Friedrich CP06E10 user manual

User manual for the device Friedrich CP06E10

Device: Friedrich CP06E10
Category: Air Conditioner
Manufacturer: Friedrich
Size: 3.03 MB
Added : 8/26/2013
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Friedrich CP06E10. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Friedrich CP06E10.

For your convenience

If looking through the Friedrich CP06E10 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Friedrich CP06E10 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Friedrich CP06E10 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Friedrich CP06E10 User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Friedrich CP06E10 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Friedrich CP06E10. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.sylvane.com 1-800-934-9194
Room Air Conditioner
Service and Parts
Manual
0F
Fan hr
Speed
Auto
Money Fan Cool Swing
Saver ® Only
Temp
Dry
Timer
0n /0ff Mode Power
CP08E10 CP06E10
CP06 CP08 SVC PARTS 2008(07/08)

Summary of the content on the page No. 2

www.sylvane.com 1-800-934-9194 Air Conditioner Service Manual TABLE OF CONTENTS Safety Precautions..........................................................................................................................................3 Dimensions .....................................................................................................................................................6 Outside Dimensions .................................................................................

Summary of the content on the page No. 3

www.sylvane.com 1-800-934-9194 Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury. WARNING This symbol indicates the possibility of injury or damage to property only. CAUTION  Meanings of symbols

Summary of the content on the page No. 4

www.sylvane.com 1-800-934-9194 Safety Precautions Plug in the power plug Do not operate or stop the Do not damage or use an properly. unit by inserting or pulling unspecified power cord. out the power plug. • Otherwise, it will cause • It will cause electric shock or • It will cause electric shock or electric shock or fire. fire. fire. Do not modify po Do not modify po Do not modify po Do not modify power cor wer cord Use the air conditioner on a Always plug into a length. single outlet circu

Summary of the content on the page No. 5

www.sylvane.com 1-800-934-9194 Safety Precautions If water enters the product, turn off the the Do not clean the air conditioner with water. power switch of the main body of appliance. Contact service center after taking the power- plug out from the socket. • It will cause electric shock or failure of • Water may enter the unit and degrade the machine. insulation. It may cause an electric shock. CAUTION Never touch the metal parts of the unit Do not block the inlet or outlet. when removing th

Summary of the content on the page No. 6

www.sylvane.com 1-800-934-9194 Dimensions Dimensions Symbols Used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that could cause harm to the air conditioner. NOTICE This symbol indicates special notes. Outside Dimensions 11 1 525(20 /16") 470(18 /2") 6 Room Air Conditioner 7 353(13 /8")

Summary of the content on the page No. 7

www.sylvane.com 1-800-934-9194 Specfications Pr Pr Pr Product Specifications oduct Specifications oduct Specifications oduct Specifications MODLES CP08E10 CP06E10 ITEMS POWER SUPPLY 1Ø, 115, 60Hz COOLING CAPACITY (Btu/h) 7 ,800 6,000 560 INPUT (W) 720 6.8 5.1 RUNNING CURRENT (A) E.E.R (BTU/W.h) 10.8 10.7 INDOOR ( C) 26.7(DB)* 19.4(WB)** OPERATING OUTDOOR ( C) 35(DB)* 2

Summary of the content on the page No. 8

www.sylvane.com 1-800-934-9194 Operation Operation • DESIGNED FOR COOLING ONLY • POWERFUL AND INCREDIBLE COOLING • TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE • BUILT-IN ADJUSTABLE THERMOSTAT • WASHABLE ONE-TOUCH FILTER • COMPACT SIZE Location and Function of Controls Service Manual 8

Summary of the content on the page No. 9

Oper Operation ation Oper Operation ation www.sylvane.com 1-800-934-9194 6 4 7 Air Power Purifier 1 0 F Temp Fan hr Speed 2 Fan Speed 4 Auto Swing Money Fan Cool Mode Timer Saver ® Only Temp 5 3 Dry Auto A Swing Swing Timer Power 0n /0ff Mode 6 3 2 1 5 6. AUTO SWING dry operation. This button can automatically control the air flow (dehumidify operation) direction(left+right). 7 To receive the signal from remote controller. 9 Room Air Conditioner

Summary of the content on the page No. 10

www.sylvane.com 1-800-934-9194 Disassembly Disassembly — Before the following disassembly, POWER SWITCH set to OFF and disconnect the power cord. Mechanical Parts 1. FRONT GRILLE 1. Open the lnlet grille upward or downward. 2. Remove the screw which fastens the front grille. 3. Pull the front grille from the right side. 4. Remove the front grille. 5. Re-install the component by referring to the removal procedure, above.(See Figure 17) Figure 17 2. CABINET 1. After disassembling the FRONT GRILLE,

Summary of the content on the page No. 11

www.sylvane.com 1-800-934-9194 Disassembly Air Handling Parts 1. AIR GUIDE AND BLOWER 1. Remove the front grille. 2. Remove the cabinet. 3. Remove the control box. 4. Remove the 3 screws which fasten the brace. 5. Remove the brace. 6. Remove the 2 screws which fasten the evaporator. 7. Move the evaporator forward and pulling it upward slightly. (See Figure 20) 8. Move the evaporator to the left carefully. Figure 20 9. Pull out the hook of orifice by pushing the tabs and remove it. (See Figure

