Friedrich ZQ08 user manual

User manual for the device Friedrich ZQ08

Device: Friedrich ZQ08
Category: Air Conditioner
Manufacturer: Friedrich
Size: 4.63 MB
Added : 8/24/2014
Number of pages: 62
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Friedrich ZQ08. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Friedrich ZQ08.

For your convenience

If looking through the Friedrich ZQ08 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Friedrich ZQ08 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Friedrich ZQ08 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Friedrich ZQ08 User manual - Online PDF
Advertisement
« Page 1 of 62 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Friedrich ZQ08 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Friedrich ZQ08. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ENGLISH FRANÇAIS ESPAÑOL
1
Room Air Conditioner
Installation and Operation
Manual
CP Line
115 Volts CP08 ZQ08 ZQ10
Registering Your Room Air Conditioner
Model information can be found on the name plate located on the
side of the unit near the control panel. Please complete and mail
the owner registration card furnished with this product or register
on-line at www.friedrich.com (USA only). For your future
convenience, record the model information here.
MODEL NUMBER SERIAL NU

Summary of the content on the page No. 2

2

Summary of the content on the page No. 3

ENGLISH 3 Congratulations! You have purchased a Friedrich room air conditioner. The Friedrich units are designed to give maximum comfort and quietness. Table of Contents Introduction ..................................................................................2 Safety Precautions.......................................................................3 How to operate your Friedrich ...................................................5 How to operate your Friedrich ZStar ................

Summary of the content on the page No. 4

4 Introduction Before Operating Your Unit Make sure the wiring is adequate for your unit. If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in figure 1. DO NOT use an extension cord. The cord provided will carry the proper amount of electrical power to the unit; an extension cord will not. Make sure that the receptacle is compatible wi

Summary of the content on the page No. 5

ENGLISH 5 Safety Precautions To prevent injury and property damage, follow these instructions. Incorrect operation due to ignoring of instruction can cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION properties only. Meanings of symbols used in this manual are as shown below. Never Do This Always Do This WARNING Plug i

Summary of the content on the page No. 6

6 When the air filter is to be Do not clean the air When the unit is to be conditioner with water. cleaned, switch the unit off, removed, do not touch the and unplug it. metal parts of the unit. • They are sharp and may cause • Since the fan rotates at high • Water may enter the unit and an injury. degrade the insulation. It may speed during operation, it may cause an electric shock. cause an injury. Do not operate the unit Do not put a pet or house Do not use for special without the air filter

Summary of the content on the page No. 7

ENGLISH 7 How to operate your Friedrich 2 6 Power 1 Temp 2 Fan Speed 4 Timer Mode 5 3 3 5 4 1 Control and Remote Control Operations 1. POWER 4. FAN SPEED SELECTOR Operation begins when this button is pressed For increased power while cooling, select a and stops when you press the button again. higher fan speed. 2. TEMPERATURE CONTROL 3 steps: High; Low; Med The thermostat monitors room temperature 5. ON/OFF TIMER to maintain the desired temperature. The timer can be set to start and stop the Th

Summary of the content on the page No. 8

8 ® How to operate your Friedrich ZStar Function Controls MED MED HIGH HIGH Off - Turns air conditioner off. F FAN AN COOL COOL Med Fan - Med speed fan operation without cooling. Low Fan - Low speed fan operation without cooling. High Cool - Cooling with high speed fan operation. LOW LOW MED MED F FAN AN COOL COOL Med Cool - Cooling with med speed fan operation. LOW COOL LOW COOL Low Cool - Cooling with low speed fan operation. 5 5 4 4 6 6 This automatically controls the temperature of the indoo

Summary of the content on the page No. 9

ENGLISH 9 Adjusting the Air Flow Direction Vent Control For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation. OPEN the vent to discharge stale air. Part A CLOSE VENT OPEN NOTE : Before using the ventilation feature, position the vent lever by pulling Part A out straight and snapping it into place. Adjusting the Air Flow Direction Airflow can be adjusted by changing the direction of the air conditioner's louvers. • Adjusting Horizontal Air Flow Direction • Ad

Summary of the content on the page No. 10

10 Care and Maintenance Turn the power off and unplug the power plug before cleaning the air conditioner. Air Filter The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner. How to remove the air filter 1. The grille may be opened from the top for easy maintenance after installation. 2. Open the inlet grille by pulling out on the exposed door on the top of the unit (based on install

Summary of the content on the page No. 11

ENGLISH 11 Hardware Location Product Features CAUTION This appliance should be installed in accordance with local and national wiring regulations. This manual acts as a guide to help to explain product features. 13 6 7 11 5 8 14 9 1 12 2 4 15 10 3 1. CABINET 8. HORIZONTAL AIR DEFLECTOR 2. FRONT GRILLE (VERTICAL LOUVER) 3. AIR FILTER 9. CONTROL PANEL 4. AIR INTAKE (INLET GRILLE) 10. POWER CORD 5. AIR DISCHARGE 11. COMPRESSOR 6. VERTICAL AIR DEFLECTOR 12. BASE PAN (HORIZONTAL LOUVER) 13. BRACE 7.

