Friedrich CP05C10 user manual

User manual for the device Friedrich CP05C10

Device: Friedrich CP05C10
Category: Air Conditioner
Manufacturer: Friedrich
Size: 0.96 MB
Added : 8/26/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Friedrich CP05C10. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Friedrich CP05C10.

For your convenience

If looking through the Friedrich CP05C10 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Friedrich CP05C10 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Friedrich CP05C10 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Friedrich CP05C10 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Friedrich CP05C10 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Friedrich CP05C10. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Room Air Conditioner
Service and Parts
Manual
CP05C10
CP05.Svc(05/06)

Summary of the content on the page No. 2

CONTENTS 1. PREFACE ...................................................................................................................................................3 1.1 FEATURES.....................................................................................................................................................3 1.2 SPECIFICATIONS .........................................................................................................................................3 1.3 LOCAT

Summary of the content on the page No. 3

1. PREFACE This service manual provides various service information, including the mechanical and electrical parts, etc. This room air conditioner was manufactured and assembled under a strict quality control system. The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit. 1.1 FEATURES • DESIGNED FOR COOLING ONLY • BUILT-IN ADJUSTABLE THERMOSTAT • WASHABLE ONE-TOUCH FILTER • COMPACT SIZE 1.2 SPECIFICATIONS MODELS CP05C10 ITEMS COOLING

Summary of the content on the page No. 4

1.3 LOCATIONS OF CONTROLS 1 TEMPERATURE SETTING • These buttons control the temperature of the room. The temperature can be set within a range of 60°F to 86°F, in increments of 1°F. 2 MONEY SAVER The fan stops when the compressor stops cooling. 1 • Approximately every 3 minutes the fan will turn on and sample the room air to determine if more cooling is needed. 2 3 OPERATION MODE SELECTOR 3 • Everytime you push this button, it will rotate between the COOL, FAN and DRY modes. 4 ON/OFF TIMER 4

Summary of the content on the page No. 5

2. DISASSEMBLY INSTRUCTIONS 2.1 MECHANICAL PARTS 2.1.1 FRONT GRILLE Figure 1 1. Pull the inlet grille forward. 2. Remove the screw securing the Front Grille. (Fig. 3) 3. Push the grille up from the bottom and pull the top of the grille away from the case to lift the top tabs out of their slots. (Fig. 4) 4. Carefully position the grille, bottom first, and snap back into place. 5. Reposition the screw that secures the front grille Figure 2 2.1.2 CABINET 1. Disconnect the unit from the power sour

Summary of the content on the page No. 6

Figure 6 2.2 AIR HANDLING PARTS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the power source. 2. Remove the front grille. (Refer to Section 2.1.1) 3. Remove the cabinet. (Refer to Section 2.1.2) 4. Remove the control panel. (Refer to Section 2.1.3) 5. Remove 2 screws that secure the upper air guide to air guide lower. (See Figure 6) 6. Lift upper air guide upward. 7. Re-install by referring to the procedures above. Figure 7 2.2.2 ORIFICE, TURBO FAN AND FAN 1. Disconnect the unit fr

Summary of the content on the page No. 7

2.2.3 MOTOR Figure 10 1. Disconnect the unit from the power source. 2. Remove the front grille. (Refer to Section 2.1.1) 3. Remove the cabinet. (Refer to Section 2.1.2) 4. Remove the control panel. (Refer to Section 2.1.3) 5. Remove the upper air guide. (Refer to Section 2.2.1) 6. Remove the compressor, turbo fan, fan and shroud. (Refer to Section 2.2.2) 7. Remove 2 screws that secure the motor to the motor mount . (See Figure 10) 8. Remove the motor. 9. Re-install by referring to the proce

Summary of the content on the page No. 8

2.3.2 COMPRESSOR Figure 14 1. Remove the front grille and cabinet. (Refer to Section 2.1) 2. Discharge the refrigerant by using a refrigerant recovery system. 3. Remove the overload protector. (Refer to Section 2.3.1) 4. After discharging the unit completely, unbrace the suction and discharge pipes at the compressor connections. 5. Remove 3 nuts which fasten the compressor. 6. Remove the compressor. 7. Re-install by referring to the removal procedure above. (See Figure 14) 2.3.3 CAPACITOR 1.

