APC 5000VA user manual

User manual for the device APC 5000VA

Device: APC 5000VA
Category: Power Supply
Manufacturer: APC
Size: 0.09 MB
Added : 7/6/2013
Number of pages: 13
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for APC 5000VA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with APC 5000VA.

For your convenience

If looking through the APC 5000VA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual APC 5000VA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual APC 5000VA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
APC 5000VA User manual - Online PDF
Advertisement
« Page 1 of 13 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual APC 5000VA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to APC 5000VA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM
APC Smart-UPS RT

BID SPECIFICATIONS FOR
3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC
Uninterruptible Power Supply


PART 1 - GENERAL
1.1 SUMMARY
A. This specification describes the operation and functionality of a continuous duty, single-
phase, solid-state, static Uninterruptible Power System (UPS) hereafter referred to as
the UPS.
B. The UPS utilizes double conversion online topology designed to protect electronic
equipment by sup

Summary of the content on the page No. 2

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM H. Configuration Specifics: The UPS is available in one of the following configurations: MODEL SKU # TOWER APC Smart-UPS RT 3000VA RM 230V SURT3000XLI APC Smart-UPS RT 5000VA RM 230V SURT5000XLI APC Smart-UPS RT 6000VA RM 230V SURT6000XLI RACK MOUNT APC Smart-UPS RT 3000VA RM 230V SURT3000RMXLI APC Smart-UPS RT 5000VA RM 230V SURT5000RMXLI APC Smart-UPS RT 6000VA RM 230V SURT6000RMXLI 1.2 STANDARDS A. EN50091-1 B. EN50091-2 C.

Summary of the content on the page No. 3

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM A. Online: The input PFC power stage and the output power stage (inverter) shall operate in an on-line manner to continuously regulate power to the critical load. The input PFC stage shall be capable of full battery recharge while simultaneously providing regulated power to the load for all line and load conditions within the range of the UPS specifications. B. On Battery: Upon failure of the AC input source, the critical load shall continue

Summary of the content on the page No. 4

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM 2.1 MECHANICAL DESIGN A. The UPS is contained in a rugged steel cabinet with two plastic front bezels; B. The UPS dimensions are 13 x 43 x 66cm (5.1 x 17 x 26 in.); C. The UPS cabinet is capable of conversion between Tower and Rack-Mount configurations; 2.2 SYSTEM CHARACTERISTICS A. System Capacity: 1. The system is rated to be capable of supporting: a. 3000VA or 2100W whichever limit is reached first (for the 3000VA model). b. 5000VA o

Summary of the content on the page No. 5

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM 3. Output frequency: 50/60 +/- 3Hz tracking or 50/60 +/- 0.1Hz tracking (user selectable); 4. AC output voltage distortion: Max. 2% @ 100% linear load; Max. 5% @ 100% non-linear Load; 5. AC output static voltage regulation: +/-1%; 6. AC output dynamic voltage regulation: +/- 8% maximum for 100% load step at less than 10ms recovery time; 7. Overload Rating: a. Online: 105% - infinite; 125% - 1 minute; 150% - 30 seconds; b. I

Summary of the content on the page No. 6

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM C. Input Current Limit: 1. The input converter shall control and limit the input current draw from utility to 150% of the UPS output. During conditions where input current limit is active, the UPS shall be able to support 100% load, charge batteries at 10% of the UPS output rating, and provide voltage regulation with mains deviation of up to +/- 20% of the nominal input voltage. 2. In cases where the source voltage to the UPS is nominal a

Summary of the content on the page No. 7

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM condition is removed from the critical bus output of the system. Automatic transfers of load to bypass also take place if for any reason the UPS cannot support the critical bus. D. Manual Transfers: Manually initiated transfers to and from bypass may be initiated through the UPS computer interface (via serial or USB communications) or by engaging the bypass switch on the rear panel of the unit. 2.7 BATTERY A. The UPS battery system is compr

Summary of the content on the page No. 8

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM 6. Self-diagnostics, self-test and proactive fault detection; 7. Communication to the host server via serial port; 8. Communication to the Network Interface Card or another SmartSlot accessory card if equipped. 9. Etc. B. Display/Control Unit: A display/control comprised of 16 LEDs and 2 pushbutton switches is located on the front side of the UPS. The display/control unit may be turned 90 degrees clockwise or counterclockwise to acc

Summary of the content on the page No. 9

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM 6. The UPS is in fault state; 7. The battery needs to be replaced; 8. The battery capacity/utility voltage LED bar G. Audible Alarms: Using audio signal, the UPS will notify the user about important events. The following is the list of distinct audio alarms: 1. The UPS is on battery; 2. The UPS is on battery and the remaining battery capacity is low; 3. The UPS has shutdown due to low battery capacity; 4. The battery needs

Summary of the content on the page No. 10

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM 3.2 SOFTWARE AND CONNECTIVITY A. Network Adaptor: APC SmartSlot Network Management Card shall allow one or more network management systems (NMS) to monitor and manage the UPS in TCP/IP network environments. B. Unattended Shutdown 1. The UPS, in conjunction with a network interface card, shall be capable of gracefully shutting down one or more operating systems during when the UPS is on battery mode. 2. The UPS is also capable of using

Summary of the content on the page No. 11

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM 7. TurboLinux v.7.0 and 8.0 8. Novell Netware 6.0 with Support Pack 1 9. Novell Netware 6.5 10. Novell Netware 5.1 with Support Pack 3 or above (using PowerChute Business Edition v6.2.2 agent) 11. Sun Solaris 8 and 9 PART 4 - Part 4 - EXECUTION 4.1 FACTORY ASSISTED START-UP If a factory assisted UPS start-up is requested, factory trained service personnel shall perform the following inspections, test procedures, and on-s

Summary of the content on the page No. 12

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM 1. Ensure proper system start-up. 2. Verify proper firmware control functions. 3. Verify proper firmware bypass operation. 4. Verify proper bypass switch operation (where applicable). 5. Verify proper inverter operation and regulation circuits. 6. Simulate utility power failure. 7. Verify proper charger operation. 8. Document, sign, and date all test results. E. On-Site Operational Training: During the factory assisted star

Summary of the content on the page No. 13

CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM identification and operation, system controls and adjustment, preventative maintenance, and troubleshooting. End Of Section 16611 CSI SECTION 16611 STATIC UNINTERRUPTIBLE SYSTEM


Alternative user manuals
# User manual Category Download
1 APC 208 Vac User manual Power Supply 8
2 APC 1400XLT User manual Power Supply 23
3 APC 15A User manual Power Supply 0
4 APC 120V User manual Power Supply 5
5 APC 2200XLT User manual Power Supply 24
6 APC 2000XL User manual Power Supply 15
7 APC 1000VA User manual Power Supply 24
8 APC 1500 VA User manual Power Supply 46
9 APC 300 User manual Power Supply 404
10 APC 500 User manual Power Supply 26
11 APC 3000VA User manual Power Supply 12
12 APC 3000T User manual Power Supply 1
13 APC 600 User manual Power Supply 64
14 APC 2AP9604S User manual Power Supply 1
15 APC 5000T User manual Power Supply 0
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2