Emerson NT5C06D user manual

User manual for the device Emerson NT5C06D

Device: Emerson NT5C06D
Category: Power Supply
Manufacturer: Emerson
Size: 0.61 MB
Added : 9/15/2014
Number of pages: 56
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson NT5C06D. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson NT5C06D.

For your convenience

If looking through the Emerson NT5C06D user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson NT5C06D on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson NT5C06D to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson NT5C06D User manual - Online PDF
Advertisement
« Page 1 of 56 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson NT5C06D but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson NT5C06D. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Astec Advanced Power Systems
UM5C06D ( 169-2071-504 )
Helios Rectifier 25/48 Single Phase -48V, 25 A
Power Factor Corrected Switch Mode Rectifier
NT5C06D
Installation and User Manual




P0831010 Standard 7.00 May 2001
Astec Advanced Power Systems
A part of Emerson Network Power

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Astec Advanced Power Systems Helios Rectifier 25/48 Single Phase -48V, 25A Power Factor Corrected Switch Mode Rectifier NT5C06D Installation and User Manual Manual Number : UM5C06D ( 169-2071-504 ) Manual Status : Standard Manual Issue : 7.00 Release Date : May 2001 P0831010 Copyright 2001 Astec Advanced Power Systems Ltd All Rights Reserved Published in Canada The information contained in this manual is the property of Astec Advanced Power Systems and is subjec

Summary of the content on the page No. 4

Summary of the content on the page No. 5

5 Publication history May 2001 Standard issue 7.00. Manual modified to reflect the Emerson identity. ( EC 102-26438 ) September 1999 Standard 6.0. Document modified to be in accordance with Astec standards. (ECN 102-17331) May 1999 Standard 5.0. Document modified to reflect Astec identity. Figure 11 modified. (ECN 102-14852) March 1997 Std. release 4.0. New Float Voltage and Current Limit Factory Setting. August 1996 Std. release 3.0. Removal of extended temperature rectifier mode

Summary of the content on the page No. 6

6 Publication history This page is left blank intentionally. UM5C06D ( 169-2071-504 ) P0831010 Standard 7.00 May 2001

Summary of the content on the page No. 7

7 Contents Introduction.............................................................................................................. 11 Description.................................................................................................... 11 Applications .................................................................................................. 12 Equipment Identification.................................................................................. 12 MPS75 NT5C10C(X)

Summary of the content on the page No. 8

8 Contents Forced Load Share ................................................................................................32 Load Share Adjustment Procedure ........................................................................32 Operation.................................................................................................................. 33 Front panel controls........................................................................................ 34 Features ..........

Summary of the content on the page No. 9

Contents 9 RFA fault..............................................................................................................47 SEN FAIL fault......................................................................................................48 Erratic load fault...................................................................................................48 Current or voltage float fault ................................................................................48 Appendi

Summary of the content on the page No. 10

10 Contents This page is left blank intentionally. UM5C06D ( 169-2071-504 ) P0831010 Standard 7.00 May 2001

Summary of the content on the page No. 11

11 1. Introduction Description The NT5C06D Switch Mode Rectifier is rated for 25 A at -48 V DC. This rectifier incorporates AC input power factor correction circuitry, is highly efficient and lightweight (15 lbs.). It is fully connectorized and plugs into a power shelf into which up to three rectifiers can be installed. The rectifier is forced air cooled with air entering from the front and exhausting out the rear of the power shelf. Separate or common AC power feeds are connected to th

Summary of the content on the page No. 12

12 Introduction Applications The rectifier is designed to function as the prime source of power for equipment requiring -48 V DC. It will also operate as a battery charger or as a battery replacement (batteryless operation). Its low output noise and good voltage regulation, combined with a 0.01% V coefficient for each degree C of temperature, provides an excellent charging facility to maintain a battery fully charged. The NT5C06D rectifier is designed to operate continuously in a small

Summary of the content on the page No. 13

Introduction 13 Helios Rectifier 25/48     NT5C06D(X) –48 V / 25 A Switch Mode Rectifier The NT5C06D provides -48 V / 25 A of isolated, filtered, and regulated DC power from a single phase AC source, for powering a load while charging a positive grounded battery. The output voltage can be adjusted from 46.0 to 56.0 V for floating a 23 or 24 cell battery string. The rectifier is designed for automatic precharge upon insertion into the MPS75 power shelf. When the NT5C06D is plugged in

