Summary of the content on the page No. 1
OPERATION MANUAL
OFFICE PRO 36
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT IN-
STALLATION AND USAGE, AND READ ALL SAFEGUARDS.
DENSO SALES CALIFORNIA, INC.
3900 Via Oro Avenue
Long Beach CA 90810-1868
800-264-9573 / 310-834-6352
www.movincool.com
U
C L US LISTED
First Issue: March 2005
DSCA P/N: LA484007-1810 Printed in the U.S.A.
Summary of the content on the page No. 2
LIMITED WARRANTY DENSO SALES CALIFORNIA, INC. (“DENSO”) warrants its MOVINCOOL Products only to the extent stated in its official written warranties. Unless otherwise specifi cally provided in writing by DENSO, DENSO warrants to end- user that the Products shall be free of defects in materials or workmanship and will function in accordance with DENSO’s published specifi cations under ordinary intended use and service for a period of twelve (12) months after delivery to the end-user; provided,
Summary of the content on the page No. 3
TABLE OF CONTENTS FOREWORD ............................................................................................ 1 Defi nition of Terms ........................................................................... 1 GENERAL WARNINGS & CAUTIONS .................................................... 1 INVENTOR INVENTOR INVENTORY Y Y ............................................................................................. ......................................................................
Summary of the content on the page No. 4
FOREWORD Congratulations on purchasing the MovinCool portable air conditioner. This manual explains how to assemble, install and operate the MovinCool Offi ce Pro 36 portable air conditioning unit. Please read this operation manual thoroughly to familiarize yourself with the features of the unit and to ensure years of reliable operation. You may also fi nd it useful to keep this operation manual on hand for reference. Components and/or procedures are subject to change without prior notice. De
Summary of the content on the page No. 5
3 6 INVENTORY After unpacking your MovinCool unit, please check to make sure you have the following items: • Offi ce Pro 36 MovinCool Unit (1) • Operation Manual/Warranty Card (1) NOTE: If any of these items were not included in the box or appear damaged, please contact your MovinCool reseller for replacement. OPERATION MANUAL/ WARRANTY CARD INSTALLATION Choosing an Installation Site CAUTION: Following are some precautions to consider before choosing your in- stallation site. Please review car
Summary of the content on the page No. 6
Moving the Unit Unlock the casters and push the MovinCool unit, using the side handles, to a fl at, level surface and set the casters back to the LOCKED position. FRONT AND BACK HANDLES UNLOCKED LOCKED Plugging in the Unit • Check the prongs and surface of the power cord plug for dust/dirt. If dust and/or dirt are present, wipe off with a clean, dry cloth. • Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller
Summary of the content on the page No. 7
FEATURES OP36 Features • An electronic control panel which allows the user to control the unit’s operation easily. • Dual fan speeds (either High or Low) in both COOL and Fan Only modes. • A digital display that indicates the Temperature SET POINT (either Fahrenheit or Celsius) in which the COOL Mode will operate. This is also the temperature the unit will try to maintain. The Temperature SET POINT can be adjusted by the SET TEMP buttons (▼/▲). (65ºF-95ºF) • A condensate drain TANK FULL in
Summary of the content on the page No. 8
7. Temperature Scale LED - Illuminates to indicate 7 8 the current temperatures being displayed are either in °C or °F; also used to display the clock when programming. SET TEMP CLOCK/TIMER 8. AM/PM LED - Illuminates to indicate AM or PM HRS MIN 12 time of day. FAN ON/OFF 9. Program RUN Button - Activates/deactivates a START TIME program. END TIME 11 SET CLOCK 10. Program SET Button - Allows the user to pro- 9 SET RUN gram the unit or check the current program. 10 COOL ON/OFF PROGRAM 1
