Eaton Electrical IT-RSS user manual

User manual for the device Eaton Electrical IT-RSS

Device: Eaton Electrical IT-RSS
Category: Power Supply
Manufacturer: Eaton Electrical
Size: 0.18 MB
Added : 5/30/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Eaton Electrical IT-RSS. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Eaton Electrical IT-RSS.

For your convenience

If looking through the Eaton Electrical IT-RSS user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Eaton Electrical IT-RSS on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Eaton Electrical IT-RSS to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Eaton Electrical IT-RSS User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Eaton Electrical IT-RSS but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Eaton Electrical IT-RSS. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




®
Innovative Technology TVSS Products
Instruction Manual:

IM01005012E
XT-40 & IT-RSS
Rev. 1 – February 2007
Installation


Contents
Page
1 Introduction ............................................................................. 1
1.1 Scope......................................................................... 1
1.2 XT-40 Catalog Numbering System............................ 1
1.3 IT-RSS System Wiring and Maximum Voltages........ 1
1.4 Safety Precautions.................

Summary of the content on the page No. 2

IM01005012E XT-40 & IT-RSS Installation Register Your Warranty On-Line at http://www.itvss.com/ Notice: Product improvements and enhancements are continuous; therefore the specifications and information contained in this document may change without notice. Eaton Corporation shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. No part

Summary of the content on the page No. 3

XT-40 & IT-RSS Installation IM01005012E 1 INTRODUCTION 1.1 Scope This installation manual contains the information necessary to install Eaton Corporation’s XT-40 and IT-RSS Surge Protective Devices (SPDs). System wiring and voltage information for these devices are provided in Sections 1.2 and 1.3. If you require further information regarding a particular installation, contact Power Quality Technical Support at 1-800-809-2772. 1.2 XT-40 Catalog Numbering System XT-40- 3Y101 Config

Summary of the content on the page No. 4

IM01005012E XT-40 & IT-RSS Installation 1.4 Safety Precautions A licensed/qualified electrician must complete all instructions and measurements described in this instruction in accordance with the U.S. National Electrical Code, state and local codes, or other applicable country codes. The U.S. National Electrical Code and state and local requirements (or other applicable country codes) supersede this instruction. Read and understand all instructions before beginning installation. WARNIN

Summary of the content on the page No. 5

XT-40 & IT-RSS Installation IM01005012E 2 INSTALLATION 2.1 Before Installation Perform or plan the following before installing the SPD: 1. Locate your electrical system’s applicable wiring diagram in Sections 2.2 & 2.3 2. Verify that your electrical system’s voltage and wiring configuration matches that of the SPD as shown on its label. 3. De-energize the SPD, and follow safe work practices to avoid an electrical shock hazard. 4. Ensure that a Neutral to Ground/Earth bond is present at

Summary of the content on the page No. 6

IM01005012E XT-40 & IT-RSS Installation 2.2 XT-40 Wiring Diagrams Single Phase (1P101, 1P201) Split Phase (1S101) PHASE A PHASE A Use Interrupt Device if connected to Phase B NEUTRAL NOT Neutral NETURAL CIRCUIT CIRCUIT or PHASE B PHASE B INTERRUPT INTERRUPT DEVICE DEVICE GROUND GROUND Solid bond between Ground/Earth and XT-40 XT-40 Neutral at service entrance or serving isolation transformer 3-Phase Wye (Star) (3Y101, 3Y201, 3Y300) 3-Phase Delta (No Neut.) (NN201, NN400, NN501) PHASE A

Summary of the content on the page No. 7

XT-40 & IT-RSS Installation IM01005012E 2.3 IT-RSS Wiring Diagram Split Phase – 288 Vac Phase to Phase Max. PHASE A CIRCUIT PHASE B INTERRUPT DEVICE GROUND IT-RSS 2.4 Installing Circuit Interrupt Devices The SPD must be connected to the electrical system through a 30 A circuit interrupt device as listed in Table 2-1. The circuit interrupt device can consist of fuses, individual circuit breakers (single breaker for each phase), or a multi-pole / single throw breaker. A pre-exist

Summary of the content on the page No. 8

IM01005012E XT-40 & IT-RSS Installation 2.5 Conduit Installation When planning the conduit installation, avoid using 90° elbows and keep the conduit run as short and straight as possible. See Figure 2-1. When applicable, use weatherproof (corrosion resistant) conduit and fittings to maintain the enclosure’s NEMA 4 or 4X rating. If the system utilizes an isolated ground, then the SPD’s housing must be isolated from ground using insulated conduit fittings. Figure 2-1. Conduit Installation

Summary of the content on the page No. 9

XT-40 & IT-RSS Installation IM01005012E Figure 2-2. XT-40 & IT-RSS Mounting Dimensions 5.58 (141.7) 4.73 (120.1) 0.75 (19.0) Internally 3.23 Threaded Conduit Fitting (82.0) 4.17 (105.9) 4.80 (121.9) 2.40 (61.0) Mounting Holes 1.77 Under Lid (4) (45.0) 1.38 3.15 (35.1) (80.0) Note: Remove cover to 2.87 2.48 gain access to the (73.0) (63.0) mounting hole shafts. 0.79 3.15 (80.0) (20.1) 0.25 Mounting Weight: 3 lb (6.4) Hole Shafts Dimensions: Inches (mm) 2.7 Wiring SPD to Electrical System

Summary of the content on the page No. 10

IM01005012E XT-40 & IT-RSS Installation 2.8 Power Up and System Checkout Apply system power and observe that the LED(s) on the front of the SPD should glow. One LED should glow for each Phase voltage being monitored. Should there be a significant difference in brightness, check the phase rotation of the panel and ensure that the SPD’s Phase wires are connected to the correct phase. Slight differences in brightness DO NOT indicate a faulty device, rather specification tolerance differences

Summary of the content on the page No. 11

XT-40 & IT-RSS Installation IM01005012E Notes: Rev. 1 – 2/2007 Page 9

Summary of the content on the page No. 12

Eaton Corporation 1000 Cherrington Parkway Moon Township, PA 15108-4312 USA http://www.itvss.com © 2007 Eaton Corporation For additional information please call: All Rights Reserved Power Quality Technical Support Center Publication No. IM01005012E 1-800-809-2772 Rev. 1 – February 2007


Alternative user manuals
# User manual Category Download
1 Eaton Electrical 10640205 User manual Power Supply 3
2 Eaton Electrical 164201420B User manual Power Supply 1
3 Eaton Electrical 6000L(XL) User manual Power Supply 29
4 Eaton Electrical 9125 User manual Power Supply 6
5 Eaton Electrical 10000L(XL) User manual Power Supply 5
6 Eaton Electrical 9135 User manual Power Supply 87
7 Eaton Electrical 0800-7500 User manual Power Supply 1
8 Eaton Electrical 9170+ User manual Power Supply 3
9 Eaton Electrical 9120 User manual Power Supply 72
10 Eaton Electrical Char-Lynn 110 User manual Power Supply 1
11 Eaton Electrical APR48 User manual Power Supply 325
12 Eaton Electrical Char-Lynn 450 Series User manual Power Supply 1
13 Eaton Electrical Char-Lynn 230 User manual Power Supply 0
14 Eaton Electrical Extended Battery Module (EBM) 9140 User manual Power Supply 4
15 Eaton Electrical Powerware 5125 User manual Power Supply 20
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2