Friedrich EM24 user manual

User manual for the device Friedrich EM24

Device: Friedrich EM24
Category: Air Conditioner
Manufacturer: Friedrich
Size: 1.89 MB
Added : 8/26/2013
Number of pages: 56
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Friedrich EM24. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Friedrich EM24.

For your convenience

If looking through the Friedrich EM24 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Friedrich EM24 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Friedrich EM24 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Friedrich EM24 User manual - Online PDF
Advertisement
« Page 1 of 56 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Friedrich EM24 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Friedrich EM24. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Temperature
Cooler Warmer
Cool Power
Fan Fan Money
®
Only Speed Saver
Timer Operation
On/Off Start Stop Set Hr.
Room Air Conditioners
Standard Chassis Models
115-Volt: SS08, SS10, SS12, SS14
230-Volt: SS12, SS16, SM18, SM21, SM24
115-Volt: KS12, KS15
230-Volt: KM18, KM24
230-Volt: SL28, SL36
HEAVY DUTY
115-Volt: YS09
230-Volt: YS13, YM18, YL24, ES12, ES16, EM18, EM24, EL36
Register your air conditioner
Model information can be found on the name
plate behind the front cover.
Please complete and

Summary of the content on the page No. 2

920-198-00 Congratulations! You have purchased the very latest in room air conditioner technology. Your new Friedrich high effi ciency room air conditioner will give you many years of de- pendable service. Many extra features have been built into your Friedrich air conditioner to assure quiet operation, the best circulation of cool, dry air, functional controls, and the most economical operation. Table of contents Air Conditioner Operation Before Operating Your Unit .............................

Summary of the content on the page No. 3

920-198-00 WARNING: Before operating your unit Make sure the wiring is adequate for your unit. CIRCUIT RATING REQUIRED WALL If you have fuses, they should be of the time delay type. Before you install OR TIME DELAY RECEPTACLE or relo cate this unit, be sure that the amperage rating of the circuit breaker FUSE MODEL or time delay fuse does not exceed the amp rating listed in Figure 1. NEMA AMP VOLT NO. DO NOT use an extension cord. The cord provided will carry the proper amount of electric

Summary of the content on the page No. 4

920-198-00 How to operate your Friedrich room air con diti on er (QuietMaster Programmable) To start unit 1 If your air conditioner is installed and plugged into a proper re- Figure 3 cep tac le, it is ready to go. Touch Power button once. The unit will automatically be in Cool mode with the temperature set at 75°F (24°C) and the fan speed at F1, the sleep setting. There is a 3- PM minute delay before the compressor will turn on. (See "Automatic Component Protection" on this page). DISPLAY

Summary of the content on the page No. 5

920-198-00 * How to use the remote control (QuietMaster Programmable) To start unit To set the timer 1 POWER - Press the Power button once. The unit will automatically NOTE: Set the hour clock before attempting to set timer functions. You turn on in the mode and fan speed it was last left on. can set the timer On/Off a minimum of one hour apart, and a maximum of 23 hours apart. To set mode of operation 9 TIMER START - Press Start to view the current start time for cool- ing. Continue press

Summary of the content on the page No. 6

920-198-00 How to operate your Friedrich room air con diti on er (QuietMaster 'K' & Heavy Duty models / Twintemp models) To start unit If your air conditioner is installed and plugged into a properly grounded re cep ta cle, it is ready to oper ate. Mode control (QuietMaster ‘K’ and Heavy Duty) The upper dial (Figure 5) allows you to select cooling at four different Off SPEED speeds, as well as Fan Only (Models SL28 and SL36 only have three cooling speeds.). Fan Sleep Only Setting Off - to

Summary of the content on the page No. 7

920-198-00 Care and Maintenance / Fresh air and exhaust control To remove, wash and replace filter and return air grille Open the return air (RA) grille by grasping it at the top outside edges and pulling towards you (See Figure 7). The RA grille will stay open until it is detached or closed (it is easier to completely detach the grille before closing it). To remove the RA grille, grasp it at the bottom and pull towards you. The fi lter is held in place by two spring clips (See Figure 7). Push

