APC Smart UPS 3000 VA user manual

User manual for the device APC Smart UPS 3000 VA

Device: APC Smart UPS 3000 VA
Category: Power Supply
Manufacturer: APC
Size: 1.86 MB
Added : 7/6/2013
Number of pages: 19
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for APC Smart UPS 3000 VA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with APC Smart UPS 3000 VA.

For your convenience

If looking through the APC Smart UPS 3000 VA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual APC Smart UPS 3000 VA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual APC Smart UPS 3000 VA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
APC Smart UPS 3000 VA User manual - Online PDF
Advertisement
« Page 1 of 19 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual APC Smart UPS 3000 VA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to APC Smart UPS 3000 VA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1





User Manual
English
   

APC Smart APC Smart APC Smart APC Smart- -U - -UPS UPS UPS PS

1500/3000 VA 120/230 Vac 1500/3000 VA 120/230 Vac 1500/3000 VA 120/230 Vac 1500/3000 VA 120/230 Vac

Mod Modu ular lar
Mod Modu ular lar
Uninterruptible Power Supply Uninterruptible Power Supply Uninterruptible Power Supply Uninterruptible Power Supply










990-1704 01/2004

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Introduction This APC Smart-UPS is a modular Uninterruptible Power Supply (UPS) for high availability applications such as data centers and mission critical processes, designed to prevent blackouts, brownouts, sags, and surges from reaching your equipment. The UPS filters small utility line fluctua- tions and isolates your equipment from large disturbances by internally disconnecting from the utility line. The UPS provides continuous power from its internal battery until the utility line r

Summary of the content on the page No. 4

Mount the UPS in the Rack and Connect the Battery Attention: Install the rails following the instructions in the rail kit.       Rear 2

Summary of the content on the page No. 5

Tower Configuration  Press and hold the black switch (see location  designation on UPS) to the right while removing the power processing module.   Note: Place the UPS in the final operating loca- tion prior to module reinstallation.  Snap the display bezel out the rear to begin  rotation. Rear 3

Summary of the content on the page No. 6

2: START UP Connect Equipment to the UPS Rear Panels 1500 VA, 120 V: 1500 VA, 230 V: 3000 VA, 120 V: 3000 VA, 230 V: Note: • The ‘outlet groups’ can be controlled through the network software. See Network Management Card documentation. • A laser printer draws significantly more power than other types of equipment and may overload the UPS. Connect the UPS to the Network (if Applicable) Network Connectors Serial Port USB Port Ethernet Port Note: • Use only the supplied

Summary of the content on the page No. 7

The battery will charge to full capacity during the first few hours of normal operation. Do not expect full ‘on battery’ capability during this initial charge period. 2. After the UPS has ended the immediate self-test with online LED illumination, check the front display for any fault indicators (see Troubleshooting). 3. 120 V models: Check the site wiring fault LED located on the rear panel. It will be illuminated if the UPS is plugged into an improperly wired utility power outlet (see T

Summary of the content on the page No. 8

3: BASIC OPERATION Front Display Panel INDICATOR DESCRIPTION Online The UPS is supplying utility power to the connected equipment. AVR The UPS is compensating for either a high or low utility voltage. On Battery The UPS is supplying battery power to the connected equipment. Overload The connected loads are drawing more than the UPS power rating. Bypass The connected loads are being powered directly by the utility power connection and not

Summary of the content on the page No. 9

FEATURE FUNCTION Self-Test Automatic: The UPS performs a self-test automatically when turned on, and every two weeks thereafter (by default). During the self-test, the UPS briefly operates the connected equipment on battery. Manual: Press and hold the button for a few seconds to initiate the self- test. Cold Start Supply battery power to the UPS and connected equipment in the absence of utility voltage (see Troubleshooting). Press the button for one second and release. The UPS will

Summary of the content on the page No. 10

4: USER CONFIGURABLE ITEMS NOTE: SETTINGS ARE MADE THROUGH THE SUPPLIED POWERCHUTE SOFTWARE OR THE NETWORK INTERFACE CONNECTION. REFER TO THE SOFTWARE HELP GUIDES FOR DETAILS. FACTORY USER SELECTABLE FUNCTION DESCRIPTION DEFAULT CHOICES Automatic Self-Test Every 14 days Every 14 days This function sets the interval at which the (336 hours) (336 hours), UPS will execute a self-test. Every 7 days (168 hours), On Startup Only, No Self-Test UPS ID UPS_IDEN Up to eight characters

