CANADIAN PROPANE CONSTRUCTION FORCED AIR HEATER
OWNER’S MANUAL
MODEL RCLP30
30,000 BTU/HR
IMPORTANT: Read and understand this manual before
assembling, starting or servicing heater. Improper use
of heater can cause serious injury. Keep this manual for
future reference.
GENERAL HAZARD WARNING:
Failure to comply with the precautions and instructions
provided with this heater, can result in death, serious
bodily injury and property loss or damage from hazards
of fire, explosion, burn, asphyxi
Summary of the content on the page No. 2
Propane Gas: Propane gas is odorless. An odor- SAFETY INFORMATION making agent is added to propane gas. The odor helps you detect a propane gas leak. However, the WARNING: This product odor added to propane gas may fade. Propane gas contains and/or generates may be present even though no odor exists. chemicals known to the State Make certain you read and understand all warn- of California to cause cancer or ings. Keep this manual for reference. It is your birth defects or other reproduc
Summary of the content on the page No. 3
SAFETY INFORMATION PRODUCT Continued IDENTIFICATION 14. Keep heater at least 6 feet (1.8 m) from pro- Hot Air Outlet Shell (Front) pane tank(s). Do not point heater at propane Handle tank(s) within 20 feet (6 m). 15. Keep propane tank(s) below 100° F (38˚ C). Motor 16. Check heater for damage before each use. Do not use a damaged heater. 17. Check hose before each use of heater. If highly worn or cut, replace before using heater. 18. Do not alter heater. Keep heater in its original Piezo I
Summary of the content on the page No. 4
ASSEMBLY PROPANE SUPPLY 1. Remove screw from top of fan guard. Discard Propane gas and propane tank(s) are to be fur- screw. nished by the user. 2. Insert nut clip (provided with handle) with Use this heater only with a propane vapor flat side facing up through slot in top of shell. withdrawal supply system. See Chapter 5 of the Align holes in nut clip with screw hole behind Standard for Storage and Handling of Liquefied slot in top of shell. (see Figure 4). Petroleum Gas, ANSI/NFPA 58 and/or C
Summary of the content on the page No. 5
3. Connect hose to valve inlet. Tighten firmly INSTALLATION using a wrench (see Figure 7). IMPOR T ANT : Extra hose or piping may be WARNING: Review and un- used if needed. Install extra hose or piping derstand the warnings in the between hose/regulator assembly and propane Safety Information section, page tank. You must use the regulator supplied with 2. They are needed to safely op- heater. erate this heater. Follow all local 4. Open propane supply valve on propane tank(s) codes when
Summary of the content on the page No. 6
TO RESTART HEATER OPERATION 1. Wait five minutes after stopping heater. Continued 2. Repeat steps under To Start Heater. WARNING: Be sure motor STORAGE and fan are running before pushing in automatic control CAUTION: Disconnect heater valve button. Flames could flash from propane supply tank(s). outside heater if motor and fan 1. Store propane tank(s) in safe manner. See are not running. Chapter 5 of Standard for Storage and Han- dling of Liquefied Petroleum Gases, ANSI/ 6. Push in and hol
Summary of the content on the page No. 7
TROUBLESHOOTING WARNING: Never service heater while it is plugged in, connected to propane supply, operating or hot. Severe burns and electrical shock can occur. OBSERVED FAULT POSSIBLE CAUSE REMEDY Fan does not turn when heater is 1. No electrical power to heater 1. Check voltage to electrical plugged in outlet. If voltage is good, check heater power cord for breaks 2. Fan hitting inside of heater 2. Adjust motor/fan mount to shell keep fan from hitting inside of heater shell. Bend fan
Summary of the content on the page No. 8
SERVICE PROCEDURES Setscrew WARNING: Never service heater while it is plugged in, connected to propane supply, operating or hot. Severe burns and electrical shock can occur. ELECTRICAL SYSTEM Figure 10 - Setscrew Location The entire electrical system for this heater is con- tained within the motor. If any part of the electrical system is damaged, you must replace motor. MOTOR 1. Remove three screws that attach fan guard to heater shell. 2. Remove motor and fan guard from heater shell (se
Summary of the content on the page No. 9
8. Test for spark. Push piezo ignitor button and SERVICE PROCEDURES watch for spark between ignitor electrode and Continued target plate. IGNITOR 9. Place motor and fan guard into rear of heater 1. Remove motor and fan guard from heater (see shell (see Motor, page 8, steps 8 and 9). Motor, page 8, steps 1 and 2). 2. Remove black ignitor wire from piezo ignitor. Ignitor Access ignitor wire through underside of Electrode heater base (see Figure 13). Push wire up through notch in filler pane
Summary of the content on the page No. 10
ILLUSTRATED PARTS BREAKDOWN MODEL RCLP30 1 16 6 15 13 5 7 2 8 23 14 18 19 4 20 12 9 10 22 21 1 1 3 17 10 www.desatech.com 104787-01D
Summary of the content on the page No. 11
