Emerson NX user manual

User manual for the device Emerson NX

Device: Emerson NX
Category: Power Supply
Manufacturer: Emerson
Size: 2.95 MB
Added : 9/15/2014
Number of pages: 48
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson NX. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson NX.

For your convenience

If looking through the Emerson NX user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson NX on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson NX to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson NX User manual - Online PDF
Advertisement
« Page 1 of 48 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson NX but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson NX. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AC Power
For Business-Critical Continuity™
® ™
Liebert NX
Operation and Maintenance Manual – 225-600kVA, Three-Phase, Single-Module & Multi-Module

Summary of the content on the page No. 2

CONTACTING EMERSON NETWORK POWER FOR SUPPORT To contact Emerson Network Power Liebert Services for information or repair service in the United States, call 800-543-2378. Liebert Services offers a complete range of star-up services, repair services, preventive maintenance plans and service contracts. For repair or maintenance service outside the 48 contiguous United States, contact Liebert Services, if available in your area. For areas not covered by Liebert Services, the authorized distributo

Summary of the content on the page No. 3

TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

2.6 Automatic Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 2.6.1 Overloads (Without Transfer) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 2.6.2 Automatic Transfers to Bypass (Overload Condition) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 2.6.3 Automatic Transfers to Bypass, UPS System Faults. . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 5

FIGURES Figure 1 Typical single module UPS system one-line diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 2 Main component locations-225 to 300kVA Liebert NX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Figure 3 Main components, 400-600kVA Liebert NX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Figure 4 Main display screen, typical. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 6

iv

Summary of the content on the page No. 7

Important Safety Instructions IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation of your Liebert NX UPS. Read this manual thoroughly, paying special attention to the sections that apply to your installation, before working with the UPS. Retain this manual for use by installing personnel. WARNING ! Risk of electric shock. Can cause equipment damage, injury or death. This UPS has several circuits that are

Summary of the content on the page No. 8

Important Safety Instructions Battery Cabinet Precautions The following warning applies to all battery cabinets supplied with UPS systems. Additional warnings and cautions applicable to battery cabinets may be found in Important Safety Instructions on page 1 and 4.4 - Battery Maintenance. WARNING ! Risk of electric shock, fire and smoke. Can cause equipment damage, injury and death. Internal battery strapping must be verified by manufacturer prior to moving a battery cabinet after initial ins

Summary of the content on the page No. 9

Introduction 1.0 INTRODUCTION 1.1 General Description The Liebert NX UPS provides continuous, high-quality AC power to your business-critical equipment, such as telecommunications and data processing equipment. The Liebert NX UPS supplies power that is free of the disturbances and variations in voltage and frequency common to utility power, which is subject to brownouts, blackouts, surges and sags. The Liebert NX utilizes the latest in high-frequency, double-conversion pulse-width modulation

Summary of the content on the page No. 10

Introduction 1.2 Modes of Operation 1.2.1 Normal Mode Operating in normal mode, the Liebert NX’s rectifier derives power from a utility AC source and supplies regulated DC power to the inverter, which regenerates precise AC power to supply the connected equipment. The rectifier also uses the utility source power to charge the DC sources. 1.2.2 Bypass Mode When the Liebert NX is in bypass mode, the load is directly supported by utility power and is without DC source backup protection. ’ The Li

Summary of the content on the page No. 11

Introduction 1.3 Options ® A number of options are available from Emerson for your UPS system. Some options are not available for all ratings. Described below are the most frequently provided options. Other options are available. Contact your Emerson sales representative for more information. • Battery and Racks—The batteries provide power in the event of a power outage. The Liebert NX UPS can use a variety of battery types, provided the battery plant is designed for the UPS DC voltage range

Summary of the content on the page No. 12

Operation 2.0 OPERATION The Liebert NX UPS is equipped with a microprocessor-based display touchscreen designed for convenient and reliable operation. The display is driven by menu-prompted software. 2.1 Features The Liebert NX interface display enables the operator to perform such tasks as: • Quickly check operational status • Monitor the power flow through the UPS system and all meter readings • Execute operational procedures • Check status reports and event files • Adjustment programmable pa

