DENSO CORPORATION MOVINCOOL OFFICE PRO 18 user manual

User manual for the device DENSO CORPORATION MOVINCOOL OFFICE PRO 18

Device: DENSO CORPORATION MOVINCOOL OFFICE PRO 18
Category: Air Conditioner
Manufacturer: DENSO CORPORATION
Size: 1.18 MB
Added : 10/11/2013
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for DENSO CORPORATION MOVINCOOL OFFICE PRO 18. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with DENSO CORPORATION MOVINCOOL OFFICE PRO 18.

For your convenience

If looking through the DENSO CORPORATION MOVINCOOL OFFICE PRO 18 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual DENSO CORPORATION MOVINCOOL OFFICE PRO 18 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual DENSO CORPORATION MOVINCOOL OFFICE PRO 18 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
DENSO CORPORATION MOVINCOOL OFFICE PRO 18 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual DENSO CORPORATION MOVINCOOL OFFICE PRO 18 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to DENSO CORPORATION MOVINCOOL OFFICE PRO 18. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OPERATION MANUAL
OFFICE PRO 12 / OFFICE PRO 18 / OFFICE PRO 24
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT
INSTALLATION AND USAGE AND READ ALL SAFEGUARDS
SECCIÒN EN ESPAÑOL
SECTION EN FRANÇAIS
AVAILABLE AT WWW.MOVINCOOL.COM

Summary of the content on the page No. 2

© 2007 DENSO SALES CALIFORNIA, INC. All rights reserved. This book may not be reproduced or copied, in whole or in part, without the written permission of the publisher. DENSO SALES CALIFORNIA, INC. reserves the right to make changes without prior notice. MovinCool is a registered trademark of DENSO Corporation.

Summary of the content on the page No. 3

OPERATION MANUAL OFFICE PRO 12 / OFFICE PRO 18 / OFFICE PRO 24

Summary of the content on the page No. 4

Table of Contents ................................................................................. FOREWORD 5 ............................................................... Definition of Terms 5 ........................................ 6 GENERAL WARNINGS & CAUTIONS ................................................................................ Inventory 7 ............................................................................ 8 INSTALLATION .........................

Summary of the content on the page No. 5

FOREWORD Congratulations on purchasing the MovinCool portable air conditioner. This manual explains how to install and operate the MovinCool Office Pro12, Office Pro18, and Office Pro24 portable air conditioning units. Please read this operation manual thoroughly to familiarize yourself with the features of the unit and to ensure years of reliable operation. You may also find it useful to keep this operation manual on hand for reference. Components and/or procedures are subject to change

Summary of the content on the page No. 6

GENERAL WARNINGS & CAUTIONS 1) All electrical work, if necessary, should only be performed by qualified electrical personnel. Repair to electrical components by non-certified technicians may result in personal injury and/or damage to the unit. All electrical components replaced must be genuine MovinCool parts, purchased from an authorized reseller. 2) The proper electrical outlet for MovinCool units must be equipped with a UL approved circuit breaker. 3) Because of

Summary of the content on the page No. 7

MOVINCOOL MOVINCOOL INVENTORY After unpacking your MovinCool unit, please check to make sure you have the following items : 1) Office Pro 12 or Office pro 18 or Office Pro 24 MovinCool Unit (1) 2) Operation Manual/Product Registration (1) NOTE : If any of these items were not included in the box or appear damaged, please contact your MovinCool reseller for replacement. O O OFFICE PRO 24 MOVINCOOL UNIT OFFICE PRO 12 MOVINCOOL UNIT OFFICE PRO 18 MOVINCOOL UNIT OPERATION MANUAL/ PRODUCT REG

Summary of the content on the page No. 8

INSTALLATION Choosing an Installation Site ! CAUTION : Following are some precautions to consider before choosing your installation site. Please review carefully as improper installation may result in personal injury or damage to the unit. 1) Do not use the unit in areas where leakage of flammable gas may occur. 2) Do not use the unit in areas where it will be exposed to rain or water. 3) Do not use the unit in an atmosphere of excessively corrosive gas or vapor. 4) Do not use in ar

Summary of the content on the page No. 9

MOVINCOOL INSTALLATION(cont.) Moving the Unit Unlock the casters and push the MovinCool unit using the side handles to a flat, level surface and set the casters back to the LOCKED position. Right Side Handle Left Side Handle O UNLOCKED LOCKED 9

Summary of the content on the page No. 10

INSTALLATION (cont.) Plugging in the Unit 1) Check the prong and surface of the power cord plug for dust/dirt. If dust and/or dirt are present, wipe off with a clean, dry cloth. 2) Check the power cord, plug and prong for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller for repair. ! WARNING: 1) If the power cord or plug is damaged, repair should only be performed by qualified electrical personnel. 2) Do not connect/disconnec

Summary of the content on the page No. 11

INSTALLATION (cont.) Warning Signal Connection (Output Signal terminal L+ and L-) The controller is equipped with a warning signal output relay type (Form C, normal open dry contact) which can be used to monitor the failure condition. Relay contactor (not connector) is closed when the following condition has occurred : a. Tank Full b. Temperature sensor fails c. High pressure switch error (model OP24 only) The relay output contactor is rated 2A at 30VDC or 2A at 30VAC (resistive load) and it

Summary of the content on the page No. 12

INSTALLATION (cont.) LCDI Power Cord Instruction ! WARNING The LCDI device is non-serviceable device. Attempting to open the device may expose the user to hazardous of electric shock, and could void warranties of this product. Manufacturer’s reliability is limited to the replacement of the device. ! CAUTION 1. Read the attention print on the device for proper use and handling of this device. 2. This device is used for monitoring leakage current. 3. Do not immerse in water. 4.