Summary of the content on the page No. 9
How to Set a Program ➀ Setting a START TIME Press the Program SET button. The Program SET button and START TIME LEDs will illuminate. Press the HRS and MIN buttons to set the START TIME. ➁ Setting an END TIME Press the Program SET button until the END TIME LED illuminates. Press the HRS and MIN buttons to set the END TIME. ➂ Setting the CLOCK TIME Press the Program SET button until the SET CLOCK ET CLOCK ET CLOCK LED illuminates. Pr LED illuminates. Press the HRS ess the HRS and MIN but
Summary of the content on the page No. 10
Operating Modes Offi ce Pro 36 operates in 2 modes, FAN Only and COOL. When in FAN Only mode, the unit circulates the surrounding air. When in COOL mode, the compressor is operational and cool air is circulated. • COOL Mode Offi ce Pro 36 will operate in FAN Only mode for approximately 120 seconds before the compressor engages. (Time delay setting is 120 ±15 seconds.) • Temperature Control The room temperature thermistor allows the unit to switch automatically between COOL and FAN Only mode
Summary of the content on the page No. 11
Drain Pump (Optional) A drain pump allows continuous operation and eliminates the need for drain tanks. • When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and discharges the water. A B • When the water level drops below level (B), the drain pump will stop. NOTE: • If for any reason the water level exceeds that of level (A) in the pump reservoir, an overfl ow Drain Switch will stop the compressor operation. • If the Fan Mode Control DIP Switch (se
Summary of the content on the page No. 12
Cleaning Method ➀ Remove dust from the element with a vacuum cleaner, or rinse in cold or lukewarm water. If the element is extremely dirty, wash FIL TER with a neutral detergent. ➁ After the element has been cleaned, rinse with clean running water, allow to dry, then reinstall. In-Season/Off-Season Inspection & Maintenance ■ In-Season ➀ Check the prongs and surface of the power cord plug for dust and/or dirt. If dust and/or dirt are present, wipe off with a clean, dry cloth. ➁ Check the pow
Summary of the content on the page No. 13
Check the following points before calling a qualifi ed technician. SYMPTOM SYMPTOM SYMPTOM POSSIBLE CAUSE POSSIBLE CAUSE POSSIBLE CAUSE REMEDY REMEDY REMEDY Unit does not operate ➀ Gr Ground fault br ound fault breaker tripped eaker tripped Reset br Reset breaker eaker ➁ Drain tank is full Drain tank is full Empty the drain tank Empty the drain tank ((FULL T FULL T FULL TANK ANK ANK LED will be LED will be fl fl ashing) ashing) Insuffi cient cooling ➀ Dirty/blocked air fi Dirty/block
Summary of the content on the page No. 14
TECHNICAL SPECIFICATIONS ITEM/FEA ITEM/FEATURES TURES OFFICE PRO 36 OFFICE PRO 36 Rating Conditions dry bulb dry bulb 95º F (35º C) 95º F (35º C) wet bulb wet bulb 83º F (28.2º C) 83º F (28.2º C) humidity humidity 60% 60% Specifi cations power fr power frequency equency 60Hz 60Hz line voltage line voltage single phase 208/230V single phase 208/230V power consumption power consumption 4.4 Kw 4.4 Kw curr current consumption ent consumption 19.7 Amps 19.7 Amps power factor
Summary of the content on the page No. 15
LIMITED WARRANTY DENSO SALES CALIFORNIA, INC. (“DENSO”) warrants its MOVINCOOL Products only to the extent stated in its official written warranties. Unless otherwise specifi cally provided in writing by DENSO, DENSO warrants to end- user that the Products shall be free of defects in materials or workmanship and will function in accordance with DENSO’s published specifi cations under ordinary intended use and service for a period of twelve (12) months after delivery to the end-user; provided,
Summary of the content on the page No. 16
OPERATION MANUAL OFFICE PRO 36 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT IN- STALLATION AND USAGE, AND READ ALL SAFEGUARDS. DENSO SALES CALIFORNIA, INC. 3900 Via Oro Avenue Long Beach CA 90810-1868 800-264-9573 / 310-834-6352 www.movincool.com U C L US LISTED First Issue: March 2005 DSCA P/N: LA484007-1810 Printed in the U.S.A.