Summary of the content on the page No. 8

920-198-00 Installation In structi ons ® NOTE: This manual includes installation instructions for window mount and thru-the-wall mount methods. TwinTemp heat/cool units are designed for permanent thru-the-wall installation. Mounting the unit in a window will require a window mounting accessory kit, available through your Friedrich dealer. Read This First! Electrical Requirements IMPORTANT: Before you begin the actual installation of your air conditioner, Refer to the electrical data plate loca

Summary of the content on the page No. 9

920-198-00 Window Mount Thru-the-wall Installation Hardware Installation Hardware ITEM ITEM DE SCRIP TION QTY. QTY. DE SCRIP TION NO. NO. MOUNT ING PARTS SHELL MOUNT ING PARTS 4 SCREW, SHEET METAL #12A x 2" 7 1 SUPPORT BRACKET 2 14 CHASSIS SEAL GASKET (LIGHT FOAM) 1 2 SCREW, 10-24 x 1" HEX HEAD 4 3 10-24 FLAT WELD NUT 4 4 SCREW, SHEET METAL #12A x 2" 7 WINGBOARD ANGLE MOUNTING 5 WINGBOARD ANGLE, TOP 1 6 WINGBOARD ANGLE, SIDE 2 3 7 SCREW, SHEET METAL #8A x ⁄8" 2 WINGBOARD MOUNTI

Summary of the content on the page No. 10

920-198-00 Standard Sash Window Installations STEP 1 Remove decorative plastic return air grille to a safe area away STEP 5 Anchor the side angles (Item #6) by engaging the tabs at each from unit. The return air grille can be removed by pulling at the end of the sill plate (see Figure B) with the bottom loops of the sides on either the top or bottom. side angle. Engage the tabs at each end of the top angle (Item #5) with the top loops of the side angle (see Figure B). Install STEP 2 Also re

Summary of the content on the page No. 11

920-198-00 STEP 8 OUTSIDE SUPPORT MOUNTING – Assemble the support Figure C brackets (Item #1) to the bottom rails of the cabi net with four (4) 10-24 1" long screws (Item #2) and four (4) 10-24 fl at nuts TOP (Item #3). Adjust the support brackets to bring the bottom pads SUPPORT CENTER ANGLE CABINET IN in contact with the wall surface. (A 1" x 4" or 2" x 4" SPACER WINDOW SIDE PULL SHOULD BE USED BETWEEN THE WALL AND THE TO SIDE. WINDOW SUPPORT BRACKETS WHEN IN STALLED ON ALU MI NUM

Summary of the content on the page No. 12

920-198-00 Figure 1A TYPICAL MOUNTING SCHEME Figure 2A MODIFIED MOUNTING SCHEME 10 - 24 SCREW ⅜" SLOPE DOWN 10 - 24 FLAT NUT ⅜" SLOPE DOWN SUPPLY AIR CONDENSER AIR OUTLET RETURN AIR CUT DIMENSION "A" HERE CONDENSER AIR INLETS STONE LEDGE #12A x 2" SHEET METAL OUTSIDE WALL SCREW 1" x 4" OR 2" x 4" SPACER CUT TO FIT DIMENSION "A" DISCARD BE TWEEN WALL AND AND BEND DOWN TO FORM A SHADED AREA BRACKET SHOULD BE VER TI CAL LEG. USED ON ALUMINUM, ASBESTOS OR VINYL SIDING. Figure 3A

Summary of the content on the page No. 13

920-198-00 STEP 11 INSTALL THE SIDE WINGBOARD PANELS – Be sure the STEP 13 When possible, caulk the outside of the installation with cabinet has been secured to the wind ow sill and that the out- industrial type caulking to prevent weather l eaks. side support brackets have been installed as shown in Figure STEP 14 INSTALL CHASSIS – After installing the shell, slide the chassis D. Raise the window sash and install the right and left side into the shell stopping approximately 3" from full

Summary of the content on the page No. 14

920-198-00 STEP 16 OPTIONAL: The factory assembles the supply cord so that STEP 17 Be sure the fi lter is in place before installing the return air grille it exits the left side of the unit. At the consumer’s discretion, (See Figure J), and that the electrical cord is properly routed the supply cord can be made to exit the right side of the unit. so not to interfere with the installation. (See Step 16.) To do this, remove the black rubber coated cord clamp from STEP 18 Pick up the grille