Summary of the content on the page No. 12

www.sylvane.com 1-800-934-9194 Disassembly 3. MOTOR 1. Remove the cabinet. 2. Remove the evaporator. 3. Remove the orifice. 4. Remove the blower. 5. Remove the fan. 6. Remove the control box cover and housing of the motor in the control box. 7. Remove the 2 screws which fasten the motor from the mount motor. (See Figure 23) 8. Remove the motor. 9. Re-install the components by referring to the Figure 23 removal procedure, above.(See Figure 23) Electrical Parts 1. OVERLOAD PROTECTOR 1. Remov

Summary of the content on the page No. 13

www.sylvane.com 1-800-934-9194 Disassembly 3. CAPACITOR 1. Remove the control box. 2. Remove the screw which fasten control panel from control box. 3. Remove the screw which located in the front. 4. Open the bottom side of control box. 5. Remove the screw and the clamp which fastens the capacitor. 6. Disconnect all the leads of capacitor terminals. 7. Re-install the components by referring to the Figure 26 removal procedure, above. (See Figure 26) 4. POWER CORD 1. Remove the control box. 2. Open

Summary of the content on the page No. 14

www.sylvane.com 1-800-934-9194 Disassembly 2. EVAPORATOR 1. Remove the cabinet. 2. Remove the 2 screws which fasten the evaporator. 3. Move the evaporator sideways carefully. 4. After discharging the refrigerant completely, unbraze the interconnecting tube at the evaporator connections. 5. Remove the evaporator carefully. 6. Re-install the component by referring to notes. (See Figure 29) 3. CAPILLARY TUBE 1. Remove the cabinet. 2. After discharging the refrigerant completely, unbraze the interc

Summary of the content on the page No. 15

www.sylvane.com 1-800-934-9194 Disassembly Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. Figure 30B-Charging Figure 30A-Pulling Vacuum Service Manual 15 COMPOUND GAUGE CONDENSER (HIGH PRESSURE SIDE) MANIFOLD GAUGE B A CAPILLARY TUBE SEE INSETS BELOW EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR LOW HI A B A B EXTERNAL VACUUM PUMP CH

Summary of the content on the page No. 16

www.sylvane.com 1-800-934-9194 Schematic Diagram Circuit Diagram  1 6 2 4 7 5 3 8 LOCATION Q'TY DESCRIPTION NO. PER SET 1 POWER CORD ASSEMBLY 1 2 FAN MOTOR 1 3 COMPRESSOR 1 4 DISPLAY P.W.B ASSEMBLY 1 5 MAIN P.W.B ASSEMBLY 1 6 THERMISTOR 1 7 CAPACITOR 1 8 OWERLOAD PROTECTOR 1 Service Manual 16

Summary of the content on the page No. 17

www.sylvane.com 1-800-934-9194 Schematic Diagram Electronic Control Device 17 Room Air Conditioner

Summary of the content on the page No. 18

www.sylvane.com 1-800-934-9194 Schematic Diagram Components Location(For Main P.W.B ASM) Service Manual 18

Summary of the content on the page No. 19

www.sylvane.com 1-800-934-9194 Troubleshooting Guide Troubleshooting Guide Piping System CONDENSER COIL FAN CAPILLARY TUBE MOTOR COMPRESSOR BLOWER EVAPORATOR COIL Figure 38 is a brief description of the important components and their function in what is called the refrigeration system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle. ROOM AIR CONITIONER CYCLE OF REFRIGERATION EVAPORATOR COILS CONDENSER COILS VAPOR INLET SUCTION LI

Summary of the content on the page No. 20

www.sylvane.com 1-800-934-9194 Troubleshooting Guide Troubleshooting Guide In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application. Unit runs but poor cooling. Ineffective Cooling Check cold air Check outdoor coil Check heat load circulation for smooth (heat exchanger) and increase. flow. fan operatio


Alternative user manuals
# User manual Category Download
1 Friedrich 000 BTU'S User manual Air Conditioner 23
2 Friedrich 115 Volts US10 User manual Air Conditioner 23
3 Friedrich 18 User manual Air Conditioner 11
4 Friedrich 115 Volts UE08 User manual Air Conditioner 7
5 Friedrich 2003 User manual Air Conditioner 6
6 Friedrich 115 Volts US12 User manual Air Conditioner 12
7 Friedrich 2006 User manual Air Conditioner 5
8 Friedrich 1883 User manual Air Conditioner 8
9 Friedrich 000 BTU/h User manual Air Conditioner 1
10 Friedrich 115 Volts US08 User manual Air Conditioner 2
11 Friedrich 2007 User manual Air Conditioner 2
12 Friedrich 2008 User manual Air Conditioner 2
13 Friedrich 230 Volts US10 User manual Air Conditioner 7
14 Friedrich 2009 User manual Air Conditioner 3
15 Friedrich 24 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21