Congratulations! Thank you for choosing Friedrich. Your Friedrich unit is designed for maximum comfort and quietness. Table of Contents Introduction ..................................................................................2 Safety Precautions.......................................................................3 How to operate your Friedrich ...................................................5 Adjusting the Air Flow Direction.................................................6 Care and M
Summary of the content on the page No. 3
G N E Introduction Before Operating Your Unit Make sure the wiring is adequate or our unit. f y If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in figure 1. r DO NOT use an extension co d. The cord provided will carry the proper amount of electrical power to the unit; an extension cord will not. Make sure that the receptacle is compa
Summary of the content on the page No. 4
ENGLISH Safety Precautions To prevent injury and property damage, follow these instructions. ■Incorrect operation due to ignoring instructions can cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION properties only. ■Meanings of symbols used in this manual are as shown below. Never Do This Always Do This WARNING Plug in the
Summary of the content on the page No. 5
Summary of the content on the page No. 6
6 4 7 Air Power Purifier 1 0 F Temp Fan hr Speed 2 Fan Speed 4 Auto Swing Money Fan Cool Mode Timer Saver® Only Temp 5 3 Dry Auto A Swing Swing Timer Power 0n /0ff Mode 6 3 2 1 5 6.AUTOSWING dry operation. This button can automatically control the air flow (dehumidify operation) direction. 7 To receive the signal from remote controller.
Summary of the content on the page No. 7
ENGLISH Adjusting the Air Flow Direction Vent Control For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation. OPEN the vent to discharge stale air. Part B CLOSE VENT OPEN NOTE : Before using the ventilation feature, position the lever, as shown. First, pull down part A to horizontal line with par . t B Part A Adjusting the Air Flow Direction Airflow can be adjusted by changing the direction of the air conditioner's louvers. • Adjusting Horizontal Air Flow Dir
Summary of the content on the page No. 8
Care and Maintenance Turn the power off and unplug the power plug before cleaning the air conditioner. Air Filter The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner. How to remove the air filter 1. Open the inlet grille upward by pulling out the bottom of the inlet grille.(a) 2. Remove the air filter from the front grille assembly by pulling the air filter up slightly. 3. Wash t
Summary of the content on the page No. 9
Timer Mode Fan Speed Temp Purifier Power Air ENGLISH 0F SpFeaend hr Auto Money Fan Cool Swing Saver® Only Dry Temp Timer Power 0n/0ff Mode Hardware Location Product Features CAUTION This appliance should be installed in accordance with local and national wiring regulations. This manual acts as a guide to help to explain product features. Vertical Air Deflector (Horizontal Louver) Horizontal Air Deflector (Vertical Louver) Air Discharge Air Intake(Inlet Grille) Cabinet Air Filter Front Grill Rem
Summary of the content on the page No. 10
ENGLISH Installation Instructions Read these instructions completely and carefully. Tools You Will Need ❒ Phillips-head screwdriver ❒ Scissors or knife ❒ Flat-blade screwdriver ❒ Pencil ❒ Ruler or tape measure ❒ Level ❒ Hammer Before You Begin NOTE TO INSTALLER: Leave these CAUTION: instructions with the air conditioner after Do not under any circumstances, cut or remove installation is complete. the third (ground) prong from the power cord. Do not change the plug on the power cord of NOTE TO CO
Summary of the content on the page No. 11
ENGLISH How to Install the Unit 1. To prevent vibration and excess noise, Fence make sure the unit is installed securely Awning and firmly. Cooled air 2. If possible Install the unit where the sunlight Heat does not shine directly on the unit. radiation 3. The outside of the cabinet must extend outward for at least 12" and there should be no obstacles, such as a fence or wall, 1 About /2" within 20" from the back of the cabinet, as Over 20" it will prevent heat radiation
Summary of the content on the page No. 12
