Friedrich WY13B33A-B user manual

User manual for the device Friedrich WY13B33A-B

Device: Friedrich WY13B33A-B
Category: Air Conditioner
Manufacturer: Friedrich
Size: 0.87 MB
Added : 8/24/2014
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Friedrich WY13B33A-B. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Friedrich WY13B33A-B.

For your convenience

If looking through the Friedrich WY13B33A-B user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Friedrich WY13B33A-B on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Friedrich WY13B33A-B to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Friedrich WY13B33A-B User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Friedrich WY13B33A-B but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Friedrich WY13B33A-B. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Service & Parts Manual
®
WS08B10A-C
WallMaster Thru-the-Wall
WS10B10A-C
WS14B10A-C
WS10B30A-C
WS13B30B-C
WS16B30A-C
WE10B33A-B
WE13B33B-B
WE16B33A-B
WY10B33A-B
WY13B33A-B
WM-Svc-Prts-07 (3-07)
PM
72
Power
Cool
Fan ®
Speed Mode Money Saver
Fan Only
Clock
Timer SStar et t Time
On/Off Hour
Stop Time Temp/Hour

Summary of the content on the page No. 2

TABLE OF CONTENTS Warranty .....................................................................................................................................................3 Routine Maintenance ................................................................................................................................4 Unit Identifi cation ......................................................................................................................................5 Performance Da

Summary of the content on the page No. 3

Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com WALLMASTER THRU-THE-WALL AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible un

Summary of the content on the page No. 4

ROUTINE MAINTENANCE NOTE: Units are to be inspected and serviced by qualifi ed service personnel only. Routine maintenance is required annually or semi-annually, depending upon annual usage. 1. Clean the unit air intake fi lter at least every 250 to 300 fan hours of operation or when the unit’s indicator light is on if so equipped. Clean the fi lters with a mild detergent in warm water and allow to dry thoroughly before reinstalling. 2. The indoor coil (evaporator coil), the outdoor coil (conden

Summary of the content on the page No. 5

FRIEDRICH ROOM MODEL NUMBER CODE W S 08 B 1 0 B 1st DIGIT - FUNCTION W = Thru-The-Wall, WallMaster Series 2nd DIGIT - TYPE S = Straight Cool E = Electric Heat Y = Heat Pump 3rd & 4th DIGITS - APPROXIMATE BTU/HR (Cooling) Heating BTU/HR capacity listed in Specifi cations/Performance Data Section 5th DIGIT - ALPHABETICAL MODIFIER 6th DIGIT - VOLTAGE 1 = 115 Volts 3 = 230-208 Volts 7th DIGIT 0 = Straight Cool & Heat Pump Models ELECTRIC HEAT MODELS 3 = 3 KW Heat Strip, Nominal 8th D

Summary of the content on the page No. 6

PERFORMANCE DATA * Rating Conditions: 80 degrees F, room air temp. & 50% relative humidity, with 95 degree F, outside air temp & 40% relative humidity Calculate the heat loss of the space to be heated. As long as the heat loss does not exceed the resistance heating capacity rating of the unit, the heating performance will be satisfactory. Change-over from heat pump operation to resistance operation on models indicated is automatic at a preset outside ambient temperature of approximately 35°F

Summary of the content on the page No. 7

ELECTRICAL DATA Wire Size Use ONLY wiring size recommended for single outlet branch circuit. Fuse/Circuit Use ONLY type and size fuse or HACR Breaker circuit breaker indicated on unit’s rating plate. Proper current protection to the unit ELECTRIC SHOCK HAZARD. is the responsibility of the owner. Turn off electric power before service or installation. Grounding Unit MUST be grounded from branch All electrical connections and wiring MUST be circuit through service cord to unit, or installe

Summary of the content on the page No. 8

FUNCTIONAL COMPONENTS A. Mechanical components Bellows condensate valve Temperature-sensitive valve that opens up to drain off condensate water when the outside temperature falls below 40°F and closes when the outside temperature reaches 58°F. Plenum assembly Diffuser with directional louvers used to direct the conditioned airfl ow. Blower wheel Attaches to the indoor side of the fan motor shaft and is used for distributing unconditioned, room side air though the heat exchanger and delivering c

Summary of the content on the page No. 9

SYSTEM CONTROL PANEL (“WS” Models) Activating Error Code Mode (Submode of Test Mode) Figure 6: System Control Panel Unit must be in Test Mode to enter Error Code Mode 1. Activate Error Code Mode by pressing the “TIMER ON/OFF” button on XQ & WS models. LED for the “TIMER ON/OFF” will fl ash 1bps while Error Code PM Mode is active. Pressing the “TEMP/HR + ” button will display 00. Consecutive presses will scroll through all 72 Power error codes logged. Press the “TEMP/HR - ” button to

Summary of the content on the page No. 10

Frost Probe Sensor: Disables compressor at 35 degrees SYSTEM CONTROL SWITCH - TEST F +/- 3 degrees F Disconnect leads from control switch. Turn control to posi- tion being tested (see Figure 8). There must be continuity Indoor Probe Sensor: Control range is 60 degrees F to 90 as follows: degrees F +/- 2 degrees F Indoor temperature will be displayed by pressing: 1. “Off” Position-no continuity between terminals. (XQ / WS Units) The Fan Speed button and the Temp Up 2. “Lo Cool” Position-betwee

Summary of the content on the page No. 11

REFRIGERATION SYSTEM SEQUENCE OF OPERATION A good understanding of the basic operation of the refrigera- the evaporator coil. As it enters the evaporator coil, the tion system is essential for the service technician. Without larger area and lower pressure allows the refrigerant to this understanding, accurate troubleshooting of refrigeration expand and lower its temperature (heat intensity). This system problems will be more diffi cult and time consuming, expansion is often referred to as “boi

