American Power Conversion PD60H5HK1 user manual

User manual for the device American Power Conversion PD60H5HK1

Device: American Power Conversion PD60H5HK1
Category: Power Supply
Manufacturer: American Power Conversion
Size: 1.97 MB
Added : 3/12/2014
Number of pages: 76
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for American Power Conversion PD60H5HK1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with American Power Conversion PD60H5HK1.

For your convenience

If looking through the American Power Conversion PD60H5HK1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual American Power Conversion PD60H5HK1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual American Power Conversion PD60H5HK1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
American Power Conversion PD60H5HK1 User manual - Online PDF
Advertisement
« Page 1 of 76 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual American Power Conversion PD60H5HK1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to American Power Conversion PD60H5HK1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

60kW InfraStruXure PDU
PD60H5HK1
PDRPPH1000
Operation and Configuration
400/230V

Summary of the content on the page No. 2

Summary of the content on the page No. 3

About This Manual Audience This manual is intended for end-users of a 60kW InfraStruXure PDU. It covers the operation, customization, and quick configuration of the PDU, and includes basic InfraStruXure system operation. Companion manuals For additional information about the InfraStruXure system, see the Installation and Start-Up manual (990-1637B) included with the PDU. It covers the installation and start-up of the PDU, power distribution to the rack, and power distribution within the rac

Summary of the content on the page No. 4

Summary of the content on the page No. 5

Contents Safety ......................................................................1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Save these instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety symbols used in this manual . . . . . . . . . . . . . . . . . . . 1 Cross-reference symbols used in this manual . . . . . . . . . . . . . 1 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 6

Alarms Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 View Active Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Alarm/Event Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Alarm Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Alarm Beeper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 PDU Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Summary of the content on the page No. 7

Communication Configuration................................31 InfraStruXure PDU Management Options. . . . . . . . . . . . . . . . . 31 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 InfraStruXure Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Network management interfaces . . . . . . . . . . . . . . . . . . . . 31 Configuring the InfraStruXure Manager . . . . . . . . . . . . . . . . . . 32 Configuring the Network Management Interface . . . .

Summary of the content on the page No. 8

How to Test the Emergency Power Off Switch . . . . . . . . . . . . . 49 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Testing the switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Emergency Power Off (EPO) . . . . . . . . . . . . . . . . . . . . . . . 51 How to Download Firmware Upgrades . . . . . . . . . . . . . . . . . . 52 Specifications ........................................................ 55 Product Information ...................

Summary of the content on the page No. 9

Safety Overview Save these instructions This manual contains important instructions that must be followed during installation, operation, and maintenance of the PDU. Safety symbols used in this manual Indicates an electrical hazard, which, if not avoided, could result in injury or death. Electrical Hazard Indicates a hazard, which, if not avoided, could result in personal injury or damage to product or other property. Warning Indicates a potential hazard which could result in damage to produc

Summary of the content on the page No. 10

Warnings Unpacking/moving DO NOT tilt the PDU greater than 45° from its vertical axis. Never lay the PDU on its side. Installation/maintenance Only a certified electrician can perform these tasks: • Connect the PDU to its power source • Connect a switch to the EPO interface on the PDU Only a certified electrician or an APC Field Service Engineer can perform maintenance of the PDU. When you connect the PDU to its power source, you must install a 125A circuit breaker to protect the PDU against o

Summary of the content on the page No. 11

Safety Emergency Power Off (EPO) This InfraStruXure PDU is provided with an Emergency Power Off switch connection. When this EPO switch is energized, electrical power to the units is de-energized and the system will not transfer to on-battery operation. EPO can be achieved with either a contact closure or application of an external 24VAC or 24VDC from a SELV or PELV source. It’s important to note that hazardous voltage from the Mains voltage must be isolated from the contact closure or 24VAC

Summary of the content on the page No. 12

Summary of the content on the page No. 13

PDU Display Interface Overview Use the display interface to configure settings, set alarm thresholds, and provide audible and visual alarms. Load Powered ESC Check Log ? Bypass Alarm         Load Powered LED When green, all output phases are within the limits specified by the output alarm limit thresholds.  Check Log LED When yellow, at least one new alarm condition has been detected.  Bypass LED Not used on this model PDU.  Alarm LED When red, an alarm condition exists.  LCD V

