DeLonghi PAC 210 U user manual

User manual for the device DeLonghi PAC 210 U

Device: DeLonghi PAC 210 U
Category: Air Conditioner
Manufacturer: DeLonghi
Size: 0.57 MB
Added : 10/11/2013
Number of pages: 17
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for DeLonghi PAC 210 U. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with DeLonghi PAC 210 U.

For your convenience

If looking through the DeLonghi PAC 210 U user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual DeLonghi PAC 210 U on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual DeLonghi PAC 210 U to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
DeLonghi PAC 210 U User manual - Online PDF
Advertisement
« Page 1 of 17 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual DeLonghi PAC 210 U but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to DeLonghi PAC 210 U. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OWNERS’ MANUAL
PAC 210 U Portable Windowless
Air-Conditioner
1

Summary of the content on the page No. 2

IMPORTANT INFORMATION When using electrical appliances, basic safety precautions should always be followed, including the following: - Read all instructions. - To protect against fire, electrical shock and personal injury, do not immerse cord, plug or appliance in water or other liquid. - Close supervision is necessary when any appliance is used by or near children. - Do not operate with a damaged cord or plug, or after the appliance malfunctions, or has been damaged in any manner. Return the ap

Summary of the content on the page No. 3

Dear user, We thank you for purchasing the Pinguino air-conditioner and congratulate you on your wise choice. For optimal results please read this manual carefully before installing or operating. We know that the Pinguino will maintain your environment pleasingly comfortable at all times. With best wishes De Longhi S.p.A. If you have any questions about the operation or service of your Pinguino, please call our toll-free service number 1-800-322-3848. or visit our internet site: www.delonghi

Summary of the content on the page No. 4

SPECIFICATIONS Power supply voltage V see rating label Frequency Hz 60 Cooling capacity: (*) see rating label Fan speeds 2 Max. air flow capacity 360 cu.m/h Dehumidification quotient (*) see rating label 1 31 22 / (560) Dimensions: width in. (mm) 30 (735) height in. (mm) 9 16 15 / (390) depth in. (mm) Net weight lb. (kg) 97 (44) *Data according to pending standard testing procedures subject to review by the U.S. Dept. of Energy. A HE (High efficiency) system with low energy consumption has been

Summary of the content on the page No. 5

ILLUSTRATED MAIN FEATURES LIST Air outlet grid Timer cover (to adjust the timer slide cover sideways) Castor Castor stops Water collecting tray Air filter Air intake grid Exhaust hose Power cable comp. Manually resettable red button Water collecting tray drainage tube 5

Summary of the content on the page No. 6

ILLUSTRATED ACCESSORY LIST Table 1 DESCRIPTION SUPPLIED Exhaust hose 1 Stopper + flange 1 Caster stop 2 Window nozzle 1 Adjustable window bracket 1 Suction disc 2 ACCESSORY CHECK Check that all parts listed in Table 1 are included. 6

Summary of the content on the page No. 7

PERMANENT INSTALLATION The Pinguino accessories include two sets of flanges and stoppers, to be mounted in different locations (two different rooms). Once installed, these vents (flanges) are the only items needed for using Pinguino. fig. 1 Permanent installation outlet holes must be in an exterior wall and opening diameter should not 1 exceed 3” /2. INSIDE OUTSIDE INSIDE OUTSIDE A1 A2 fig. 2 fig. 3 in a window pane through the wooden base- section of a door or window INSIDE OUTSIDE 1”

Summary of the content on the page No. 8

30 cm TEMPORARY INSTALLATION Note: In both cases (permanent and temporary installations) make sure that the Pinguino is positioned on level ground. If necessary use the two caster stops for the front casters This installation makes it easy Suction discs may be used to Pinguino is equipped with an to use Pinguino in any room, keep window or door closed. adjustable window bracket. If provided there is a window or you have a sash window, a door: it allows you to use the place the bracket on the Pin

Summary of the content on the page No. 9

ELECTRICAL CONNECTION Check that the power supply voltage is 115 V ~ 60 Hz. Important: if you need to use and extension cord, please be sure to use a heavy duty extension cord (minimum 14 gauge). Before connecting the Pinguino to power supply, make sure that all switches on the front control panel are in the OFF position. Connect power cord found in storage compartment at rear of the fig. 9 Pinguino. FINAL CHECK In order to obtain the maximum performance from your air-conditioner make sure that:

