Emerson GXT3 user manual

User manual for the device Emerson GXT3

Device: Emerson GXT3
Category: Power Supply
Manufacturer: Emerson
Size: 3.2 MB
Added : 9/15/2014
Number of pages: 48
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson GXT3. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson GXT3.

For your convenience

If looking through the Emerson GXT3 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson GXT3 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson GXT3 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson GXT3 User manual - Online PDF
Advertisement
« Page 1 of 48 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson GXT3 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson GXT3. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AC Power
For Business-Critical Continuity™
® ™
Liebert GXT3 UPS 120V/208V 500VA-3000VA
User Manual

Summary of the content on the page No. 2

Summary of the content on the page No. 3

TABLE OF CONTENTS IMPORTANT SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 GLOSSARY OF SYMBOLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.0 PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

4.0 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 4.1 Startup Checklist for the Liebert GXT3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4.2 Starting the UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4.3 Manual Battery Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 5

FIGURES Figure 1 Liebert GXT3 rack/tower models—front view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 2 Liebert GXT3 minitower—front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 ® ™ Figure 3 Liebert GXT3 120V rack/tower models—rear panel components . . . . . . . . . . . . . . . . . . . . . . . . 6 ® ™ Figure 4 Liebert GXT3 208V rack/tower models—rear panel components . . . . . . . . . . . .

Summary of the content on the page No. 6

iv

Summary of the content on the page No. 7

IMPORTANT SAFETY PRECAUTIONS WARNING ! Observe all cautions and warnings in this manual. Failure to do so may result in serious injury or death. Refer all UPS and battery service to properly trained and qualified service personnel. Do not attempt to service this product yourself. Opening or removing the cover may expose you to lethal voltages within this unit even when it is apparently not operating and the input wiring is disconnected from the electrical source. Never work alone. SAVE THESE

Summary of the content on the page No. 8

® ™ The Liebert GXT3 -3000RT208 was tested under 20A branch circuit in accordance with the National Electrical Code, ANSI/NFPA 70. To reduce the risk of fire, connect only to a circuit provided with 20A maximum branch overcurrent protection. Battery Safety CAUTION ! Do not dispose of batteries in a fire. The batteries may explode. Do not open or mutilate the batteries. Released electrolyte is toxic and is harmful to skin and eyes. Dispose of used batteries according to the instructions. CAUT

Summary of the content on the page No. 9

GLOSSARY OF SYMBOLS Risk of electrical shock Indicates caution followed by important instructions ! AC input AC output Requests the user to consult the manual i - + Indicates the unit contains a valve-regulated lead acid battery PbH2SO4 R Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage ON/Alarm Silence/Battery Test OFF/Bypass WEEE 3

Summary of the content on the page No. 10

Product Description 1.0 PRODUCT DESCRIPTION ® ™ The Liebert GXT3 is a compact, online uninterruptible power system (UPS) that continuously conditions and regulates its output voltage. The Liebert GXT3 is designed to supply microcomputers and other sensitive equipment with clean sine wave input power. Upon generation, AC power is clean and stable. However, during transmission and distribution it is subject to voltage sags, spikes and complete failure that may interrupt computer operations, cau

Summary of the content on the page No. 11

Product Description 1.3 Appearance and Components 1.3.1 Front Panel and Controls ® ™ The Liebert GXT3 rack/tower and minitower models in various power ratings have the same general appearance, controls and features (see Figure 1). The various rack/tower and minitower models differ largely in the type of receptacles each has. Figure 1 Liebert GXT3 rack/tower models—front view Ventilation Slots Operation and Display Panel ™ The Liebert GXT3-1000MT120 has the same controls and features in a mini

Summary of the content on the page No. 12

Product Description ® ™ Figure 3 Liebert GXT3 120V rack/tower models—rear panel components 500VA, 700VA, 1000VA, 1500VA Models Input Power Plug and Cable 5-15P Input Circuit USB Port Breaker Liebert IntelliSlot Port Output Receptacles, 5-15R External Terminal Block Battery Communication Connector Cooling Fan 2000VA Model Input Power Plug and Cable, 5-20P Input Circuit USB Port Breaker Liebert IntelliSlot Port Output Receptacles, 5-15/20R External Terminal Block Battery Communicatio

Summary of the content on the page No. 13

Product Description ® ™ Figure 4 Liebert GXT3 208V rack/tower models—rear panel components 3000VA Model Input Power Plug and Cable, L6-20P Output Output Circuit Input Circuit Receptacle, Breakers USB Port Breaker L6-20R Liebert IntelliSlot Port External Terminal Block Battery Cooling Communication Connector Fan Output Receptacles, L6-15R ™ Figure 5 Liebert GXT3-1000MT120 —rear panel components Input Power Plug and Cable, 5-15P 1000VA Model Terminal Block Input Circuit Communication Bre

