American Power Conversion 2200VA 3U user manual

User manual for the device American Power Conversion 2200VA 3U

Device: American Power Conversion 2200VA 3U
Category: Power Supply
Manufacturer: American Power Conversion
Size: 0.51 MB
Added : 11/10/2014
Number of pages: 25
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for American Power Conversion 2200VA 3U. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with American Power Conversion 2200VA 3U.

For your convenience

If looking through the American Power Conversion 2200VA 3U user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual American Power Conversion 2200VA 3U on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual American Power Conversion 2200VA 3U to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
American Power Conversion 2200VA 3U User manual - Online PDF
Advertisement
« Page 1 of 25 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual American Power Conversion 2200VA 3U but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to American Power Conversion 2200VA 3U. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


User’s Manual
English
®

APC Smart-UPS
2200VA/3000VA 3U Rack Mount
Uninterruptible Power Supply
230VAC/120VAC
990-1055A, 08/01

Summary of the content on the page No. 2

Summary of the content on the page No. 3

1: SAFETY INFORMATION American Power Conversion Corporation (APC) is the leading national and international manufac- turer of state-of-the-art uninterruptible power supplies, redundant switches, power management soft- ware, and related equipment. APC products protect hardware, software, and data from the threat of power disturbances in business and government offices throughout the world. The APC Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sags, and sur

Summary of the content on the page No. 4

anesthesia ventilators, infusion pumps, and any other device designated as “critical” by the U.S.F.D.A. Hospital grade wiring devices and leakage current may be ordered as options on many APC UPS systems, APC does not claim that units with this modification are certified or listed as Hospital Grade by APC or any other organization. Therefore these units do not meet the requirements for use in direct patient care. ELECTRICAL SAFETY  To reduce the risk of fire, connect only to a circuit

Summary of the content on the page No. 5

BATTERY SAFETY This equipment contains potentially hazardous voltages that may cause personal injury if handled incorrectly. This equipment must be installed and serviced only by qualified electrical service personnel.  This equipment contains potentially hazardous voltages. Do not attempt to disassemble the unit. The only exception is for equipment containing batteries. Battery replacement using the proce- dures below is permissible. Except for the battery, the unit contains no us

Summary of the content on the page No. 6

2: INSTALLATION The UPS has a “rack” design so it can be mounted in a 19-inch (46.5 cm) equipment rack. Hardware is provided. UNPACKING 1. Inspect the UPS upon receipt. APC designed robust packaging for your product. However, acci- dents and damage may occur during shipment. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly. 2. Check the package contents. The shipping package contains the UPS (with batteries discon

Summary of the content on the page No. 7

5. Connect the battery and attach the front bezel. 6. Connect the equipment and power to the UPS. 7. Turn on the UPS. INSTALLING THE MOUNTING RAILS IN THE RACK Install the mounting rails in the rack. Directions are included with the rail kit. The UPS comes with standard 19-inch (46.5 cm) rack mounting rails, brackets, and cleats. The rack can have any of the common types of equipment mounting holes (square, round-threaded, or round-non-threaded). All necessary hardware is provided. REM

Summary of the content on the page No. 8

3. Locate the battery module handle at the top of the battery face plate . 4. Be careful during this step—the battery module is heavy. Pull the battery module handle toward you to slide the battery module out of the UPS.  DO NOT pull on the battery cables or the white cord. MOUNTING THE UPS IN THE RACK Due to its weight, two people are required to install the UPS in the rack. 1. Supporting the UPS on both sides, carefully align the unit with the rails. Use the handles  on

Summary of the content on the page No. 9

CONNECTING THE BATTERY AND ATTACHING THE FRONT BEZEL 1. Facing the front of the UPS, locate the battery cables  and the UPS battery connector jack  to the right of the battery module. 2. To connect the battery connector plug  to the battery jack, push the plug into the jack so the metal pieces inside each part are touching. Press firmly to ensure a tight connection. You will hear  a “snap” when the connector is seated properly.   3. Push the battery cables and white cord as c

Summary of the content on the page No. 10

4. Turn on all connected equipment (loads). To use the UPS as a master ON/OFF switch, be sure all connected loads are switched on. The loads will not be powered until the UPS is turned on. 5. Add any optional accessories. See the documentation accompanying the accessory for details. TURNING ON THE UPS Make sure the battery is connected before turning on the UPS! Then, press the button on the front panel to power up your UPS. This will power up connected equipment. (Make sure connected l

Summary of the content on the page No. 11

3: OPERATION INDICATORS AND CONTROLS ON THE SMART-UPS The APC Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sags and surges from reaching your computer and other valuable electronic equipment. The UPS filters out small utility line fluctuations and isolates your equipment from large disturbances by internally dis- connecting from the utility line. The UPS provides continuous power from its internal batteries until the utility line returns to safe levels.

