Emerson THROUGH 1200 user manual

User manual for the device Emerson THROUGH 1200

Device: Emerson THROUGH 1200
Category: Power Supply
Manufacturer: Emerson
Size: 0.57 MB
Added : 9/15/2014
Number of pages: 11
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson THROUGH 1200. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson THROUGH 1200.

For your convenience

If looking through the Emerson THROUGH 1200 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson THROUGH 1200 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson THROUGH 1200 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson THROUGH 1200 User manual - Online PDF
Advertisement
« Page 1 of 11 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson THROUGH 1200 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson THROUGH 1200. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

7000 Series ACTS
Operator’s
Automatic Closed–Transition Transfer Switches
Manual
H–design 600 through 1200 amps
TABLE OF CONTENTS
DANGER is used in this manual to warn of high
section-page
voltages capable of causing shock, burns, or death.
INSTALLATION ........................ 1-1
!
Mounting and Line Connections ......... 1-1
Auxiliary Circuits and Harness........... 1-2
WARNINGisusedinthismanualtowarn
Engine Starting Contacts ............... 1-2 of possible personal injury.
FunctionalTest ....

Summary of the content on the page No. 2

Rating Label Nameplate The Transfer Switch nameplate includes data for each Each Automatic Closed–Transition Transfer Switch contains specific7000SeriesACTS. Use the switchonly withinthe a rating label to define the loads and fault circuit withstand/ limitsshownonthisnameplate.AtypicalCatalogNumber closing ratings. Refer to the labelon the Transfer Switch for isshownonthe next page withitselementsexplained. specificvalues. ! Catalog NumberIdentification Do notexceed the values on the rating labe

Summary of the content on the page No. 3

field connections ground lug terminalblock TB Transfer Control &lights power connections Group 5 Controller Transfer Switch power connections 1200amp sizeintypicalenclosurewithlocationof customer connections

Summary of the content on the page No. 4

SECTION1 INSTALLATION ASCO 7000 Series Automatic Closed–Transition Trans- Testing PowerConductors ferSwitches(ACTSs)arefactorywiredandtested.Field Do not connect the power conductors to the transfer installationrequiresmountingandconnectionofservice switch until they are tested. Installing power cables in cables, andauxiliary controlcircuits(if required). conduit, cable troughs and ceiling-suspended hangers often requires considerable force. The pulling of cables candamage insulationandstretch o

Summary of the content on the page No. 5

INSTALLATION (continued) Engine Starting Contacts All customer connections, including the engine control contact connections, are located on terminal block TB whichismountedonthe topright sideof theenclosure. Refertothewiringdiagramprovidedwiththeautomatic transferswitchandconnect theengine startwirestothe appropriate terminals. See Figure 1–1andTable A. Table A. Engine start connections. When normal source Terminals on fails Terminal Block TB contact closes TB1 and TB2 contact opens TB1 and TB3

Summary of the content on the page No. 6

INSTALLATION (continued) 1–Manual OperationTest Adetachablemaintenancehandleisprovidedontheframe of the Transfer Switch for maintenance purposes only. Manual operation of the transfer switch should be checkedbefore it isenergized(operatedelectrically). left side of ! transfer switch Do notmanually operate the transfer switch until bothpower sources are disconnected: open bothcircuitbreakers. 1. After deenergizing both power sources, open the enclosuredoor.Locateandremovethemaintenance Emergencys

Summary of the content on the page No. 7

INSTALLATION (continued) Automatic Closed Transition Transfer Switch Transfer Transfer Switch Control Transfer Switch Connected Connected Transfer Extended Failure TS Retransfer Test To To Parallel To Locked Delay HOLD FOR Normal Emergency Bypass ( Time Synchronize Out 15 SECONDS) GREEN RED RED RED RED observe Normal Emergency Closed Source Source Alarm Transition these lights Accepted Accepted Bypass Reset GREEN RED Figure 1-6. Standard controls and indicators. Close the normalsource circuit br

Summary of the content on the page No. 8

INSTALLATION (continued) Automatic Closed Transition Transfer Switch Transfer Transfer Switch Control Transfer Switch Connected Connected Transfer Extended Failure TS Retransfer Test To To Parallel To Locked Delay HOLD FOR Normal Emergency Bypass ( Time Synchronize Out 15 SECONDS) GREEN RED RED RED RED operate observe Normal Emergency Closed Source Source Alarm Transition these lights this switch Accepted Accepted Bypass Reset GREEN RED Figure 1-7. Standard controls and indicators. 3 --- Electri

Summary of the content on the page No. 9

SECTION2 TESTING&SERVICE TRANSFER TEST DISCONNECTING THE CONTROLLER Operate the7000SeriesACTSatleast oncea monthby The harness disconnect plugs are furnished for repair following the five–step Electrical Operation Transfer purposes only and should not have to be unplugged. If Testprocedure onpage 1–5. the controller must be isolated, followthese steps: Disconnecting the Plugs PREVENTIVE MAINTENANCE ! Reasonable care in preventive maintenance will insure high reliability and long life for the 700

Summary of the content on the page No. 10

TESTING&SERVICE (continued) 2. Use the maintenance handle to manually operate the MANUAL LOADTRANSFER transfer switch to the opposite source. First open the This procedure will manually transfer the load if the closed contacts, then close the other contacts. Do not controller is disconnected. leavebothclosed.SeeManual Operationon page1–3. ! 3. Thenremovethemaintenancehandle. Seepage1–3. Do notmanually operate the transfer switch ! until bothpower sources are disconnected (all conductors deenergi

Summary of the content on the page No. 11

INDEX A I S alarmreset, 1–5, 2–2 inspection, 2–1 settings see ControllerUser’s Guide auxiliarycircuits, 1–2 installation, 1–1 indicators, contact position, 1–3 T C L test, functional, 1–2, 1–3, 1–4, 1–5 cable labels, lugs, 1–2 time delays, 2–1 engine start contacts, 1–2 preparation, 1–2 see ControllerUser’s Guide rating, cover catalognumber, inside cover TransferControlselectorswitch lights, 1–4, 1–5 RetransferDelay Bypass, 1–5 cleaning, 2–1 TransferTest, 1–5 lubrication, 2–1 closedtransitionbyp


Alternative user manuals
# User manual Category Download
1 Emerson 1000 User manual Power Supply 64
2 Emerson 1500VA User manual Power Supply 15
3 Emerson 2200 User manual Power Supply 4
4 Emerson 3000 User manual Power Supply 41
5 Emerson 250-400kVA User manual Power Supply 16
6 Emerson 1000VA User manual Power Supply 3
7 Emerson 40-120KVA User manual Power Supply 2
8 Emerson 500VA User manual Power Supply 3
9 Emerson 4-16kVA User manual Power Supply 2
10 Emerson 60HZ User manual Power Supply 0
11 Emerson 650VA User manual Power Supply 1
12 Emerson 12-20kVA User manual Power Supply 11
13 Emerson 480VAC User manual Power Supply 1
14 Emerson 6 kVA User manual Power Supply 18
15 Emerson Albr BDS-256XL User manual Power Supply 0
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2