Summary of the content on the page No. 14

Product Description 1.4 Major Components The operating principle of the UPS is illustrated in Figure 6. Figure 6 Operating principle diagram Input Output Dynamic Bypass TVSS & EMI/ Rectifier/ L1 Inverter L1 RFI Filters PFC DC-to-DC Converter Battery Battery Charger L2/N L2/N G G The UPS is composed of utility input, TVSS and EMI/RFI filters, rectifier/PFC, inverter, battery charger, DC-to-DC converter, battery, dynamic bypass and UPS output. Transient Voltage Surge Suppression (TVSS) and EMI

Summary of the content on the page No. 15

Product Description Battery Charger The battery charger utilizes energy from the utility power and precisely regulates it to continuously ® ™ float charge the batteries. The batteries are being charged whenever the Liebert GXT3 is plugged in, even when the UPS is not turned On. DC-to-DC Converter The DC-to-DC converter raises the DC voltage from the battery to the optimum operating voltage for the inverter. This allows the inverter to operate continuously at its optimum efficiency and voltage

Summary of the content on the page No. 16

Product Description 1.5.3 Battery Mode ® ™ The Liebert GXT3 enters Battery Mode when utility power fails or is outside acceptable values. The battery system supplies power through the DC-to-DC converter to the inverter to generate clean AC power for the connected loads. When the Liebert GXT3 enters Battery Mode, the UPS sounds a half-second beep at 10-second intervals. When approximately 2 minutes of run time remains, the beeps sound every 5 seconds to warn that the battery is getting low (t

Summary of the content on the page No. 17

Installation 2.0 INSTALLATION 2.1 Unpacking and Inspection Unpack the UPS and conduct the following checks: • Inspect the UPS for shipping damage. If any shipping damage is found, report it to the carrier and your local dealer or your Emerson representative immediately. • Check the accessories included in packaging list. If there is any discrepancy, contact your local dealer or your Emerson representative immediately. 2.2 What’s Included With GXT3 UPS • Compact Disk with: ® • Liebert MultiLin

Summary of the content on the page No. 18

Installation 2.4 Mechanical Installation ® ™ The Liebert GXT3 may be installed as a tower or in a rack, depending on space and use considerations. The Liebert GXT3 may be used alone, as a single UPS, or with up to four battery cabinets. NOTE When installing the UPS or making input and output connections, comply with all relevant safety codes and standards 2.4.1 Tower Installation To install the Liebert GXT3 as a tower: 1. Take out support bases from the accessories (see Figure 7). Figure 7 Su

Summary of the content on the page No. 19

Installation Figure 9 Rotate the operation and display panel Operation and Display Panel Rotated Clockwise 90 Degrees c. Pull the logo on the front plastic bezel cover gently, rotate it 90 degrees clockwise and snap it back into position. The rotated front plastic bezel cover is shown in Figure 10. ® ™ d. Replace the front plastic bezel cover on the Liebert GXT3 . At this point, the UPS operation and display panel and logo have been rotated 90 degrees clockwise, which provides upright viewin

Summary of the content on the page No. 20

Installation 2.4.2 Rack Installation NOTE ® ™ • When the Liebert GXT3 is installed in a rack, it must be supported by a shelf, fixed rails or slide rails on each side. The factory-supplied rack mount handles cannot sup- port the weight of the UPS. They are used to move the UPS into and out of the rack and attach the UPS to the rack. • Mounting hardware and slide rails are sold separately. Contact your local Emerson representative for these options and any assistance. • GXT3-1000MT120 cannot b


Alternative user manuals
# User manual Category Download
1 Emerson GXT3 User manual Network Card 71
2 Emerson 1000 User manual Power Supply 64
3 Emerson 1500VA User manual Power Supply 15
4 Emerson 2200 User manual Power Supply 4
5 Emerson 3000 User manual Power Supply 41
6 Emerson 250-400kVA User manual Power Supply 16
7 Emerson 1000VA User manual Power Supply 3
8 Emerson 40-120KVA User manual Power Supply 2
9 Emerson 500VA User manual Power Supply 3
10 Emerson 4-16kVA User manual Power Supply 2
11 Emerson 60HZ User manual Power Supply 0
12 Emerson 650VA User manual Power Supply 1
13 Emerson 12-20kVA User manual Power Supply 11
14 Emerson 480VAC User manual Power Supply 1
15 Emerson 6 kVA User manual Power Supply 18
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2