Friedrich WallMaster PTAC user manual

User manual for the device Friedrich WallMaster PTAC

Device: Friedrich WallMaster PTAC
Category: Air Conditioner
Manufacturer: Friedrich
Size: 0.78 MB
Added : 3/28/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Friedrich WallMaster PTAC. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Friedrich WallMaster PTAC.

For your convenience

If looking through the Friedrich WallMaster PTAC user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Friedrich WallMaster PTAC on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Friedrich WallMaster PTAC to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Friedrich WallMaster PTAC User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Friedrich WallMaster PTAC but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Friedrich WallMaster PTAC. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
WallMaster PTAC
Packaged Terminal Air Conditioners & Heat Pumps
• Standard
• Remote Thermostat
• Seacoast Protected
Installation & Operation Manual
920-087-02 (9-03)

Summary of the content on the page No. 2

920-087-02 (9-03) 920-087-02 (9-03) Table of Contents Unit Components .........................................................................................................................................................................................2 P-Series Announcement/Model Number Code............................................................................................................................................3 Installation Recommendations .................................

Summary of the content on the page No. 3

920-087-02 (9-03) 920-087-02 (9-03) Announcing the Friedrich P-Series Packaged Terminal Air Conditioner. A new approach to reliability and efficiency. A totally redesigned Friedrich PTAC. Thank you for your decision to purchase the newly designed Friedrich Packaged Terminal Air Conditioner (PTAC). We are confident that you will find this unit a quiet and efficient example of Friedrich reliability. This Installation and Operation Manual has been designed to insure maximum satisfaction in the p

Summary of the content on the page No. 4

920-087-02 (9-03) 920-087-02 (9-03) PTAC Installation Recommendations For proper PTAC unit performance and maximum operating life please refer to the minimum installation clearances below: Figure 1 PTAC units should be installed no closer than 12" apart when THREE OR MORE PTACs two units are side by side. If ADJACENT 36" MINIMUM VIEW: OUTSIDE three of more PTAC units are to BUILDING ELEVATION operate next to one another allow TYP. WINDOW a minimum of 36" between units. Also, a vertical cle

Summary of the content on the page No. 5

920-087-02 (9-03) 920-087-02 (9-03) Installation Instructions PXDR10 Drain Kit NOTE: Determine whether drain will be located within the wall, on the indoor side, or will drain to the exterior of the building. Follow appropriate instructions below depending on your particular type of installation. Internal Drain (optional for new construction) NOTE: If installing an internal drain, you MUST install a drain kit on the wall sleeve before the wall sleeve is installed. Figure 3 1. Refer to

Summary of the content on the page No. 6

920-087-02 (9-03) 920-087-02 (9-03) External Drain (for new construction or unit replacement) When using an external drain system, the condensate is removed through either of two drain holes on the back of the wall sleeve. Select the drain hole which best meets your drainage situation and install the drain kit. Seal off the other with a cover plate. Drain Tube Installation Cover Plate Installation 1. Peel the backing tape off the gaskets and apply the sticky 4. Mount the fo

Summary of the content on the page No. 7

133⁄4 " (34.9 cm) 10" (25.4 cm) max. 920-087-02 (9-03) 920-087-02 (9-03) Wall Sleeve Installation Instructions (PXWS) NOTE: Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve, chassis and accessories. If the sleeve projects more than 8" into the room, a subbase or other means of support MUST be used. Please read these instructions completely before attempting installation. Figure 5 Typical Wall Sleeve Installation 161⁄4 "

Summary of the content on the page No. 8

920-087-02 (9-03) 920-087-02 (9-03) Figure 6 A B Dimensions Dimension* Allow Allow for floor finishing 1⁄4" A (6.4 cm) for wall min. finishing (Minimum) Min. Max No Accessories 1⁄4" 1⁄4" (6.4 mm)* (6.4 mm) --- With Subbase 13⁄4" 31⁄2" 5" (4.5 cm) (8.9cm) (12.7cm) 133⁄4 " (35 cm) With Lateral Duct 3⁄4" 1⁄4" (1.9 cm) (6.4 mm) --- B Wall * If more than one accessory is to be used, use the maximum dimension. If the wall thickness is more than 133⁄4" (35cm) - (A + 1⁄4" [6.4 mm]), a sleeve extens

Summary of the content on the page No. 9

920-087-02 (9-03) 920-087-02 (9-03) Section II — Deep Wall Installation (PXWE) If the wall is thicker than allowed in the notes in Figure 6, a sheet 6. Condensate notches and overflow slots must be kept clear metal wall sleeve extension and flashing MUST be used. of sealant and gaskets so condensate can flow freely into the wall sleeve extension. Installation Instructions for the PXWE – 4" Wall Sleeve NOTE: Improper fabrication or installation of a wall sleeve extension Extension will

Summary of the content on the page No. 10

920-087-02 (9-03) 920-087-02 (9-03) Installation Instructions Model PXGA Standard Grille 1. Remove the center support and weatherboard if still installed 5. Grasp the grille by the attached plastic handles. Position it with in the sleeve. the condensate drain knockouts facing down. From inside the building, maneuver the grille through the wall sleeve and pull 2. Insert six plastic grommets into the grille openings from the toward you until the screw heads are inserted into the keyhole

Summary of the content on the page No. 11

920-087-02 (9-03) 920-087-02 (9-03) A. Installation Checklist Inspect all components and accessories for damage Install the recommended Condensate Drain Kits for o o before and after installation. complete condensate removal. Remove the cardboard wall sleeve support and grille Ensure that the chassis is installed in a 16" high x 42" wide o o weatherboard. wall sleeve that is no deeper than 13 3/4". A baffle kit is required if the sleeve exceeds that depth. Check for proper wall sleeve ins

Summary of the content on the page No. 12

920-087-02 (9-03) 920-087-02 (9-03) Section III – Chassis Installation * Check to be sure the wall sleeve, extension (if used), grille, and drain kit are installed properly before chassis installation 1. Remove the weatherboard and center support from NOTE: To avoid breaking the door or hinge pins, do not apply the sleeve (if still in place). Be sure an outdoor grille is excessive force when installing attached. Pins 2 1 Wall sleeve Control Door Weatherboard Front Panel Center support 3.