Summary of the content on the page No. 9

Figure 18 2.3.6 POWER CORD 1. Disconnect the unit from source of power. 2. Remove the front grille. (Refer to Section 2.1.1) 3. Remove the cabinet. (Refer to Section 2.1.2) 4. Remove a screw that secures control panel to base pan. (Refer to Section 2.1.3) 5. Pulls the control board toward you. 6. Disconnect the 2 receptacles and remove the grounding screw. 7. Remove a screw securing the clip with cord to the control panel. 8. Pull the power cord. 9. Re-install by referring to procedures above.

Summary of the content on the page No. 10

wise. This will keep oil from foaming and being 2.4.2 EVAPORATOR drawn into the vacuum pump. 1. Remove the cabinet. 2. Discharge the refrigerant by using a refrigerant 6-3. Operate the vacuum pump for 20 to 30 min- recovery system. utes, until 600 micron vacuum is obtained. 3. Remove the upper air guide . (Refer to Section Close valves A and B and observe vacuum 2.2.1) gauge for a few minutes. 4. After discharging the refrigerant completely, A rise in pressure would indicate a possible unbra

Summary of the content on the page No. 11

Equipment needed: Vacuum pump, charging cylinder, manifold gauge, brazing equipment, pinch-off tool capable of making a vapor proof seal, leak detector, tubing cutter, hand tools to remove components and service valve. COMPOUND GAUGE MANIFOLD GAUGE B A CONDENSER SEE INSETS (HIGH PRESSURE SIDE) BELOW COMPRESSOR EVAPORATOR (LOW PRESSURE SIDE) CAPILLARY TUBE LO HI CHARGING CYLINDER A A B B EXTERNAL VACUUM PUMP C Figure 21A-Pulling Vacuum Figure 21B-Charging —11—

Summary of the content on the page No. 12

2.4.4 ELECTRICAL DATA Line Cord Plug Use Wall Receptacle Power Supply Do not under any circumstances cut Use 15 AMP, time or remove the delay fuse, or circuit grounding prong from the plug. breaker. Power supply cord with Standard 125V, 3-wire grounding 3-prong grounding plug receptacle rated 15A, 125V AC USE OF EXTENSION CORDS Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA certified/UL-liste

Summary of the content on the page No. 13

3.2 PIPING SYSTEM CONDENSER COILS FAN MOTOR CAPILLARY TUBE TURBO FAN EVAPORATOR COILS Following is a brief description of the important components and their function in what is called the refrigeration system. Reference should be made to Figure 32 to follow the refrigerating cycle and the flow of the refrigerant in the cooling cycle. ROOM AIR CONDITIONER CYCLE OF REFRIGERATION EVAPORATOR COILS CONDENSER COILS VAPOR INLET SUCTION LINE HOT COMPLETE LIQUID COOL LOW PRESSURE VAPOR DISCHARGED BOIL

Summary of the content on the page No. 14

3.3 TROUBLESHOOTING GUIDE In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused by an electrical defect. The other is Ineffective Air Con- ditioning caused by a defect in the refrigeration circuit and improper application. Unit is running but cooling is ineffective. Ineffective Cooling Check cold air Check outdoor coil Check heat load circulation for smooth (heat exchanger) and increase. flow. fan operation. Clean condenser. Dirty i