Summary of the content on the page No. 13

FEATURES For all models: 1) A digital electronic control panel, which allows the user to control the unit’s operation easily. 2) Dual fan speeds (either HIGH or LOW) in both COOL and Fan Only modes. 3) Digital LCD display with blue backlight that indicates: a. Clock with day and time. b. Room Temperature and Set Point Temperature (either Fahrenheit or Celsius). c. Fan Speed Status d. Cool Mode Status e. Program Start time and Stop time f. Program Run and Stop g. Status Codes

Summary of the content on the page No. 14

OPERATION Control Panel Before operating the unit, it is important to familiarize yourself with the basic controls located on the control panel. PROGRAM MO TU WE TH FR SA SU AM START 7 PROGRAM STOP RUN/ PM ON CLOCK STOP LOCKED FF HI FAN C C LO PROGRAMMING ON SET TEMP COOL OFF ROOM TEMP 6 SET PROG TANK FULL 8 FAN MODE 5 2 SET HI/LO CLOCK SET TEMP COOL MODE 1 4 ON/OFF ENTER 3 1) COOL Mode Button Activates/deactivates the COOL mode/turns

Summary of the content on the page No. 15

OPERATION (cont.) Control Panel (Cont.) LCD Indicators 9 11 14 12 15 13 16 19 10 17 18 9) MO...SU Illuminates to indicate selected day of the week Temperature displayed in either Fahrenheit 10) °C or °F or Celsius (See Note) Illuminates to indicate AM or PM time of day. 11) AM/PM Blinking during program editing mode. 12) PROGRAM 13) PROGRAM ON Illuminates to indicate program is running. 14) START Illuminates to indicate program start time. 15) STOP Illuminates to indicate program stop time

Summary of the content on the page No. 16

OPERATION (cont.) Set Clock Prior to operating the Office Pro 12, 18, or 24 users should set the clock of the controller to the correct time as shown in the following steps : 1) Press and hold the SET CLOCK button for 3 seconds or until beep. PROGRAM MO TU WE TH FR SA SU AM START (LCD will indicate blinking “CLOCK” PROGRAM STOP RUN/ PM ON CLOCK STOP LOCKED and blinking “Day of the week ”) FF HI C FAN C LO 2) Press SET TEMP buttons to PROGRAMMING ON SET TEMP COOL ROOM TEMP OFF

Summary of the content on the page No. 17

OPERATION (cont.) How to Set a Program SET START TIME PROGRAM MO TU WE TH FR SA SU AM 1) Press and hold the “SET PROG” START PROGRAM STOP RUN/ PM ON CLOCK STOP button for 3 seconds or until beep. LOCKED HI FF FAN C C LO ON SET TEMP PROGRAMMING 2) Press “SET TEMP” buttons to select COOL OFF ROOM TEMP SET Step 1 & 18 day of the week. PROG TANK FULL 3) Press “ENTER” button. FAN MODE SET HI/LO CLOCK 4) Press “SET TEMP” buttons to select SET TEMP COOL MODE Step 2 to 17 de

Summary of the content on the page No. 18

OPERATION (cont.) How to View and Delete Program 1) Press and hold the SET PROG button for 3 seconds or until beep. 2) To view edited program - While pressing and holding the SET PROG button, press SET TEMP ( / ) to scroll program sequence. 3) To delete a program - Press ENTER and SET PROG buttons once simultaneously. 4) To delete multiple program - Press and hold ENTER and SET PROG buttons simultaneously. How to Run and Stop Program 1) Press RUN/STOP button to activate

Summary of the content on the page No. 19

OPERATION (cont.) Operating Modes The Office Pro 12, Office Pro 18, and Office Pro 24 can be operated in two modes, Fan Only and COOL. When in Fan Only mode, the unit circulates the surrounding air. When in COOL mode, the compressor is operational and cool air is circulated. 1) COOL Mode Once the compressor has been disengaged for more than 120 seconds, the unit will operate in Fan Only mode for approximately 5 seconds before the compressor re-engages. (Time delay setting is around 120 se

Summary of the content on the page No. 20

OPERATION (cont.) Empty the Drain Tank During COOL mode, condensate will accumulate in the drain tank. When the drain tank becomes full, the FULL TANK LED will flash and the LCD displays “Tank FL” and the ALARM signal output is turned ON and the unit will shut off automatically * . NOTE : If you want to empty the drain tank, while the unit is in operation, press the COOL ON/OFF button to turn the unit off. * Not available for OP 12 model 1) Open the drain tank door. 2) Pull the drain tank f


Alternative user manuals
# User manual Category Download
1 DENSO CORPORATION CLASSIC PLUS 26 User manual Air Conditioner 5
2 DENSO CORPORATION 18 User manual Air Conditioner 2
3 DENSO CORPORATION OFFICE PRO 12 User manual Air Conditioner 0
4 DENSO CORPORATION MOVINCOOL OFFICE PRO 24 User manual Air Conditioner 2
5 DENSO CORPORATION Ofice Pro 36 User manual Air Conditioner 3
6 DENSO CORPORATION OFFICE PRO 24 User manual Air Conditioner 2
7 DENSO CORPORATION MOVINCOOL OFFICE PRO 12 User manual Air Conditioner 1
8 Sony SU-PW2 User manual Air Conditioner 12
9 Sony CV-P12PX User manual Air Conditioner 3
10 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
11 Sony VGN-BX500 User manual Air Conditioner 1
12 Philips 190S5 User manual Air Conditioner 21
13 Philips Comfort-Cire AMC 45 User manual Air Conditioner 7
14 Philips Comfort-Cire AMC 30 User manual Air Conditioner 2
15 Philips CS-E15DB4EW User manual Air Conditioner 4