APC SMART-UPS 10-40 KVA 380/400/415 V user manual

User manual for the device APC SMART-UPS 10-40 KVA 380/400/415 V

Device: APC SMART-UPS 10-40 KVA 380/400/415 V
Category: Power Supply
Manufacturer: APC
Size: 1.63 MB
Added : 7/6/2013
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for APC SMART-UPS 10-40 KVA 380/400/415 V. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with APC SMART-UPS 10-40 KVA 380/400/415 V.

For your convenience

If looking through the APC SMART-UPS 10-40 KVA 380/400/415 V user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual APC SMART-UPS 10-40 KVA 380/400/415 V on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual APC SMART-UPS 10-40 KVA 380/400/415 V to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
APC SMART-UPS 10-40 KVA 380/400/415 V User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual APC SMART-UPS 10-40 KVA 380/400/415 V but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to APC SMART-UPS 10-40 KVA 380/400/415 V. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation
®
Smart-UPS VT
XR Battery Enclosure
10-40 kVA 380/400/415 V
10-30 kVA 208/220 V
10-30 kVA 200/208 V

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Contents Safety ............................................................................... 1 IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Prepare for Floor-Anchoring (optional) ........................ 2 System arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Hole positions for a stand-alone UPS enclosure with L-shaped anchoring brackets . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

Final Mechanical Assembly.......................................... 20 Level the Enclosures (L-shaped Floor Anchoring Brackets) and Install Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Level the enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Install battery-securing and floor-anchoring brackets . . . . . . . . . 21 Reinstall the Enclosure Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Rein

Summary of the content on the page No. 5

Safety IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS Warning: • ALL safety instructions in the Safety Sheet (990-2822) must be read, understood, and followed when installing the UPS system. Failure to do so could result in equipment damage, serious injury, or death. • The UPS system does not have built-in disconnection devices for AC input/output and DC input. The customer must provide AC input/output over-current protection and an AC output disconnect device. • After the UPS has

Summary of the content on the page No. 6

Prepare for Floor-Anchoring (optional) Note: If floor anchoring and battery securing is required, read this section. If not, see “Prepare for Cables” on page 5. Note: Allow for enough working space behind the enclosure for electrical work to be carried out (e.g. if you want to install a conduit box or if you want to connect an XR Battery Enclosure at a later stage). Minimum rear clearance is 100 mm (3.93 in) and must comply with applicable national and local codes. 600 mm (23.6 in) is recomm

Summary of the content on the page No. 7

Hole positions for a stand-alone UPS enclosure with L-shaped anchoring brackets Note: Recommended minimum number of screws per enclosure for the L-shaped brackets is four; one in each corner. Recommended floor bolt size: M8. Model width: 352 mm (13.85 in) and 523 mm (20.59 in). Minimum rear clearance: Conduit box (if applicable) 100 mm (3.93 in) Floor anchoring hole 523 mm (20.59 in) 352 mm (13.85 in ) enclosure Note: Rear service clearance must comply with applicable national and local cod

Summary of the content on the page No. 8

352 mm (13.85 in) 523 mm (20.59 in) Hole positions for up to four UPS units in parallel with U-shaped anchoring brackets. Note: Recommended minimum number of floor screws for the below two configurations is 10. Model width: 352 mm (13.85 in). Top view Floor anchoring brackets 90 mm (3.54 in) 160 mm (6.29 in) 60 mm (2.36 in) 60 mm (2.36 in) 60 mm (2.36 in) 60 mm (2.36 in) 160 mm (6.29 in) 90 mm (3.54 in) 0 323 mm 1027 mm 675 mm 1379 mm (12.71 in) (40.41 in) (26.56 in) (54.26 in) M

Summary of the content on the page No. 9

Prepare for Cables Remove the front panel 1. Turn the screw to the right to the unlocked position. 2. Pull the top of the front  panel away from the UPS.  3. Lift the front panel free  of the two slots at the bottom of the enclosure. 4. Lift the battery compartment cover free of the two slots at the bottom of the enclosures (only in Japanese configurations).  Remove the top cover 1. Loosen the six screws of the top UPS front view XR Battery cover (four at the front and two at En

Summary of the content on the page No. 10

Remove the cable landing cover and bottom plates To access the cable landing area in the UPS and the XR Battery Enclosure(s), follow this procedure:  Cable  Cable landing landing cover plate cover plate + N  Conduit Conduit  box (upper Box part) (upper part)   Conduit box Conduit box  (bottom part) (bottom part)   Bottom plate Bottom plate 1. Loosen the six M4 screws from the cable landing cover plate on the UPS and the XR Battery Enclosure(s) and then remove the plates. 2. R

Summary of the content on the page No. 11

Remove the XR Battery Modules Heavy: Use two people to lift the battery modules. Note: The XR Battery Enclosures ship with two battery modules. All battery modules in the UPS and the XR Battery Enclosure(s) must be removed before interconnecting these enclosures. Note: When you remove battery modules, start from the highest row and work down.    1. Remove all battery securing brackets (used to secure the batteries during transport) by removing the M6 Torx screws. 2. Remove the blind plate.

