Summary of the content on the page No. 1
RTM-ATCA-7350
Installation and Use
6806800H30F
February 2010
Summary of the content on the page No. 2
© 2010 Emerson All rights reserved. Trademarks Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service © marks of Emerson Electric Co. 2010 Emerson Electric Co. All other trademarks are the property of their respective owners. ® Intel is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. ™ Java and all other Java-based marks are trademarks or registered
Summary of the content on the page No. 3
Contents About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 1.1 Overview of RTM-ATCA-7350 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 1.2 Mechanical Data . . . . . . . . . . . . . .
Summary of the content on the page No. 4
Contents 2.8.3 Connecting Optical Fibers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 3 Controls, LEDs and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 3.2 Face Plate Connectors and LEDs . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 5
List of Tables Table 1-1 Mechanical Specifications of RTM-ATCA-7350 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Table 1-2 Standard Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 1-3 Product Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 1-4 Available Board Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 6
List of Tables 6 RTM-ATCA-7350 Installation and Use (6806800H30F)
Summary of the content on the page No. 7
List of Figures Figure 2-1 Wearing the ESD-Preventive Wrist Strap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 2-2 Removing the Filler Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Figure 2-3 Structure of RTM-ATCA-7350 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Figure 2-4 Installing the GE Daughter Card . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 8
List of Figures 8 RTM-ATCA-7350 Installation and Use (6806800H30F)
Summary of the content on the page No. 9
About this Manual Overview of Contents This manual is intended for the users who install and configure the RTM-ATCA-7350 of the server blade. The user must be a professional engineer in the server device field, who has been trained and is able to identify danger levels when operating the device. This manual describes the structure, appearance, functions, technical specifications, precautions, and installation procedure of the RTM-ATCA-7350. In addition, it also provides information of the
Summary of the content on the page No. 10
About this Manual Abbreviation Definition FCC Federal Communications Commission FRU Field Replaceable Unit GE Gigabit Ethernet IEC International Electrotechnical Commission IPMB Intelligent Platform Management BUS IPMC Intelligent Platform Management Controller IPMI Intelligent Platform Management Interface KVM Keyboard, Video, and Mouse OOS Out of Service PCI Peripheral Component Interconnect RTM Rear Transition Module SCSI Small Computer System Window SDR Sensor Data Record SEL System Event
Summary of the content on the page No. 11
About this Manual Notation Description ... Repeated item for example node 1, node 2, ..., node 12 . Omission of information from example/command that is not necessary at . the time being . .. Ranges, for example: 0..4 means one of the integers 0,1,2,3, and 4 (used in registers) | Logical OR Indicates a hazardous situation which, if not avoided, could result in death or serious injury Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury Indicat
Summary of the content on the page No. 12
About this Manual Comments and Suggestions We welcome and appreciate your comments on our documentation. We want to know what you think about our manuals and how we can make them better. Mail comments to us by filling out the following online form: http://www.emersonnetworkpowerembeddedcomputing.com/ > Contact Us > Online Form In "Area of Interest" select "Technical Documentation". Be sure to include the title, part number, and revision of the manual and tell us how you used it. 12 RTM
Summary of the content on the page No. 13
Introduction 1 1.1 Overview of RTM-ATCA-7350 The ATCA-7350 Rear Transition Module (RTM) of the server blade (hereinafter referred to as RTM-ATCA-7350) must work with the server blade ATCA-7350. RTM-ATCA-7350 provides external interfaces for the connected server blade. RTM-ATCA-7350 provides the following functions: RTM-ATCA-7350 provides two daughter card connectors. RTM-ATCA-7350 supports the following daughter cards: – Gigabit Ethernet (GE) daughter card – Fiber Channel (FC) daughter ca
Summary of the content on the page No. 14
Introduction Standard Compliances 1.3 Standard Compliances The product is designed to meet the following standards. Table 1-2 Standard Compliances Standard Description Legal safety requirements UL 60950-1 EN 60950-1 IEC 60950-1 CAN/CSA C22.2 No 60950-1 CISPR 22 EMC requirements (legal) on system level (predefined Emerson Network Power Embedded Computing system) CISPR 24 EN 55022 EN 55024 FCC Part 15 Industry Canada ICES-003 VCCI Japan AS/NZS CISPR 22 EN 300 386 NEBS Standard GR-1089 CORE NE
Summary of the content on the page No. 15
Board Accessories Introduction Table 1-3 Product Nomenclature (continued) Order Number Description RTM-ATCA-7350-2GE RTM FOR THE ATCA-7350 BLADE WITH 4 GE INTERFACES (ROHS 5/6) RTM-ATCA-7350-FC RTM FOR THE ATCA-7350 BLADE WITH 2 FC INTERFACES (ROHS 5/6) 1.4.2 Board Accessories As of the printing date of this manual, the following board accessories were available. Table 1-4 Available Board Accessories Board Accessories Order Number Gigabit Ethernet (GE) daughter card MEZC-RTM-7150-GE 1 Fibe
Summary of the content on the page No. 16
Introduction Board Accessories 16 RTM-ATCA-7350 Installation and Use (6806800H30F)
Summary of the content on the page No. 17
Hardware Preparation and Installation 2 2.1 Overview This chapter describes: Unpacking and inspecting RTM-ATCA-7350 Precautions during the operation Preparations before installation Installation procedure Installing and replacing daughter cards Connection of external cables Removal procedure 2.2 Unpacking and Inspecting RTM-ATCA-7350 Damage of Circuits Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life. Before touchi
Summary of the content on the page No. 18
Hardware Preparation and Installation Environmental and Power Requirements 3. Remove the desiccant bag shipped together with the blade and dispose of it according to your country’s legislation. The product is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, please contact our customer's service immediately. 2.3 Environmental and Power Requirements The following environmental and power requirements are applicable to the board. 2.3.
Summary of the content on the page No. 19
Power Requirements Hardware Preparation and Installation Table 2-1 Environmental Requirements (continued) Requirement Operating Non-Operating Free Fall 1,200 mm (Packaged) /all edges and corners 1.0m (Packaged) per ETSI 300 019-2-2 (Blade level packaging) 25mm (unpackaged) per GR-63-CORE 2.3.2 Power Requirements Table 2-2 Power Requirements Requirement Operating Power supply Provided by the server blade Maximum power consumption 14.2 W 2.4 Module Installation and Removal Personal Injury
Summary of the content on the page No. 20
Hardware Preparation and Installation Ejector Handles Module Damage If the blade is not fully aligned with the interface in the backplane, too much force may twist the pins on the blade or backplane. Do not exert too much force when you insert the blade. Note the following points at the time of installing RTM-ATCA-7350: Make sure that you wear an electrostatic discharge (ESD)-preventive wrist strap to prevent the static electricity from hurting you or damaging the device. Keep your perso