Summary of the content on the page No. 12

12 How to Install the Unit 1. To prevent vibration and excess noise, Fence make sure the unit is installed securely Awning and firmly Cooled air 2. Install the unit where the sunlight does not Heat shine directly on the unit. radiation 3. The outside of the cabinet must extend outward for at least 12" and there should be no obstacles, such as a fence or wall, 1 About /2" within 20" from the back of the cabinet, as Over 20" it will prevent heat radiation of the condenser. Restriction of outside

Summary of the content on the page No. 13

ENGLISH Installation Kit Contents NO. NAME OF PARTS Q'TY 2 3 4 1 1 FRAME CURTAIN 2 2 SILL SUPPORT 2 3 BOLT 2 4 NUT 2 5 6 7 8 13 5 SCREW (TYPE A) 16 6 SCREW (TYPE B) 3 7 SCREW (TYPE C) 5 10 8 FOAM-STRIP 1 12 9 UPPER GUIDE 1 9 10 FOAM-PE 1 11 11 FRAME GUIDE 2 12 WINDOW LOCKING BRACKET 1 13 FOAM-PE 1 Suggested Tool Requirements SCREWDRIVER(+, -), RULER, KNIFE, HAMMER, PENCIL, LEVEL Shipping PREPARATION OF CHASSIS Screws 1. Remove the screws which fasten the cabinet at both sides and at the back.(4

Summary of the content on the page No. 14

14 Cabinet Installation 1. Open the window. Mark a line on center of the window stool. Carefully place the cabinet on the window stool and align the center mark on the bottom front with the center line marked in the Upper Guide window stool. Window stool Front Angle Fig. 1 2. Pull the bottom window sash down behind the Upper Guide until they meets. Window Sash Upper guide NOTE: Do not pull the window sash down so 13 Foam-pe tightly that the movement of Frame Curtain is restricted. Cabinet 1 Fram

Summary of the content on the page No. 15

ENGLISH 15 6. The cabinet should be installed with a very slight tilt (about 1/2") downward toward the outside 6 Screw(Type B) (See Fig. 5). Adjust the bolt and the nut of Sill Support for balancing the cabinet. Sill Support 2 7. Attach the cabinet to the window stool by driving Sash track the screws [Type B: Length 16mm (5/8 inch) and below.] through the front angle into window stool. 8. Pull each Frame Curtain to each window sash track, and repeat step 2. Front Angle 6 Screw(Type B) 2 Sill Su

Summary of the content on the page No. 16

16 12. Attach the Window Locking Bracket with a Type C Window locking screw . (See Fig. 9) 12 bracket Fig. 9 13. Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet. Push the grille in until it snaps into place. (See Fig. 10) Fig. 10 14. Pull down the inlet grille and secure it with a Type A screw through the front grille. (See Fig. 11) 15. Window installation of room air conditioner is now completed. See ELECTRICAL DATA for inse

Summary of the content on the page No. 17

ENGLISH 17 Installation Instructions Read these instructions completely and carefully. Tools You Will Need Phillips-head screwdriver Scissors or knife Flat-blade screwdriver Pencil Ruler or tape measure Level Hammer Before You Begin NOTE TO INSTALLER: Leave these CAUTION: instructions with the air conditioner after Do not under any circumstances, cut or remove installation is completed. the third (ground) prong from the power cord. Do not change the plug on the power cord of NOTE TO CONSUMER: Ke

Summary of the content on the page No. 18

18 Electr Electrical Saf ical Safety ety Electrical Saf Electrical Safety ety Electrical Data Electrical Data 115V~ 115V~ P Po ow wer cord ma er cord may include a current y include a current interr interrupter de upter device vice.. A test and reset b A test and reset button is utton is pro provided on the plug case vided on the plug case.. The de The device vice should be tested on a per should be tested on a periodic basis b iodic basis by first y first pressing the pressing the TEST

Summary of the content on the page No. 19

ENGLISH 19 Troubleshooting Tips Troubleshooting Tips save time and money! Review the chart below first and you may not need to call for service. Normal Operation You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. You may hear the thermostat click when the compressor cycles on and off. Water will collect in the base pan during high humidity

Summary of the content on the page No. 20

20 FRIEDRICH AIR CONDITIONING CO. Post Office Box 1540 • San Antonio, Texas 78295-1540 (210) 357-4400 • FAX (210) 357-4490 ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units a


Alternative user manuals
# User manual Category Download
1 Friedrich 000 BTU'S User manual Air Conditioner 23
2 Friedrich 115 Volts US10 User manual Air Conditioner 23
3 Friedrich 18 User manual Air Conditioner 11
4 Friedrich 115 Volts UE08 User manual Air Conditioner 7
5 Friedrich 2003 User manual Air Conditioner 6
6 Friedrich 115 Volts US12 User manual Air Conditioner 12
7 Friedrich 2006 User manual Air Conditioner 5
8 Friedrich 1883 User manual Air Conditioner 8
9 Friedrich 000 BTU/h User manual Air Conditioner 1
10 Friedrich 115 Volts US08 User manual Air Conditioner 2
11 Friedrich 2007 User manual Air Conditioner 2
12 Friedrich 2008 User manual Air Conditioner 2
13 Friedrich 230 Volts US10 User manual Air Conditioner 7
14 Friedrich 2009 User manual Air Conditioner 3
15 Friedrich 24 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21