11LP User manual Power Supply 19
14 ETA Systems PD11SSP User manual Power Supply 0
15 ETA Systems PD11SS User manual Power Supply 9
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2