Copyright 2001-2003 Airfree Produtos Eletrónicos Lda. All Rights Reserved All rights reserved. No part of this publication may be reproduced, photocopied, transmitted, transcribed, stored in a retrieval system, or translated into any lan- guage in any form or by any means without the express prior written consent of Airfree Produtos Eletrónicos Lda.
Summary of the content on the page No. 3
Index 3 Introduction Applications 4 7 Airfree and Mould 8 Technical Characteristics Airfree Description 9 Installing and Connecting 10 12 Safety Instructions How does Airfree work? Maintenance 13 14 Airfree’s Independent and Effi ciency Tests FAQ - Frequently Asked Questions 15 19 Warranty 1
Summary of the content on the page No. 4
Congratulations for having purchased your Airfree. Airfree air purifi ers are manufactured under license of US Patent 5,874,050, and many other patents pending worldwide. Airfree was designed with most advanced American and German technologies, to drastically destroy indoor airborne micro- organisms and reduce ozone. Different from other air purifi er manufacturers, Airfree does not spend much time in describing fancy technologies with diffi cult words and theories. Airfree offers independ
Summary of the content on the page No. 5
The Invisible Enemies Most people spend around 90% of their time indoors, at home or in the offi ce. The EPA – Environmental Protection Agency claims the quality of air indoors can be 100 times worse than outdoors. Some factors contribute to indoor contamination: - High concentration of people in rooms increase fungus, bacteria and vi- rus development, and cross contamination - New building insulation techniques reduce outside air interchanges and consequently air conditioning running cost,
Summary of the content on the page No. 6
Applications Healthy rooms with pure clean air The effi cient and noiseless Airfree technology safely destroys mould spores, bacteria, viruses and other airborne organic microorganisms. Respiratory allergies and Asthma Airfree drastically reduces airborne organic allergens and ozone, provid- ing cleaner and safer environment for allergic people. Airfree destroys mould spores, bacteria, viruses, dust mite allergens, pet dander and re- duces ozone, all kept to minimum levels. Children and Newbor
Summary of the content on the page No. 7
Applications Offi ces, Public Buildings Populated rooms, corridors, and elevators offer a constant contamination risk to employees and guests. This situation is aggravated by the fl ow of hazardous fungi and other microbes entering through the A/C system, and the ozone generated by computers and photocopiers. The spread of air- borne transmittable diseases can accelerate in this environment. Airfree is a powerful weapon in the reduction of airborne contamination by viruses, bacteria, fungi, a
Summary of the content on the page No. 8
Applications Pollens Pollens are no exception and like other microorganims are totally destroyed when passing through Airfree patented sterilising core. After being incinerated the resulting harmless particles are released back to the environment. Ozone (O3) Ozone is a very toxic gas that according to EPA can damage lung tissue, cause chest pain, throat irritation and trigger asthma. The FDA, the US Food and Drug Administration, recommends not to use any equipment directly or indirectly ge
Summary of the content on the page No. 9
Airfree and Mould Guide for Airfree installation in mould contaminated rooms 1 - Install your Airfree unit in accordance with the user manual 2 - Allow your unit to run for at least one week to achieve signifi cant airborne mould spore reduction. 3 - Clean mould infected items and surfaces, since they are a con- tinuous source of new spores. It is important to stress that Airfree will not destroy or remove mould from an infected item or surface. Those surfaces must be cleaned manually. Airfr
Summary of the content on the page No. 10
Technical Characteristics Model E60 Capacity 2119 cu.ft (60m³) Inside Temperature 392°F (200°C) Electric 45W Consumption Voltage 220V - 240V Noise Totally Silent Weight 2.4 lbs (1,09 Kg) height: 10.4in (26.5 cm) Dimensions diameter: 8.4in (21.5 cm) 8
Summary of the content on the page No. 11
Airfree Description 1 1- Top Lid with Air outlets 2- Side Shells 2 3- On/Off Led 3 4 4- Base 5- Air Inlets 6- Power Cord 5 6 9
Summary of the content on the page No. 12