Summary of the content on the page No. 12

SELF-TEST The UPS performs a self-test automatically when turned on, and every two Automatic weeks thereafter (by default). Refer to the User Configuration Items for Self-Test details on changing the default interval. Automatic self-test eases maintenance requirements by eliminating the need for periodic manual self-tests. During the self-test, the UPS briefly operates the connected equipment on-battery. If the UPS passes the self- test, it returns to on-line operation. If the UPS fa

Summary of the content on the page No. 13

This LED illuminates to indicate the UPS is compensating for a high util- Voltage ity voltage. Trim This LED illuminates to indicate the UPS is compensating for a low utility Voltage voltage. Boost BATTERY POWER If the utility power fails, the UPS can provide power to the connected equipment from its internal battery for a finite period. The UPS sounds an alarm—four beeps every 30 seconds—while operating on-battery power. The alarm stops when the UPS returns to on-line operation.

Summary of the content on the page No. 14

SMART-UPS REAR PANEL The rear panel has the input and output connectors, computer interface port, and default setting but- tons for the low battery warning level and voltage sensitivity indicator. 120V Models 230V Models BASIC CONNECTORS Power management software and interface kits can be used with Computer the UPS. Use only interface kits supplied or approved by APC. Interface Port If used, connect the interface cable to the 9-pin computer interface port. Secure the connector

Summary of the content on the page No. 15

To reduce UPS sensitivity, press the voltage sensitivity button. Use a pointed object (such as a pen) to do so. Press the button once to set sensitivity to reduced. Press it again to set sensitivity to low. Press the button a third time to reset normal sensitivity. You also can change the sensitivity level through software. normal Brightly lit: UPS is set to normal sensitivity. reduced Dimly lit: UPS is set to reduced sensitivity. low Off: UPS is set to low sensitivity. The low b

Summary of the content on the page No. 16

ON-BATTERY OPERATION The Smart-UPS switches to battery operation automatically if the utility power fails. While running on-battery, an internal alarm sounds (periodic beeps). Press the button (front panel) to silence the UPS alarm (for the current alarm only). You can change the audible indicator if you are using the PowerChute software. If the utility power does not return, the UPS continues to supply power to the connected equipment until exhausted. The UPS will begin to beep continu

Summary of the content on the page No. 17

4: USER CONFIGURATION ITEMS NOTE: SETTING THESE ITEMS REQUIRES SOFTWARE OR OPTIONAL HARDWARE. FACTORY USER SELECTABLE FUNCTION DESCRIPTION DEFAULT CHOICES Automatic Self- Every 14 days Every 7 days This function sets the interval at which Test (336 hours) (168 hours), the UPS will execute a self-test. Refer On Startup Only, to your software manual for details. No Self-Test UPS ID UPS_IDEN Up to eight char- Use this field to uniquely identify the acters to define UPS for network man

Summary of the content on the page No. 18

NOTE: SETTING THESE ITEMS REQUIRES SOFTWARE OR OPTIONAL HARDWARE. FACTORY USER SELECTABLE FUNCTION DESCRIPTION DEFAULT CHOICES 120V Models 120V Models High Transfer To avoid unnecessary battery usage, set 132 VAC 138, 135, 129 VAC Point the high transfer point higher if the utility voltage is chronically high and 230V Models 230V Models the connected equipment is known to 253 VAC 264, 271, 280 VAC work under this condition. Low Transfer 120V Models 120V Models Set the low transf

Summary of the content on the page No. 19

5: STORAGE AND MAINTENANCE STORAGE STORAGE CONDITIONS Store the UPS covered and flat (rack mount orientation) in a cool, dry location, with its batteries fully charged. Disconnect any cables connected to the computer interface port to avoid unnecessary bat- tery drainage. EXTENDED STORAGE At -15 to +30 °C (+5 to +86 °F), charge the UPS battery every six months. At +30 to +45 °C (+86 to +113 °F), charge the UPS battery every three months. REPLACING THE BATTERY MODULE This UPS has an e

Summary of the content on the page No. 20

6: TRANSPORTING YOUR SMART-UPS REMOVING THE UPS FROM THE RACK Always DISCONNECT THE BATTERY before shipping the UPS to avoid damage during transport. (U.S. Federal Regulation requires that batteries are disconnected during shipment.) The battery may remain in the UPS; it does not have to be re- moved. This requirement applies whether the UPS is shipped alone or installed in an equipment rack or system. REMOVING THE FRONT BEZEL 1. Shut down any equipment attached to the UPS. 2. Disc


Alternative user manuals
# User manual Category Download
1 American Power Conversion 100 User manual Power Supply 0
2 American Power Conversion 120 User manual Power Supply 0
3 American Power Conversion 110, 120, 230 User manual Power Supply 0
4 American Power Conversion 10000 VA User manual Power Supply 1
5 American Power Conversion 1000, 1100, 1400 User manual Power Supply 2
6 American Power Conversion 110Vac User manual Power Supply 0
7 American Power Conversion 1400XLT User manual Power Supply 0
8 American Power Conversion 1050 User manual Power Supply 0
9 American Power Conversion 10-40kW 208/480V User manual Power Supply 0
10 American Power Conversion 2200 VA User manual Power Supply 0
11 American Power Conversion 2200XLT User manual Power Supply 0
12 American Power Conversion 208/220 User manual Power Supply 0
13 American Power Conversion 20000 VA User manual Power Supply 3
14 American Power Conversion 230 VAC User manual Power Supply 0
15 American Power Conversion 200-240 VAC User manual Power Supply 0
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2