Summary of the content on the page No. 13

Operation Figure 3 Main components, 400-600kVA Liebert NX HMI Screen Main Input Circuit Breaker (CB1) Optional Backfeed Circuit Breaker (BFB) External Communication Panel FRONT DOORS REMOVED Bypass Busbars Ø A,B,C Rectifier Input Busbars Ø A,B,C Output Busbars Ø A,B,C Battery Busbars (+ / -) Input Ground Busbar DOORS AND INNER SKINS REMOVED ® ™ 7Liebert NX

Summary of the content on the page No. 14

Operation Figure 4 Main display screen, typical 9 1 3 5 2 8 6 4 7 1. Bypass Input: voltage and frequency readings 4. Battery: voltage and current readings 2. Line power Input: voltage, current and fre- 5. System Status quency readings 6. Control Buttons 3. Output: voltage, current and frequency read- 7. Menu Buttons ings 8. Animated One Line Mimic 9. About Button Figure 5 Normal Mode Module Bypass UPS Module AC Input BFB Module Rectifier UPS Output AC Input DC Critical Bus Load To DC Supply Fig

Summary of the content on the page No. 15

Operation Figure 7 Load on bypass Module Bypass UPS Module AC Input BFB Module Rectifier UPS Output DC Critical AC Input Bus Load To DC Supply 2.2 Touchscreen Navigation Several menu items can be accessed from the main display screen (see Figure 9). These menu items are detailed in subsequent sections. 2.2.1 Main Display Screen This is the default screen. It displays the following information: • Bypass Input Voltage • Bypass Input Frequency •Input Voltage • Input Current • Input Frequency • Ou

Summary of the content on the page No. 16

Operation 2.2.2 Status This menu item displays a list of current Fault Warnings and Info. Figure 8 Status 2.2.3 Events Log Menu This menu item displays the list of Events that occurred recently while the UPS was in operation. 2.2.4 Measures Menu This menu item displays the full set of measurements for each functional block (rectifier, bypass, booster/charger, batteries, inverter and load). Table 1 Measurements for functional blocks Rectifier Bypass Inverter Chg/Boost Battery Load Booster Voltag

Summary of the content on the page No. 17

Operation Figure 9 Measures menus 2.2.5 Battery Menu This menu item displays the battery status/parameters such as temperature, cell voltage, capacity and run time, as well as commands that enable the user to the user to configure and execute the battery test. Battery Status • Battery Status— Specify whether battery is charging or not • Charger Status—Specify Battery Charger status • Battery Test Status—Specify details of the last battery test ex

Summary of the content on the page No. 18

Operation Battery Measures This section monitors variables applicable to the battery. Figure 10 Battery parameters ® ™ Liebert NX 12

Summary of the content on the page No. 19

Operation 2.2.6 Life Menu This menu displays the information about the status of Liebert LIFE.net connections, status of calls and types of calls and allows certain specific commands to be executed. This button is not active if the LIFE.net option is not available on UPS. Figure 11 Life menu ® ™ 13 Liebert NX

Summary of the content on the page No. 20

Operation 2.2.7 Settings Menu This menu item displays the LCD settings and selected language. Figure 12 Settings Menu 2.3 Animated One Line Mimic This displays all the functional blocks in the UPS. Touch any icon to obtain detailed information about the corresponding functional block. The color of the block identifies its functional status: • Green: Normal Conditions • Yellow: Warning Conditions • Red: Fault Conditions By clicking on a block, such as Rectifier or Inverter, the relevant page pro


Alternative user manuals
# User manual Category Download
1 Emerson 1000 User manual Power Supply 64
2 Emerson 1500VA User manual Power Supply 15
3 Emerson 2200 User manual Power Supply 4
4 Emerson 3000 User manual Power Supply 41
5 Emerson 250-400kVA User manual Power Supply 16
6 Emerson 1000VA User manual Power Supply 3
7 Emerson 40-120KVA User manual Power Supply 2
8 Emerson 500VA User manual Power Supply 3
9 Emerson 4-16kVA User manual Power Supply 2
10 Emerson 60HZ User manual Power Supply 0
11 Emerson 650VA User manual Power Supply 1
12 Emerson 12-20kVA User manual Power Supply 11
13 Emerson 480VAC User manual Power Supply 1
14 Emerson 6 kVA User manual Power Supply 18
15 Emerson Albr BDS-256XL User manual Power Supply 0
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2