Installation Kit Contents Type B:3EA Type A:13EA Type C:5EA 1 2 3 (SCREW) (SCREW) (SCREW) Type E:2EA Type D:2EA Type F:2EA Type G:2EA 7 5 6 4 (FRAME CURTAIN) (NUT) (SILL SUPPORT) (BOLT) 10mm 10 Type H:1EA Type K:2EA Type L:1EA Type M:1EA 8 11 9 (FOAM-STRIP) (FRAME-GUIDE) (WINDOWLOCKINGBRACKET) (FOAM-PE) Type N:1EA 12 (DRAIN JOINT PIPE) Have the following tools available for installation: * Screwdriver (Slotted and Phillips) * Ruler * Knife * Hammer * Pencil * Level 11 10mm 16mm 16mm
Summary of the content on the page No. 13
ENGLISH 0 F Fan hr Speed Money Fan Cool SAwuintog Saver® Only Temp Dry T 0n imer /0ff Mode Power 0 F Fan hr Speed Auto Money Fan Cool Swing Saver® Only Dry Temp Timer 0n/0ff Mode Power Suggested Tool Requirements SCREWDRIVER(+, -), RULER, KNIFE, HAMMER, PENCIL, LEVEL Shipping screws PREPARATION OF CHASSIS 1. Remove the screws which fasten the cabinet at both sides and at the back. (Fig .1) 2. Slide the unit out from the cabinet by gripping the base pan handle and pulling forward while bracing th
Summary of the content on the page No. 14
Cabinet Installation 1. Open the window. Mark a line on center of the window stool.Carefully place the cabinet on the window stool and align the center mark on the bottom front with the center line marked in the window stool. (Fig. 1) Upper Guide Window stool Front Angle Fig. 1 2. Pull the bottom window sash down behind the Upper Guide until they meet. (Fig. 2) Window Sash Upper guide NOTE: Do not pull the window sash down so 11 Foam-PE tightly that the movement of Frame 5 Curtain is restricted
Summary of the content on the page No. 15
0F SpFeaend hr Money Fan Cool SAwuintog Saver ® Only Dry Temp Timer 0n/0ff Mode Power 1 6. The cabinet should be installed with a very slight tilt (about 1/2") downward toward the outside Screw(Type B) 2 (See Fig. 5). Adjust the bolt and the nut of 6 Sill Support for balancing the cabinet. 6 Sill Support 7. Attach the cabinet to the window stool by driving Sash track the screws 2 [Type B: Length 16mm (5/8 inch) and below.] through the front angle into window stool. (Fig. 5) 5 8. Pull each Frame
Summary of the content on the page No. 16
12. Attach the Window Locking Bracket 10 with a Type C Window locking screw . ( Fig. 9) 3 bracket 10 Fig. 9 13. Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet. Push the grille in until it snaps into place. (Fig. 10) Fig. 10 14. Pull down the inlet grille and secure it with a Type A screw through the front grille. ( Fig. 11) 1 15. Window installation of room air conditioner is now completed. See ELECTRICAL DATA for plugging t
Summary of the content on the page No. 17
Through-the-Wall Installation Instructions-Optional The case may be installed through -the-wall 1 (cont.) IMPORTANT in both existing and new construction. D Secure with 14 wood screws anchored at Read completely, then follow step-by-step. Ieast an inch into the wall support structure. NOTE: Obtain all materials locally for NOTE: Drill pilot holes, if necessary, for mounting the air conditioner through- proper installation. If the frame is oversized, the wall. - use shims to prevent case distorti
Summary of the content on the page No. 18
Troubleshooting Tips Troubleshooting Tips save time and money! Review the chart below first and you may not need to call for service. Normal Operation • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. • You may hear the thermostat click when the compressor cycles on and off. • Water will collect in the base pan during high humidity or on rai
Summary of the content on the page No. 19
ENGLISH FRIEDRICH AIR CONDITIONING CO. Post Office Box 1540 • San Antonio, Texas 78295-1540 (210) 357-4400 • FAX (210) 357-4490 ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible un
Summary of the content on the page No. 20
FRANÇAIS Manuel d'utilisation et d'installation de votre climatiseur de pièce 0 F Fan hr Speed Auto Swing Money Fan Cool Saver Only ® Dry Temp Timer Power 0n /0ff Mode CP Line CP08 115 Volts CP06 Enregistrement de votre climatiseur de pièce Vous trouverez l'information concernant l'appareil sur la plaque signalétique située sur le côté de l'appareil, près du panneau de commande. Veuillez remplir et poster la carte d'enregistrement fournie avec l'appareil ou enregistrez-vous en ligne à www.friedr