Summary of the content on the page No. 15

920-198-00 Through-the-wall Installations The following instructions apply to wood, masonry, brick, concrete or cinder block wall con struc tion STEP 1 Follow steps 1, 2, 3 and 4 of the "STANDARD SASH WINDOW STEP 3 WALL PREPARATION – The maximum wall thickness permis- INSTALLATION" instructions beginning on page 10. sible without special construction is de term ined by the model size to be installed. THE OUTSIDE CABINET CONDENSER-AIR- STEP 2 CABINET PREPARATION – Remove the sill plate from the

Summary of the content on the page No. 16

920-198-00 STEP 4 CHECKING WIRING AND PLUMBING: Check all wiring and Figure D plumbing inside and outside of the wall to be sure none will be BRICK VENEER CONSTRUCTION broken where the hole is to be cut. STEP 5 HOLE CONSTRUCTION: Depending upon size of unit to be SHIM VOID SPACES AT TOP AND installed, lay out the hole dimensions per the chart below. Cut SIDES WITH WOOD AS REQUIRED and frame in hole to fi nished dimensions. Use 2" x 4" material for framing and follow the suggested typical i

Summary of the content on the page No. 17

920-198-00 Figure F TYPICAL INSTALLATION CAULK ALL SIDES WEATHER TIGHT TRIM MOULDING ⅜" SLOPE DOWN SCREW #12A x 2" NOTE: SUPPORT BRACKETS MAY BE OMIT TED LONG (USE 3) FROM THROUGH-THE-WALL IN STAL LA TIONS IF THE CABINET IS SECURED AS FOL LOWS. DRILL 2 HOLES IN EACH SIDE AND IN STALL 4 FAS TEN ERS (2 EACH SIDE). USE #12 x 2" SCREWS, TOGGLE BOLTS OR EX PAN SION ANCHOR BOLTS AS SHOWN IN STEP 7. CABINET SILL PLATE GUIDE CHANNEL SUPPORT BRACK ETS (AVAILABLE AS OPTI ONAL AC CES SORY ) SCREW

Summary of the content on the page No. 18

920-198-00 Troubleshooting tips Power failure Noises If you have a power failure, the unit's auto-restart feature will resume All air conditioners make some noise. Friedrich QuietMaster® units are operation in the selected mode prior to the power failure. designed to operate as quietly as possible. An air conditioner mounted in a wall is quieter than one mounted in a window. It is important to ensure Won't cool? that the chassis seal gasket is properly installed (refer to installation If yo

Summary of the content on the page No. 19

920-198-00 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units and/or

Summary of the content on the page No. 20

920-198-00 ¡Enhorabuena! Acaba de comprar la tecnología más avanzada en unidades de aire acondicionado de tipo ventana. Su unidad de aire acondicionado de tipo ventana Friedrich le dará muchos años de servicio de confi anza. Este modelo incorpora muchas características para garantizar el funcionamiento silencioso, la mejor circulación posible del aire frío, aire seco, controles funcionales y un funcionamiento económico. Contenido Funcionamiento del aire acondicionado Antes de utilizar la unidad


Alternative user manuals
# User manual Category Download
1 Friedrich 000 BTU'S User manual Air Conditioner 23
2 Friedrich 115 Volts US10 User manual Air Conditioner 23
3 Friedrich 18 User manual Air Conditioner 11
4 Friedrich 115 Volts UE08 User manual Air Conditioner 7
5 Friedrich 2003 User manual Air Conditioner 6
6 Friedrich 115 Volts US12 User manual Air Conditioner 12
7 Friedrich 2006 User manual Air Conditioner 5
8 Friedrich 1883 User manual Air Conditioner 8
9 Friedrich 000 BTU/h User manual Air Conditioner 1
10 Friedrich 115 Volts US08 User manual Air Conditioner 2
11 Friedrich 2007 User manual Air Conditioner 2
12 Friedrich 2008 User manual Air Conditioner 2
13 Friedrich 230 Volts US10 User manual Air Conditioner 7
14 Friedrich 2009 User manual Air Conditioner 3
15 Friedrich 24 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21