Installing and Connecting Plug power cord to the nearest outlet. Make sure the surface is dry (never place Airfree on wet fl oor or immerge in water) Make sure side blue led is on. Place Airfree on the fl oor. Do not install it under furniture or shelves, behind curtains as it will reduce air fl ow and Airfree effi ciency in reducing microorganisms. Place each Airfree in rooms up to 258 sq. ft. (24m²) for E60. For larger rooms use proportionally additional Airfree units. The use of just one A
Summary of the content on the page No. 13
Installing and Connecting Airfree can only be used in rooms with minimum air volume of 330 cu. ft. (10 m3), free of obstacles. Airfree can be installed in rooms equipped with air conditioning and heating systems. However it is recommended not to place Airfree nearby them to avoid potential interference in Airfree air fl ow. Do not place Airfree in the corridor to try to reach the whole house. In this case Airfree will only reduce air pollution in the corridor area. Airfree is designed for i
Summary of the content on the page No. 14
Safety Instructions Before plugging in Airfree slightly shake it to check for any loose parts in its interior caused by unusual transportation event. If loose parts are noticed, please return the unit to the retailer. Do not place your Airfree in direct contact with water and liquids which may pose electric shock hazard and damage to the unit itself. Do not obstruct Airfree air outlets with items such as towels, clothing, curtains, as they can cause overheating and irreparable damage to the
Summary of the content on the page No. 15
How does Airfree Work? Maintenance Purifi ed Air Cooling Chamber Cold and clean air is delivered to the environment without signifi cant change in room temperature and humidity. Thermodynamic Sterilising System (TSS) Inside the ceramic core 99.99% of all microorganims are incinerated and eliminated from the environment Air Inlets Contaminated air enters Airfree by air convection Contaminated Air How Airfree works? Contaminated air silently enters Airfree by air convection an
Summary of the content on the page No. 16
® Airfree Independent and Airfree Independent and Effi ciency Tests Effi ciency Tests AIRFREE TECHNOLOGY USED IN THE AIRFREE E60 AIR STERLISERS EFFICIENCY TESTS BY INDEPENDENT LABORATORIES, INSTITUTES AND UNIVERSITIES IN FOLLOWING COUNTRIES. GERMANY - SWEEDEN - SPAIN - PORTUGAL - ITALY - USA - BRAZIL- KOREA Reduction of Microorganisms Laboratory Local Dust Mite allergens Fungus Bacteria DerP-1 Insect R&D Limited 70,6% to 97,95% Laboratory june, 2005 SGS Natec Institute* Hambur/Germany La
Summary of the content on the page No. 17
FAQ - Frequently Asked Questions 1. How does Airfree work? Airfree incinerates microorganisms at its heated capillaries. Contaminated air is dragged into Airfree’s ceramic core by air convection and microorganisms are destroyed at high temperatures regardless of how resistant and dangerous they might be. 2. Are there any side effects? No. Airfree’s new technology uses heat to purify the air. No side effects, no emis- sions, NO IONS, nor new particles are generated. Airfree should be used i
Summary of the content on the page No. 18
FAQ - Frequently Asked Questions 9. Is it necessary to keep doors and windows closed? It is preferable. But opening window for 1 or 2 hours a day will not affect Airfree effi ciency. 10. Does Airfree eliminate bacteria and viruses? Yes. Unlike the air fi lters in the market Airfree is more effi cient with the smallest microorganisms as they are easily carried by Airfree’s airfl ow into its heated ce- ramic core. 11. Can I change Airfree from one room to another? Airfree must always
Summary of the content on the page No. 19
FAQ - Frequently Asked Questions 15. How does Airfree destroy dust mites? Mould reduction in the environment causes reduction in the mold dependant dust mite population. Airfree also destroys the harmful toxins and fungus freed by dust mite feces that trigger respiratory allergies. 16. How does Airfree eliminate fungi? As mentioned before, Airfree eliminates airborne microorganisms included fungi and spores. By eliminating spores new colonies are unlikely to develop, represent- ing l
Summary of the content on the page No. 20
FAQ - Frequently Asked Questions 22. Does Airfree need fi lter replacement? No. 23. Does Airfree consume a lot of energy? No. Airfree’s consumption is just 45 Watts for E60. 24. Where do the microorganisms go after they are incinerated? As all living organisms, microrganisms and their products are basically composed by carbon, oxigen and nitrogen. Since Airfree reachs nearly 200ºC, all the compo- nents are supposed to suffer a combustion process, which liberates carbone di- oxid