Summary of the content on the page No. 11

NOTE: SETTINGS ARE MADE THROUGH THE SUPPLIED POWERCHUTE SOFTWARE OR THE NETWORK INTERFACE CONNECTION. REFER TO THE SOFTWARE HELP GUIDES FOR DETAILS. FACTORY USER SELECTABLE FUNCTION DESCRIPTION DEFAULT CHOICES High Transfer Point 120 V: 120 V: If the utility voltage is usually high and the 127 VAC 127, 130, 133, 136 VAC connected equipment is specified to operate with input voltages this high, set the high 230 V: 230V: transfer point higher to avoid unnecessary 253 VAC 25

Summary of the content on the page No. 12

5: STORAGE, MAINTENANCE, SHIPPING, AND SERVICE Storage Store the UPS covered in a cool, dry location, with the battery fully charged. At -15 to +30 °C (+5 to +86 °F), charge the UPS battery every six months. At +30 to +45 °C (+86 to +113 °F), charge the UPS battery every three months. Battery Module Maintenance The UPS battery life differs based on usage and environment. Consider replacing the battery every three years. This UPS has an easy to replace, hot-swappable battery. Replacemen

Summary of the content on the page No. 13

Shipping 1. Shut down and disconnect any equipment attached to the UPS. 2. Shut down the UPS, and disconnect the UPS from the utility power outlet. 3. Unplug the battery connector. For further shipping instructions and to obtain appropriate packing materials, contact APC (see Contact Infor- mation). Service If the UPS requires service do not return it to the dealer. Follow these steps: 1. Review the problems discussed in Troubleshooting to eliminate common problems. 2. If the problem

Summary of the content on the page No. 14

6: TROUBLESHOOTING Use the chart below to solve minor UPS installation and operation problems. Refer to APC for assis- tance with complex UPS problems. PROBLEM AND/OR POSSIBLE SOLUTION CAUSE UPS WILL NOT TURN ON UPS not connected to utility Check that the power cord from the UPS to the utility power supply is se- power supply. curely connected at both ends. Battery not connected prop- Check that the battery connector is fully snapped into position. erly. Very low or no utility voltag

Summary of the content on the page No. 15

PROBLEM AND/OR POSSIBLE SOLUTION CAUSE NOT ALL OUTLETS ARE POWERED One or more of the outlet Access the UPS control panel via the network interface connection and groups (labeled ‘1’, ‘2’, and check the status of the outlets. If the settings are not what are expected, ‘3’) are shut off via the net- change them accordingly and review security settings (password, etc.). work interface connection. 3000 VA, 120 V model only: The three outlet groups are individually protected by circuit bre

Summary of the content on the page No. 16

PROBLEM AND/OR POSSIBLE SOLUTION CAUSE THE OVERLOAD LED IS ILLUMINATED AND THE UPS EMITS A SUSTAINED ALARM TONE The UPS is overloaded. The The connected equipment exceeds the specified “maximum load.” connected equipment is draw- The alarm remains on until the overload is removed. Disconnect nonessen- ing more VA or more Watts tial equipment from the UPS to eliminate the overload. than the UPS can sustain. The UPS continues to supply power as long as it is online and the circuit break

Summary of the content on the page No. 17

PROBLEM AND/OR POSSIBLE SOLUTION CAUSE THE BYPASS LED IS ILLUMINATED The UPS has briefly directed Nothing. This is a normal behavior of the UPS during startup. power around the power proc- essing module during a startup sequence. The UPS has directed power Replace the power processing module (See Storage, Maintenance, around the power processing Transporting, and Service). module because of an internal fault. THERE IS NO UTILITY POWER Use the Cold Start feature to supply power to

Summary of the content on the page No. 18

7: REGULATORY AND WARRANTY INFORMATION 120V models This equipment has been tested and found to comply with the limits for a Class A digital device, pur- suant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction

Summary of the content on the page No. 19

Limited Warranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support. Products must be returned with transportation charges prepaid and must


Alternative user manuals
# User manual Category Download
1 APC Smart UPS 3000 VA User manual Battery Charger 11
2 APC Smart UPS 3000 VA User manual Computer Accessories 1
3 APC 208 Vac User manual Power Supply 8
4 APC 1400XLT User manual Power Supply 23
5 APC 15A User manual Power Supply 0
6 APC 120V User manual Power Supply 5
7 APC 2200XLT User manual Power Supply 24
8 APC 2000XL User manual Power Supply 15
9 APC 1000VA User manual Power Supply 24
10 APC 1500 VA User manual Power Supply 46
11 APC 300 User manual Power Supply 404
12 APC 5000VA User manual Power Supply 60
13 APC 500 User manual Power Supply 26
14 APC 3000VA User manual Power Supply 12
15 APC 3000T User manual Power Supply 1
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2