Summary of the content on the page No. 12

HERMETIC COMPONENT REPLACEMENT SEALED REFRIGERATION SYSTEM The following procedure applies when replacing com- REPAIRS ponents in the sealed refrigeration circuit or repairing EQUIPMENT REQUIRED: refrigerant leaks. (Compressor, condenser, evaporator, capillary tube, refrigerant leaks, etc.) 1. Voltmeter 1. Recover the refrigerant from the system at the pro- 2. Ammeter cess tube located on the high side of the system by 3. Ohmmeter installing a line tap on the process tube. Apply gauge

Summary of the content on the page No. 13

10. Evacuate system to maximum absolute holding pres- ROTARY COMPRESSOR SPECIAL sure of 200 microns or less. NOTE: This process can TROUBLESHOOTING AND SERVICE be speeded up by use of heat lamps, or by breaking Basically, troubleshooting and servicing rotary compres- the vacuum with refrigerant or dry nitrogen at 5,000 sors is the same as on the reciprocating compressor with microns. Pressure system to 5 PSIG and leave in only a few exceptions. system a minimum of 10 minutes. Release refr

Summary of the content on the page No. 14

TROUBLESHOOTING TOUCH TEST CHART: TO SERVICE REVERSING VALVES NORMAL FUNCTION OF VALVE NOTES: VALVE OPERATING * TEMPERATURE OF VALVE BODY CONDITION ** WARMER THAN VALVE BODY 1 2 3 4 5 6 POSSIBLE CAUSES CORRECTIONS Cool Hot Hot Cool *TVB TVB Normal Cooling as (2) as (1) Hot Cool Hot Cool *TVB TVB Normal Heating as (1) as (2) MALFUNCTION OF VALVE No voltage to coil. Repair electrical circuit. Check Electrical circuit and coil Defective coil. Replace coil. Low charge. Repair leak, recharge sys

Summary of the content on the page No. 15

COOLING ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS Problem Possible Cause Action Check voltage at compressor. 115V & 230V Low voltage units will operate at 10% voltage variance T-stat not set cold enough or Set t-stat to coldest position. Test t-stat & re- inoperative place if inoperative Compressor hums but cuts off on Hard start compressor. Direct test compressor. B10 overload If compressor starts, add starting components Compressor Open or shorted compressor does not run Check for c

Summary of the content on the page No. 16

Problem Possible Cause Action Replace fuse, reset breaker. If repeats, check Fuse blown or circuit tripped fuse or breaker size. Check for shorts in unit wiring & components Power cord not plugged in Plug it in Unit does not run System switch in "OFF" position Set switch correctly Inoperative system switch Test for continuity in each switch position Loose or disconnected wiring at Check wiring & connections. Reconnect per switch or other components wiring diagram Problem Possible Cause Actio

Summary of the content on the page No. 17

Problem Possible Cause Action Overload inoperative. Opens too Check operation of unit. Replace overload if soon system operation is satisfactory Allow a minimum of 2 minutes to allow Compressor restarted before pressures to equalize before attempting to system pressures equalized restart. Instruct customer of waiting period Check voltage with unit operating. Check for other appliances on circuit. Air conditioner Compressor runs Low or fl uctuating voltage should be in separate circuit for

Summary of the content on the page No. 18

Problem Possible Cause Action Sublimation: Ensure that foam gaskets are installed in When unconditioned saturated, between window panes & in between the outside air mixes with conditioned unit & the sleeve. Also, ensure that fresh air, condensation forms on the air/exhaust vents (on applicable models) are in cooler surfaces the closed position & are in tact Water "spitting" into room Follow installation instructions to ensure that Downward pitch of install

Summary of the content on the page No. 19

HEAT / COOL ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS Problem Possible Cause Action Disconnect power to unit. Remove resistor Heat anticipator (resistor) shorted from t-stat bulb block. Plus in unit & allow to (on applicable models) operate. Feel resistor for heat. If not heat, replace resistor Room temperature uneven Wide differential - partial loss of Replace t-stat & check (Heating cycle) t-stat bulb charge Refer to appropriate wiring diagram. Resistor Incorrect wiring is energized du

Summary of the content on the page No. 20

Problem Possible Cause Action Incorrect wiring Refer to applicable wiring diagram Defective solenoid coil Check for continuity of coil Block condenser coil & switch unit to cooling. Unit cools when Allow pressure to build up in system, then heat is called for Reversing valve fails to shift switch to heating. If valve fails to shift, replace valve. Inoperative system switch Check for continuity of system switch Problem Possible Cause Action Heating capillary tube partially Check for partially


Alternative user manuals
# User manual Category Download
1 Friedrich 000 BTU'S User manual Air Conditioner 23
2 Friedrich 115 Volts US10 User manual Air Conditioner 23
3 Friedrich 18 User manual Air Conditioner 11
4 Friedrich 115 Volts UE08 User manual Air Conditioner 7
5 Friedrich 2003 User manual Air Conditioner 6
6 Friedrich 115 Volts US12 User manual Air Conditioner 12
7 Friedrich 2006 User manual Air Conditioner 5
8 Friedrich 1883 User manual Air Conditioner 8
9 Friedrich 000 BTU/h User manual Air Conditioner 1
10 Friedrich 115 Volts US08 User manual Air Conditioner 2
11 Friedrich 2007 User manual Air Conditioner 2
12 Friedrich 2008 User manual Air Conditioner 2
13 Friedrich 230 Volts US10 User manual Air Conditioner 7
14 Friedrich 2009 User manual Air Conditioner 3
15 Friedrich 24 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21