Summary of the content on the page No. 12

Anchor the UPS and additional XR Battery or UPS Enclosure(s) (optional) Note: Enclosures can be kept apart or assembled and anchored with interconnection plates and brackets: SUVTOPT004: 352 mm (13.85 in) UPS enclosure to XR enclosure, SUVTOPT005: 523 mm (20.59 in) UPS enclosure to XR enclosure, or SUVTOPT006: XR enclosure to XR enclosure. Note: A baying kit includes three U-shaped floor anchoring brackets. In situations where a UPS or XR Battery Enclosure must be added to an existing confi

Summary of the content on the page No. 13

Note: The U-shaped interconnection brackets are 1-2 mm higher than the opening below the enclosure to inactivate the casters. Therefore, the enclosure must be tilted when placing the U- shaped interconnection brackets under the enclosure. 3. In each side of the same enclosure insert a maximum of nine and a minimum of two M8 screws (not provided) through holes in the bottom of the enclosure and through holes in the U-shaped floor anchoring brackets, and into the pre-drilled floor holes. 

Summary of the content on the page No. 14

6. Insert the XR Battery Enclosure rear view UPS rear view interconnection plates between the two  enclosures. One is  positioned toward the front and the other   toward the rear. Note  how the “wings” on the interconnection plates rest in slots at the top of the inner panel on the XR Battery Enclosure. 7. Align the two  enclosures and level the three marked rows of bolt holes in one  enclosure with the  holes in the adjacent enclosure.   8. Push the two enclosures f

Summary of the content on the page No. 15

Run the Cables Connect Power in Installations with Busbars Warning: Before carrying out the steps below, you must follow the Total Power Off procedure in the Operation manual. Install isolators See “Specifications” on page 23 for torque specification. The isolators separate the baying kit busbar from the six vertical busbars in each XR Battery Enclosure, and the (+), N, and (-) busbars in the UPS. This is how the isolators are fitted to their busbar:    1. Guide the isolator busbar + N th

Summary of the content on the page No. 16

Install busbars 523 mm (20.59 in) UPS System with the UPS placed to the left (seen from the front). XR2 XR1 UPS   N  +    1. Install the following baying kit busbars between the UPS and XR1: 880-1607 between the vertical busbar N on the UPS and busbar 4 on XR1 880-1606 between the vertical busbar (+) on the UPS and busbar 1 on XR1 880-1605 between busbar (-) on the UPS and busbar 6 on XR1 2. Install the following baying kit busbars between the two XR Battery Enclosures: 880-0926 betwee

Summary of the content on the page No. 17

523 mm (20.59 in) UPS system with the UPS placed to the right (seen from the front). UPS XR1 XR2   N +     1. Install the following baying kit busbars between the UPS and XR1: 880-1607 between the vertical busbar N on the UPS and busbar 3 on XR1 880-1605 between vertical busbar (+) on the UPS and busbar 1 on XR1 880-1606 between vertical busbar (-) on the UPS and busbar 6 on XR1 2. Install the following baying kit busbars between the two XR Battery Enclosures: 880-0926 between the vertic

Summary of the content on the page No. 18

352 mm (13.85 in) UPS system with the UPS placed to the right (seen from the front). XR2 XR1 UPS   N  +    1. Install the following baying kit busbars between the UPS and XR1: 880-1604 between the vertical busbar N on the UPS and busbar 4 on XR1 880-0939 between the vertical busbar (+) on the UPS and busbar 1 on XR1 880-1604 between the vertical busbar (-) on the UPS and busbar 6 on XR1 2. Install the following baying kit busbars between two XR Battery Enclosures: 880-0926 between the v

Summary of the content on the page No. 19

352 mm (13.85 in) UPS system with the UPS placed to the left (seen from the front). UPS XR1 XR2   N   +   1. Install the following baying kit busbars between the UPS and XR1: 880-1604 between the vertical busbar N on the UPS and busbar 3 on XR1 880-1604 between the vertical busbar (+) on the UPS and busbar 1 on XR1 880-0939 between the vertical busbar (-) on the UPS and busbar 6 on XR1 2. Install the following baying kit busbars between two XR Battery Enclosures: 880-0926 between the ver

Summary of the content on the page No. 20

Connect Power in Installations with Cables Install power cables See “Recommended cable sizes” on page 23. Install power cables between the UPS and the XR Battery Enclosure. 1. In the UPS, feed the cable XR Battery Enclosure rear view UPS rear view. up through the conduit box or through the transparent cable route bracket (not shown). 2. Connect the Bat+, Bat-, and N cables to the busbars in the UPS. 3. Secure the cables to the perforated bracket with cable ties. 4. Equip the cable w


Alternative user manuals
# User manual Category Download
1 APC 208 Vac User manual Power Supply 8
2 APC 1400XLT User manual Power Supply 23
3 APC 15A User manual Power Supply 0
4 APC 120V User manual Power Supply 5
5 APC 2200XLT User manual Power Supply 24
6 APC 2000XL User manual Power Supply 15
7 APC 1000VA User manual Power Supply 24
8 APC 1500 VA User manual Power Supply 46
9 APC 300 User manual Power Supply 404
10 APC 5000VA User manual Power Supply 60
11 APC 500 User manual Power Supply 26
12 APC 3000VA User manual Power Supply 12
13 APC 3000T User manual Power Supply 1
14 APC 600 User manual Power Supply 64
15 APC 2AP9604S User manual Power Supply 1
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2