PARTS LIST MODEL RCLP30 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts, below. KEY NO. PART NO. DESCRIPTION QTY 1 ** Combustion Chamber 1 2 ** Unichassis 1 3 M11143-1 Bushing, Strain Relief 1 4 M11084-27 Screw 2 5 099237-01 Thermocouple Nut 2 6 103894-01 Target Bracket Kit 1 7 104784-01 Electrode Ignitor 1 8 M11084-38 Hex Tap Screw, #8-18 x 3/8" 1 9 101478-02 Fan 1 10 104156-01 Motor Assembly 1 11 103863-01
Summary of the content on the page No. 12
WARRANTY AND REPAIR SERVICE KEEP THIS WARRANTY Model Serial No. Date of Purchase LIMITED WARRANTY DESA Industries warrants this product and any parts thereof, to be free from defects in materials and workmanship for one (1) year from the date of first purchase when operated and maintained in accordance with instructions. This warranty is extended only to the original retail purchaser, when proof of purchase is provided. This warranty covers only the cost of parts and labor required to restore t
Summary of the content on the page No. 13
APPAREIL DE CHAUFFAGE À AIR FORCÉ DE CHANTIER AU GAZ PROPANE POUR LE CANADA MANUEL D'UTILISATION MODÈLE RCLP30 30 000 BTU/H IMPORTANT : lisez et comprenez ce manuel avant d'assembler, d'allumer ou de réparer l'appareil de chauffage. Une mauvaise utilisation de l'appareil de chauffage peut causer des blessures graves. Conservez ce manuel pour référence future. AVERTISSEMENT DE RISQUE GÉNÉRAL : Tout manquement aux précautions et aux instructions four- nies avec cet appareil de chauffage peut
Summary of the content on the page No. 14
Nous ne pouvons pas prévoir toutes les utilisations INFORMATION RELATIVE possibles de nos appareils de chauffage. Vérifiez À LA SÉCURITÉ auprès de votre responsable local de la sécurité- incendie si vous avez des questions relatives à AVERTISSEMENT : cet ap- l'utilisation de l'appareil de chauffage. pareil contient ou produit des Empoisonnement au monoxyde de carbone : cer- produits chimiques déterminés taines personnes sont plus sensibles au monoxyde de par l'État de Californie comme car
Summary of the content on the page No. 15
26. Ne déplacez, ne manipulez et ne réparez jamais INFORMATION RELATIVE un appareil de chauffage chaud, en fonctionne- À LA SÉCURITÉ Suite ment ou branché. Vous risqueriez de vous brûler 9. Usage à l'intérieur seulement. N'utilisez pas gravement. Attendez 15 minutes après avoir éteint l'appareil de chauffage à l'extérieur. l'appareil de chauffage. 10. N'utilisez pas l'appareil de chauffage dans un édifice 27. Pour ne pas vous blesser, portez des gants lorsque habité ou dans des endroits où
Summary of the content on the page No. 16
3. Placez la poignée sur le trou et la pince-écrou. THÉORIE DE Insérez deux vis (fournies avec la poignée) FONCTIONNEMENT à travers la poignée et serrez.Assurez-vous Système d'approvisionnement en carburant : que la vis arrière passe à travers l'habillage lʼensemble flexible/détendeur se branche sur et rejoint la grille du ventilateur. Resserrez la bouteille de propane pour alimenter lʼappareil. les vis fermement. Système d'admission d'air : le moteur fait tourner Écrou à le ventilateu
Summary of the content on the page No. 17
APPROVISIONNEMENT AVERTISSEMENT : testez EN PROPANE toutes les conduites de gaz et Le gaz propane et les réservoirs de propane doivent les connexions pour détecter être fournis par l'utilisateur. les fuites après l'installation ou N'utilisez cet appareil de chauffage qu'avec un la révision. N'utilisez jamais de système d'approvisionnement à élimination de flamme nue pour rechercher une vapeurs de propane. Consultez le chapitre 5 de la Norme pour l'emmagasinage et la manipulation fuit
Summary of the content on the page No. 18
à trois broches. La rallonge électrique doit INSTALLATION mesurer au moins 2 m (6 pi). Elle doit porter Suite l'homologation UL. 4. Ouvrez lentement la vanne d'approvision- Exigences des dimensions de la rallonge nement en propane du ou des réservoirs de électrique propane. Remarque : si on ne l'ouvre pas Jusqu'à 15 m (50 pi), employez un cordon de lentement, la vanne de débit du réservoir de calibre 18 AWG. propane peut couper le gaz. Dans ce cas, fer- Entre 16 et 30 m (51 et 100 pi),
Summary of the content on the page No. 19
2. Replacez les bouchons en plastique sur les FONCTIONNEMENT raccords en laiton d'entrée et de l'assemblage Suite du tuyau et du détendeur. Remarque: Si lʼappareil ne sʼallume pas, 3. Entreposez l'appareil de chauffage dans un il se peut que le flexible contienne de lʼair. endroit sec, propre et sans danger. N'entrepo- Dans ce cas, maintenir le bouton de vanne de sez pas l'assemblage du tuyau et du détendeur commande automatique enfoncé pendant 20 à l'intérieur de la chambre de combustion
Summary of the content on the page No. 20
DÉPANNAGE AVERTISSEMENT : ne réparez jamais l'appareil de chauffage lorsqu'il est branché, connecté à l'approvisionnement en gaz, en marche ou brûlant. Des brûlures et des chocs électriques graves peuvent se produire. PROBLÈME OBSERVÉ CAUSE POSSIBLE REMEDY Le ventilateur ne tourne pas 1. Aucun courant ne se rend à 1. Vérifiez la tension de la prise de quand l'appareil de chauffage l'appareil de chauffage courant. Si la tension est correcte, est branché inspectez le cordon électrique de l'ap