Summary of the content on the page No. 15

Fails to Start Check of circuit breaker Check voltage power source. and fuse. Check control switch Gas leakage of feeler setting. bulb of thermostat. Check control switch. Compressor fails to Fan fails to start. start. Improper wiring. Improper thermostat Drop of power voltage. setting Defect of fan motor or capacitor. Defect of compressor or Loose terminal capacitor. connection Irregular motor resistance (Ω ) Capacitor check. Improper wiring Irregular motor insulation

Summary of the content on the page No. 16

ROOM AIR CONDITIONER VOLTAGE LIMITS NAME PLATE RATING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V COMPLAINT CAUSE REMEDY Fan motor will not run. No power Check voltage at outlet. Correct if none. Power supply cord Check voltage to electronic control board. If none, check power supply cord. Replace cord if circuit is open. Wire disconnected or Connect wire. Refer to wiring diagram for connection loose terminal identification. Repair or replace loose terminal. Capacitor (Discharge Test capac

Summary of the content on the page No. 17

COMPLAINT CAUSE REMEDY Fan motor noise. Fan blade If cracked, out of balance, or partially missing, replace it. Blower wheel If cracked, out of balance, or partially missing, replace it. Loose set screw Tighten it. Worn bearings If knocking sounds continue when running replace the motor. If the motor hums or noise appears to be internal while running, replace motor. Compressor will not run, Voltage Check voltage. See the limits on the preceding fan motor r

Summary of the content on the page No. 18

COMPLAINT CAUSE REMEDY Compressor cycles on Fan motor If not running, determine the cause. Replace if overload. required. Condenser air flow Remove the cabinet, inspect the interior surface restriction of the condenser. If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush. Clean the interior base before re-assembling. Condenser fins If the condenser fins are closed over a large (damaged) area on the coil surface, head pressures will increase, causing the co

Summary of the content on the page No. 19

4. CIRCUIT DIAGRAM POWER INPUT WH(BL) BK(BR) (Ribbed) (Plain) GN/YL(GN) THERMISTOR BK BK BL BL CN-TH1 RD RD MOTOR OR(BR) OR(BR) YL YL GN/YL (GN) CAPACITOR F C OR SYNC MOTOR BK WH RD H BK RY-SYNC BK ZNR R RD RY-COMP COMP. S 43 TRANS BL BL C FORMER FUSE 250V/T2A OLP (115V/T2A) 3854A20022K WIRING DIAGRAM PART NO. LOCATION Q'TY DESCRIPTION NO. PER SET CP05C10 67300020 1 1 POWER CORD ASSY 2 FAN MOTOR 67303026 1 3 COMPRESSOR 67301616 1 67300718 4 CAPACITOR

Summary of the content on the page No. 20

5. EXPLODED VIEW 749740 130910 559011 W48602 554030 149980 267110 349480 132111-1 132111-2 135312 352390-1 147582-1 147581 359012 346811 W48602 159900-1 152302 352390 354210 130410 135303 135313 W0CZZ 269310 552102 352111 352115 567502 352113 137215 554160 268714 263230 35211A 550140 238310 268712 249950 —20—


Alternative user manuals
# User manual Category Download
1 Friedrich 000 BTU'S User manual Air Conditioner 23
2 Friedrich 115 Volts US10 User manual Air Conditioner 23
3 Friedrich 18 User manual Air Conditioner 11
4 Friedrich 115 Volts UE08 User manual Air Conditioner 7
5 Friedrich 2003 User manual Air Conditioner 6
6 Friedrich 115 Volts US12 User manual Air Conditioner 12
7 Friedrich 2006 User manual Air Conditioner 5
8 Friedrich 1883 User manual Air Conditioner 8
9 Friedrich 000 BTU/h User manual Air Conditioner 1
10 Friedrich 115 Volts US08 User manual Air Conditioner 2
11 Friedrich 2007 User manual Air Conditioner 2
12 Friedrich 2008 User manual Air Conditioner 2
13 Friedrich 230 Volts US10 User manual Air Conditioner 7
14 Friedrich 2009 User manual Air Conditioner 3
15 Friedrich 24 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21