Summary of the content on the page No. 14

14 Introduction Figure 2 - MPS75 Modular Power shelf- NT5C10C with 26-pin signal connectors Mounting Mounting holes (4) holes (4) Signal cable connection DC connection Figure 3 - NT5C06D Switch Mode Rectifier Height: 168 mm (6.60 inches) Depth: 260 mm (10.25 inches) Width: 149 mm (5.85 inches) Weight:6.8 kg (15 lbs) EQL FLT FAN HVSD ON RFA DC CC AC CA F1 OUTPUT 3MA 250V V+ LOA D V- CHARG E SO RTIE MPR25 MPR15 UM5C06D ( 169-2071-504 ) P0831010 Standard 7.00 May 2001

Summary of the content on the page No. 15

15 2. Specifications Electrical specifications The NT5C06D rectifier operates within the electrical specifications listed in Table 1. (Refer to the Product Specification which can be obtained from the Engineering department of Astec Advanced Power Systems). Table 1 - Electrical specifications Input Voltage Rating: Nominal 208 / 240 V AC single-phase, 47-63 Hz. Input Voltage Range 176 to 264 V AC. Starting range 184 to 260 V AC. When three-phase 208 / 240 V AC source is available to po

Summary of the content on the page No. 16

16 Specifications Table 1 - Electrical specifications ( continued ) A single pole 35 A circuit breaker is connected in series with the Output Protection: negative output lead of the rectifier. The rectifier contains an adjustable output current limit circuit for protection against damage from overloads. This circuit is factory set to limit the output current to 30 A. It can, however, be adjusted from 12.5 A to 30 A. At point of regulation: within ± 0.5% of the selected value for all

Summary of the content on the page No. 17

Specifications 17 Environmental specifications Operating CAUTION An airflow clearance must be left at the rear of the shelf. A minimum of three inches is recommended. The rectifier will operate satisfactorily under the following environmental conditions: Temperature Range: 0° to +65° C (32° to 149° F) NT5C06DA/DB equipped without an air filter 0° to +50° C (32° to 122° F) equipped with an air filter Humidity: 0 to 95% RH (non-condensing) Altitude: Sea level to 21

Summary of the content on the page No. 18

18 Specifications The rectifier contains aluminum electrolytic capacitors having a shelf life of 5 years or greater when stored at the maximum rated storage temperature. UM5C06D ( 169-2071-504 ) P0831010 Standard 7.00 May 2001

Summary of the content on the page No. 19

19 3. Installation and start up The power shelf must be installed on the framework and all AC, DC and control and alarm wiring must be connected before the rectifiers are physically plugged in. Tools and test equipment The following tools and test equipment are required: • Screwdriver, flat blade (3/8-inch) • Screwdriver, flat blade (3/32-inch) • Screwdriver, Burns No. 60, or equivalent • Cable strippers / electrician’s knife • Wire stripper • Cable cutters (2/0) • Linesman’s pliers

Summary of the content on the page No. 20

20 Installation and start-up Procedure 1 - Installing the power shelf Step Action 1 Position the power shelf, without any rectifiers plugged in, against the framework. 2 Secure the shelf in the position indicated by the job drawing (normally directly below the controller or another shelf). At least one star washer must be installed on one holding screw to ensure maximum framework ground continuity. 3 Release the clamping bar from the front of the power shelf 4 Remove the AC and DC ju


Alternative user manuals
# User manual Category Download
1 Emerson 1000 User manual Power Supply 64
2 Emerson 1500VA User manual Power Supply 15
3 Emerson 2200 User manual Power Supply 4
4 Emerson 3000 User manual Power Supply 41
5 Emerson 250-400kVA User manual Power Supply 16
6 Emerson 1000VA User manual Power Supply 3
7 Emerson 40-120KVA User manual Power Supply 2
8 Emerson 500VA User manual Power Supply 3
9 Emerson 4-16kVA User manual Power Supply 2
10 Emerson 60HZ User manual Power Supply 0
11 Emerson 650VA User manual Power Supply 1
12 Emerson 12-20kVA User manual Power Supply 11
13 Emerson 480VAC User manual Power Supply 1
14 Emerson 6 kVA User manual Power Supply 18
15 Emerson Albr BDS-256XL User manual Power Supply 0
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2