Summary of the content on the page No. 14

PDU Display Interface Top-level status screens After displaying a brief start-up screen after system start-up, the display interface scrolls automatically and continuously through four screens of basic status information. Press the Up and Down arrow keys to interrupt the automatic scrolling to view a specific status screen. Volts In Volts Out Load Current L1-2: 000 L1: 000 L1: 000 Neut: 000 L2-3: 000 L2: 000 L2: 000 L3-1: 000 L3: 000 L3: 000 Total Output Loading No Active Alarms kW: 000 PF: 00

Summary of the content on the page No. 15

PDU Display Interface On some screens, continue arrows ( indicate that there  System/Network are additional screens to view in the category. Press the Up Electrical Configuration Panel Configuration or Down arrow key to view the additional screens. Manufacturer Data  Product Data Factory Defaults Firmware Updates Password-protected screens When configuring or changing settings, you will be prompted for your password. To enter your password: 1. Press the Up or Down arrow key until the corr

Summary of the content on the page No. 16

Load-Meter Screen From the Load-Meter screen, you can select the following items: Total Load by Phase The load supported by each phase in kVA, in RMS current (Irms), and as a percentage of the maximum allowable load (%LD). Total Load Summary For the total load supported: • kW: The power provided, in kilowatts. • kVA: The actual power drawn by the load, in kilovolt-amperes. • Freq: Frequency • PF: The power factor (kW/kVA), which affects the power available to the load. • %LD: The load as a p

Summary of the content on the page No. 17

Volt-Meter Screen From the Volt-Meter screen, you can select the following items: Output Voltage Displays each phase-to-phase output voltage (e.g., L1-2 for phase L1 to phase L2) and each phase-to-neutral output voltage (e.g., L1 for phase L1 to neutral). Input Voltage Displays each phase-to-phase input voltage (e.g., L1-2 for phase L1 to L2), or each phase-to-neutral input voltage (e.g., L1 for phase L1 to neutral). 60kW InfraStruXure PDU—Operation and Configuration 9

Summary of the content on the page No. 18

Contacts Screen Overview The PDU can monitor external contact closure events. Possible applications include the following: • Magnetic contact switches • Window foil • Tamper switches • Heat detectors • Water sensors • Pressure sensors • Building smoke and fire detection systems You can set input contacts to cause alarm conditions based on their current state and a user-defined normal state. Relay outputs can map internal alarms and events to outside devices. Use the Contacts screen to display

Summary of the content on the page No. 19

PDU Display Interface Alarm Relay Map Configure the relay outputs, using the Alarm Relay Map. Each Alarm Map corresponds to a relay output. For example, Alarm Map 01of04 corresponds to the first of four relay outputs. The second line, in brackets [ ], lists the items that you have selected to map to the selected relay/ The third line allows you to select the alarms to which you want to map the relay: • Any Load (L)—Maps to over- or under-current alarms for circuit breaker panels and branch

Summary of the content on the page No. 20

PDU Display Interface How to connect contacts to the PDU monitoring unit 1. Choose one or more contact numbers on the user connection plate to which you will connect the contacts. The user connection plate connects to the User/EPO port on the PDU monitoring unit. 2. From the PDU display interface: a. Press the ESC or ENTER key to go to the top-level menu screen. b. Select Contacts on the top-level menu screen, and press the ENTER key. Load-Meter Alarms Volt-Meter Panel Config Contacts Help Br


Alternative user manuals
# User manual Category Download
1 American Power Conversion 100 User manual Power Supply 0
2 American Power Conversion 120 User manual Power Supply 0
3 American Power Conversion 110, 120, 230 User manual Power Supply 0
4 American Power Conversion 10000 VA User manual Power Supply 1
5 American Power Conversion 1000, 1100, 1400 User manual Power Supply 2
6 American Power Conversion 110Vac User manual Power Supply 0
7 American Power Conversion 1400XLT User manual Power Supply 0
8 American Power Conversion 1050 User manual Power Supply 0
9 American Power Conversion 10-40kW 208/480V User manual Power Supply 0
10 American Power Conversion 2200 VA User manual Power Supply 0
11 American Power Conversion 2200XLT User manual Power Supply 0
12 American Power Conversion 208/220 User manual Power Supply 0
13 American Power Conversion 20000 VA User manual Power Supply 3
14 American Power Conversion 2200VA 3U User manual Power Supply 0
15 American Power Conversion 230 VAC User manual Power Supply 0
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2