Summary of the content on the page No. 10

4 4 9 9 10 DESCRIPTION OF PINGUINO PAC 210 U CONTROLS ON/OFF button ON/OFF pilot light A BC “Alarm” pilot light Timer ON/OFF pilot light Timer ON/OFF Selecting fan Timer notches Thermostat button speed button SETTING THE TIMER PROGRAMMED MODE The programmer/timer, like all clocks, must be 1) Release B timer button. set to the exact time. If for example it is 4.00 2) Set the operating times by pushing out the p.m., turn the dial in a clockwise direction notches on the dial corresponding to the (f

Summary of the content on the page No. 11

HOW TO START UP THE CONDITIONER (see control panel on the previous page) Plug the appliance into the mains. Select the “programmed” or “non programmed” mode (see previous page) Select the fan speed required pressing “Fan speed” key C. AIR-CONDITIONING Key A ON/OFF (conditioning) must be released Turn the thermostat to Max. Cold. Press key A (ON/OFF). ON/OFF signal lamp (conditioning) will come on. The appliance comes on. If not, refer to page 14. To switch off the appliance, press key A (ON/OFF

Summary of the content on the page No. 12

MAINTENANCE PRECAUTIONS fig. 14 fig. 15 During cleaning and normal maintenance operations Under no circumstances should appliance be remember to disconnect plug. washed with running water. Damage could be caused to the electrical circuit. CLEANING OF EXTERNAL HOUSING Use only mild soap and water. Do not use chemical cleaners. QQ¢¢ QQ¢¢ fig. 16 Clean with a damp cloth and dry thoroughly fig. 17 with a clean dry cloth. CONTROLS AT THE BEGINNING OF THE SEASON Carefully follow Check for any def

Summary of the content on the page No. 13

AIR FILTER CLEANING Maintenance of air filter Removal and replacement of air filter A clogged air filter reduces the quantity of Gently pull filter upwards. circulating air and the efficiency of the Push down to replace. appliance. Clean filter every week using a vacuum cleaner. fig. 19 fig. 20 Remove dust with a Rinse with running vacuum cleaner water fig. 21 Cleaning procedure To remove dust deposited on filter, use a vacuum cleaner. If it is very dirty, soak in lukewarm water and rinse thoro

Summary of the content on the page No. 14

TROUBLESHOOTING SYMPTOMS CAUSE SOLUTION The Pinguino does not - power failure - plug is disconnected - insert plug function: - ON/OFF switch is off - switch on - Timer key is in STOP position - release the TIMER key The Pinguino does not function - function fault warning - exhaust hose blocked - Check for obstruction of air light is on (page. 10 - outlet vent - exhaust hose twisted or bent - eliminate irregularities “Alarm” light) - ventilation holes on the rear of - remove obstacles to allow Af

Summary of the content on the page No. 15

FOR UNITED STATES ONLY: LIMITED WARRANTY We warrant each DeLonghi AIR-CONDITIONER to be free from defects in material and workmanship. Our obligation under this warranty is to provide one year parts and labor free from purchase date, with an additional four (4) years on any part of the sealed system consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing. This warranty shall apply only if the AIR-CONDITIONER is used in accordance with the factory directions w

Summary of the content on the page No. 16

16

Summary of the content on the page No. 17


Alternative user manuals
# User manual Category Download
1 DeLonghi CT300 User manual Air Conditioner 965
2 DeLonghi PAC70 ECO User manual Air Conditioner 612
3 DeLonghi PAC N130HPE User manual Air Conditioner 132
4 DeLonghi WE130 User manual Air Conditioner 101
5 DeLonghi WE 110 User manual Air Conditioner 199
6 DeLonghi PAC60 User manual Air Conditioner 387
7 DeLonghi PAC 02 User manual Air Conditioner 178
8 DeLonghi WE125 User manual Air Conditioner 380
9 DeLonghi FX400ECO User manual Air Conditioner 93
10 DeLonghi CT300H User manual Air Conditioner 75
11 DeLonghi KW 85 User manual Air Conditioner 10
12 DeLonghi PAC 400 User manual Air Conditioner 34
13 DeLonghi PAC 290 U User manual Air Conditioner 35
14 DeLonghi PAC W130E User manual Air Conditioner 208
15 DeLonghi PAC-A130HPE User manual Air Conditioner 144
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21