Summary of the content on the page No. 1
Instruction Manual Instruction Manual Instruction Manual Instruction Manual Instruction Manual Instruction Manual Instruction Manual
Instruction Manual
Airfree Enviro 60 Airfree Enviro 60
Airfree Enviro 60 Airfree Enviro 60 Airfree Enviro 60
The World’s Safest and most Tested Air Purifi er
Summary of the content on the page No. 2
Copyright 2001-2003 Policon Ltd. All Rights Reserved All rights reserved. No part of this publication may be reproduced, photocopied, transmitted, transcribed, stored in a retrieval system, or translated into any lan- guage in any form or by any means without the express prior written consent of Policon Ltd.
Summary of the content on the page No. 3
Index 3 Introduction Applications 4 7 Airfree and Mold 8 Technical Characteristics Airfree Description 9 Installing and Connecting 10 Safety Instructions 12 How does Airfree work? 13 14 Airfree’s Independent and Efficiency Tests FAQ - Frequently Asked Questions 15 19 Warranty 1
Summary of the content on the page No. 4
Congratulations for having purchased your Airfree. Airfree air purifiers are manufactured under license of US Patent 5,874,050, and many other patents pending worldwide. Airfree was designed with most advanced American and German technologies, to drastically destroy indoor airborne micro- organisms and reduce ozone. Different from other air purifier manufacturers, Airfree does not spend much time in describing fancy technologies with difficult words and theories. Airfree offers independent
Summary of the content on the page No. 5
The Invisible Enemies Most people spend around 90% of their time time indoors, at home or in the of- fice. The EPA – Environmental Protection Agency, claims the quality of air indoors can be 100 times worse than outdoors. Some factors contribute to indoor contamination: - High concentration of people in rooms increase fungus, bacteria and virus development, and cross contamination; - New building insulation techniques reduce outside air interchanges and con- sequently air condition
Summary of the content on the page No. 6
Applications Healthy rooms with pure clean air: The efficient and noiseless Airfree technology safely destroys mold spores, bacteria, viruses and other airborne organic microorganisms. Respiratory allergies and Asthma Airfree drastically reduces airborne organic allergens and Ozone, provid- ing cleaner and safer environment for allergic people. Airfree destroys mold spores, bacteria, viruses, dust mite allergens, pet dander and re- duces Ozone, all kept to minimum levels. Children and Newborns
Summary of the content on the page No. 7
Applications Offices, Public Buildings, Populated rooms, corridors, and elevators offer a constant contamination risk to employees and guests. This situation is aggravated by the flow of haz- ardous fungi and other microbes entering through the A/C system, and the ozone generated by computers and photocopiers. The spread of airborne transmittable diseases can accelerate in this environment. Airfree is a power- ful weapon in the reduction of airborne contamination by viruses, bacteria, fungi, a
Summary of the content on the page No. 8
Applications Pollens Pollens are no exception and like microorganims are totally destroyed when passing through Airfree patented sterilizing core. After being incinerated the resulting harmless particles are released back to the environment. Ozone (O3) Ozone is a very toxic gas that according to EPA can damage lung tissue, cause chest pain, throat irritation and trigger asthma. The FDA, the US Food and Drug Administration, recommends not to use any equipment directly or indirectly generati
Summary of the content on the page No. 9
Airfree and Mold Guide for Airfree Installation in Mold contaminated rooms 1 - Install your Airfree unit in accordance with the user manual 2 - Allow your unit to run for at least one week to achieve significant airborne mold spore reduction. 3 - Clean mold infected items and surfaces, since they are a continuous source of new spores. It is important to stress that Airfree will not destroy or remove mold from an infected item or surface. Those surfaces must be cleaned manually. Airfree will
Summary of the content on the page No. 10
Technical Characteristics Model Enviro 60 Capacity 2,000 cu.ft (60m³) Inside Temperature 392°F (200°C) Electric 46W Consumption Voltage 230v or 120v Noise Totally Silent Weight 4 lbs (1,8 Kg) 10 in height 8 in Ø Dimensions 25 cm height 20 cm Ø 8
Summary of the content on the page No. 11
Airfree Description 1 1- Top Lid with Air outlets 2 2- Grooves 3 3- On/Off Led 4- Feet 4 5- Fuse 6- Bottom lid 5 7- Power Cord 6 7 9