Summary of the content on the page No. 13

920-087-02 (9-03) 920-087-02 (9-03) 4. Center the chassis in the pre-installed sleeve and carefully at the bottom back corners of the cover. Tighten them into push the chassis until the chassis flange and gasket contact the quick nuts located on the chassis to secure the cover. If the sleeve flange. the unit has been placed such that there is no room to insert the thumbscrews from the bottom, request a Side Mounting kit (Part No. PXSM) from Friedrich. Locate the service cord or conduit

Summary of the content on the page No. 14

920-087-02 (9-03) 920-087-02 (9-03) C. Standard Unit Operation Rotate the temperature dial in small increments in the Rotary Switch Operation warmer or cooler direction. Moving the dial more than 1/4" at a time may overcompensate and result in an Control Operation extreme hot or cold situation. The full-range thermostat maintains room temperature at the desired setting in both • If a remote thermostat is installed, see Appendix A, the heating and cooling modes. Turn the dial page 18-20.

Summary of the content on the page No. 15

920-087-02 (9-03) 920-087-02 (9-03) E. Heating Control (heat pumps and emergency heat operation) NOTE: Heat pump models only. Heat pump equipped models use backup electric resistance heating coils. At extremely low, outdoor ambient temperatures, the heat pump is automatically disabled and the unit operates solely on electric resistance heat. This control is located behind the decorative front cover and is found on the right side panel of the chassis. Its function is to allow you to set

Summary of the content on the page No. 16

920-087-02 (9-03) 920-087-02 (9-03) H. Air Discharge Grille Moving parts hazard. Turn off electric power before servicing this component. Failure to do so can result in property damage, personal injury and/or death. The air discharge grille can be redirected to blow air either straight up or at an angle into the room. To change the airflow direction, remove the front cover, locate and remove the six grill retaining screws. Reverse the ends of the grille and refasten the grille to the cover.

Summary of the content on the page No. 17

920-087-02 (9-03) 920-087-02 (9-03) Appendix A: Remote Thermostat Unit Installation Remote Thermostat Selection & Wiring Guidelines for Manual Changeover Thermostat Packaged Terminal Air Conditioners For Heat Pump equipped units: A single stage, heat/cool thermostat with a terminal for a reversing valve operation is required. Follow the instructions and recommendations of the thermostat Terminal "B" should be continuously energized in the heat mode manufacturer for installation and wiring.

Summary of the content on the page No. 18

Remote Contr Remote Control Unit ol Unit OFF ON 920-087-02 (9-03) 920-087-02 (9-03) Appendix A (continued) Remote Thermostat 208V Operation Auto Changeover Thermostat A single stage heat/cool thermostat with auto changeover is needed. Connection Diagram The wiring scheme is the same as the manual thermostat. 208V 60HZ L2 L1 Remote Thermostat Installation Follow Steps 1 through 5 (pages 12 and 13), then: SMOOTH RIBBED G 6. Locate the terminal strip on the front of the control box (See Figure

Summary of the content on the page No. 19

920-087-02 (9-03) 920-087-02 (9-03) Appendix B: Electrical Wiring for 265 Volt Models NOTE: It is recommended that the PXSB subbase assembly, the PXCJ conduit kit and the PXDS disconnect switch be installed on all hardwired units. If installing a flush-floor mounted unit, make provisions for all the line voltage power leads and conduit to be removed for ease of maintenance and service to the chassis. To install the line voltage power leads and conduit to the chassis, follow the instructions

Summary of the content on the page No. 20

920-087-02 (9-03) 920-087-02 (9-03) J. Routine Maintenance NOTE: Units are to be inspected and serviced by qualified service personnel only. 1. Clean the unit air intake filter at least every 300 to 350 hours compressed air or vacuum. If using a pressure washer, be of operation. Clean the filters with a mild detergent in warm careful not to bend the aluminium fin pack. Use a sweeping water and allow to dry thoroughly before reinstalling. up and down motion in the direction of the vertical


Alternative user manuals
# User manual Category Download
1 Friedrich 000 BTU'S User manual Air Conditioner 23
2 Friedrich 115 Volts US10 User manual Air Conditioner 23
3 Friedrich 18 User manual Air Conditioner 11
4 Friedrich 115 Volts UE08 User manual Air Conditioner 7
5 Friedrich 2003 User manual Air Conditioner 6
6 Friedrich 115 Volts US12 User manual Air Conditioner 12
7 Friedrich 2006 User manual Air Conditioner 5
8 Friedrich 1883 User manual Air Conditioner 8
9 Friedrich 000 BTU/h User manual Air Conditioner 1
10 Friedrich 115 Volts US08 User manual Air Conditioner 2
11 Friedrich 2007 User manual Air Conditioner 2
12 Friedrich 2008 User manual Air Conditioner 2
13 Friedrich 230 Volts US10 User manual Air Conditioner 7
14 Friedrich 2009 User manual Air Conditioner 3
15 Friedrich 24 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21