American Power Conversion 500 VA user manual

User manual for the device American Power Conversion 500 VA

Device: American Power Conversion 500 VA
Category: Power Supply
Manufacturer: American Power Conversion
Size: 1.07 MB
Added : 11/10/2014
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for American Power Conversion 500 VA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with American Power Conversion 500 VA.

For your convenience

If looking through the American Power Conversion 500 VA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual American Power Conversion 500 VA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual American Power Conversion 500 VA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
American Power Conversion 500 VA User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual American Power Conversion 500 VA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to American Power Conversion 500 VA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



User Manual
English
®

APC Smart-UPS

500 VA
100 VAC
750 VA
100/120/230 VAC

Tower
Uninterruptible Power Supply









990-1587A 12/2005

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sags, and surges from reaching your equipment. The uninterruptible power supply (UPS) filters small util- ity line fluctuations and isolates your equipment from large disturbances by internally disconnecting from the utility line. The UPS provides continuous power from its internal battery until the utility line returns to safe levels or the battery is fully discharged. 1: INSTALLATION T

Summary of the content on the page No. 4

Connect Equipment and Power to the UPS 1. Connect equipment to the UPS. Note: A laser printer draws significantly more power than other types of equipment and may overload the UPS. 2. Add accessories to the Smart-Slot (optional). 3. Connect ground leads to the TVSS screw (optional). To make the connection, loosen the screw and connect the surge suppression device ground lead. Tighten the screw to secure the lead. 4. Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avo

Summary of the content on the page No. 5

2: OPERATION Front Display Panel INDICATOR DESCRIPTION Online The UPS is supplying utility power to the connected equipment. AVR Trim The UPS is compensating for a high utility voltage. AVR Boost The UPS is compensating for a low utility voltage. On Battery The UPS is supplying battery power to the connected equipment. Overload The connected loads are drawing more than the UPS power rating. Replace Battery/ The battery is disconnected or must be replaced. Battery D

Summary of the content on the page No. 6

FEATURE FUNCTION Self-Test Automatic: The UPS performs a self-test automatically when turned on, and every two weeks thereafter (by default). During the self-test, the UPS briefly operates the connected equipment on battery. Manual: Press and hold the button for a few seconds to initiate the self- test. Cold Start 120V and 230V models only: Supply battery power to the UPS and connected equipment in the absence of utility voltage (see Troubleshooting). Press the button for one second

Summary of the content on the page No. 7

3: USER CONFIGURABLE ITEMS NOTE: SETTINGS ARE ADJUSTED THROUGH POWERCHUTE SOFTWARE OR OPTIONAL SMART SLOT ACCESSORY CARDS. FACTORY USER SELECTABLE FUNCTION DESCRIPTION DEFAULT CHOICES Automatic Self- Every 14 days Every 7 days Set the interval at which the UPS will Test (336 hours) (168 hours), execute a self-test. On Startup Only, No Self-Test UPS ID UPS_IDEN Up to eight charac- Uniquely identify the UPS, (i.e. server ters (alphanumeric) name or location) for network man- ag

Summary of the content on the page No. 8

NOTE: SETTINGS ARE ADJUSTED THROUGH POWERCHUTE SOFTWARE OR OPTIONAL SMART SLOT ACCESSORY CARDS. FACTORY USER SELECTABLE FUNCTION DESCRIPTION DEFAULT CHOICES High Transfer 100V model: 100V model: Set the high transfer point higher to Point 108 Vac 108, 110, 112, 114 avoid unnecessary battery usage when Vac the utility voltage is usually high and the connected equipment is specified 120V model: 120V model: to operate with input voltages this 127 Vac 127, 130, 133, 136 high. Vac

Summary of the content on the page No. 9

4: STORAGE, MAINTENANCE, AND SHIPPING Storage Store the UPS covered in a cool, dry location, with the battery fully charged. At -15 to +30 °C (+5 to +86 °F), charge the UPS battery every six months. At +30 to +45 °C (+86 to +113 °F), charge the UPS battery every three months. Battery Module Maintenance The UPS battery life differs based on usage and environment. Consider replacing the battery every three years. This UPS has an easy to replace, hot-swappable battery. Replacement is a sa

Summary of the content on the page No. 10

5: TROUBLESHOOTING Use the chart below to solve minor UPS installation and operation problems. Refer to www.apc.com with complex UPS problems. PROBLEM AND/OR POSSIBLE SOLUTION CAUSE UPS WILL NOT TURN ON UPS not connected to utility Check that the power cord from the UPS to the utility power supply is se- power supply. curely connected at both ends. Battery not connected prop- Check that battery connector on the rear panel is fully snapped into position. erly. Very low or no utility v

Summary of the content on the page No. 11

PROBLEM AND/OR POSSIBLE SOLUTION CAUSE THE OVERLOAD LED IS ILLUMINATED AND THE UPS EMITS A SUSTAINED ALARM TONE The UPS is overloaded. The The connected equipment exceeds the specified “maximum load.” connected equipment is draw- The alarm remains on until the overload is removed. Disconnect nonessen- ing more VA than the UPS can tial equipment from the UPS to eliminate the overload. sustain. The UPS continues to supply power as long as it is online and the circuit breaker does not tri

Summary of the content on the page No. 12

PROBLEM AND/OR POSSIBLE SOLUTION CAUSE BATTERY CHARGE AND LOAD LED BARGRAPHS FLASH SIMULTANEOUSLY The UPS has shutdown. The Check that the room temperature is within the specified limits for operation. internal temperature of the Check that the UPS is properly installed, allowing for adequate ventilation UPS has exceeded the allow- (see Position the UPS). able threshold for safe opera- tion. Allow the UPS to cool down. Restart the UPS. If the problem continues, contact APC (see Contac

Summary of the content on the page No. 13

6: REGULATORY AND WARRANTY INFORMATION 100V/120V models This equipment has been tested and found to comply with the limits for a Class A digital device, pur- suant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruc

Summary of the content on the page No. 14

Limited Warranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support. Products must be returned with transportation charges prepaid and must


Alternative user manuals
# User manual Category Download
1 American Power Conversion 100 User manual Power Supply 0
2 American Power Conversion 120 User manual Power Supply 0
3 American Power Conversion 110, 120, 230 User manual Power Supply 0
4 American Power Conversion 10000 VA User manual Power Supply 1
5 American Power Conversion 1000, 1100, 1400 User manual Power Supply 2
6 American Power Conversion 110Vac User manual Power Supply 0
7 American Power Conversion 1400XLT User manual Power Supply 0
8 American Power Conversion 1050 User manual Power Supply 0
9 American Power Conversion 10-40kW 208/480V User manual Power Supply 0
10 American Power Conversion 2200 VA User manual Power Supply 0
11 American Power Conversion 2200XLT User manual Power Supply 0
12 American Power Conversion 208/220 User manual Power Supply 0
13 American Power Conversion 20000 VA User manual Power Supply 3
14 American Power Conversion 2200VA 3U User manual Power Supply 0
15 American Power Conversion 230 VAC User manual Power Supply 0
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2