Summary of the content on the page No. 12
Installing and Connecting Plug power cord to the nearest outlet. Make sure the surface is dry (never place Airfree in wet floor or immerge in water) After 10 minutes the top lid should be warm. Place Airfree on the floor. Do not install it under furniture or shelves, behind curtains as it will reduce air flow and Airfree efficiency in reducing microorganisms. Place each Airfree in rooms up to 216 sq. ft. (24m²) . For larger rooms use proportionally additional Airfree units. The use of just on
Summary of the content on the page No. 13
Installing and Connecting Airfree can only be used in rooms with minimum air volume of 330 cu. ft. (10 m3), free of obstacles. Airfree can be installed in rooms equipped with air conditioning and heating systems. However it is recommended not to place Airfree nearby them to avoid potential interference in Airfree air flow. Do not place Airfree in the corridor to try to reach the whole house. In this case Airfree will only reduce air pollution in the corridor area. Airfree works better in ro
Summary of the content on the page No. 14
Safety Instructions Airfree can not be installed on wet surfaces or immerged in water like any other electric appliance. Please do not attempt to open Airfree or touch interior electric parts. Such attempt may cause electric shock hazard. If any mal function occurs please contact Airfree authorized repair centres or call the shop where Airfree was purchased. If there is a temporary loss of energy Airfree will take the same time to recover the previous contamination level. Do not place cl
Summary of the content on the page No. 15
How does Airfree Work? Purifi ed Air Cooling Chamber Cold and clean air is delivered to the environment without signifi cant change in room temperature and humidity. Sterilizing Ceramic Core Inside the ceramic core 99.99% of all microorganims are incinerated and eliminated from the environment Air Inlets Contaminated air enters Airfree by air convection Contaminated Air How Airfree works? Contaminated air silently enters Airfree by air convection and is sterilized
Summary of the content on the page No. 16
Airfree Independent and Efficiency Tests AIRFREE EFFICIENCY TESTS BY INDEPENDENT LABORATORIES, INSTITUTES AND UNIVERSITIES IN FOLLOWING COUNTRIES. Reduction of Microorganisms Laboratory Local Dust Mite alergens Fungus Bacteria DerP-1 Insect R&D Limited 70,6% to 97,95% Laboratory september to november, 2000 SGS Natec Institute* Hamburgo/Germany Laboratory Office 99% 99% september to november, 2000 Technical Micronics Control Huntesville/USA Laboratory 93% 78% april 28 to may 14, 199
Summary of the content on the page No. 17
FAQ - Frequently Asked Questions 1. How does Airfree work? Airfree incinerates microorganisms at its heated capillaries. Contaminated air is dragged into Airfree’s ceramic core by air convection and microorganisms are destroyed at high temperatures regardless of how resistant and dangerous they might be. 2. 2. Are there any side effects? Are there any side effects? No. Airfree’s new technology uses heat to purify the air. No side effects, no emissions, NO IONS, nor new particles are gene
Summary of the content on the page No. 18
FAQ - Frequently Asked Questions 9. Is it necessary to keep doors and windows closed? 9. Is it necessary to keep doors and windows closed? It is preferable. But opening window for 1 or 2 hours a day will not affect Airfree effi ciency. 10. Does 10. Does Airfree eliminate bacteria and viruses? Airfree eliminate bacteria and viruses? Yes. Unlike the air fi lters in the market Airfree is more effi cient with the smallest microorganisms as they are easily carried by Airfree’s airfl ow in
Summary of the content on the page No. 19
FAQ - Frequently Asked Questions 15. How does 15. How does Airfree destroy dust mites? Airfree destroy dust mites? Mold reduction in the atmosphere causes a reduction in the mold dependant dust mite population. Airfree also destroys the harmful toxins and fungus freed by dust mite feces that trigger respiratory allergies. 16. How does 16. How does Airfree eliminate fungi? Airfree eliminate fungi? As mentioned before, Airfree eliminates airborne microorganisms included fungi and spor
Summary of the content on the page No. 20
FAQ - Frequently Asked Questions 22. Does 22. Does Airfree need fi Airfree need fi lter replacement? lter replacement? No. Airfree’s technology uses just heat. 23. Does 23. Does Airfree consume a lot of energy? Airfree consume a lot of energy? No. Airfree’s consumption is just 46 Watts equivalent to a small light bulb. 18