Summary of the content on the page No. 1
OWNERS’ MANUAL
PAC 210 U Portable Windowless
Air-Conditioner
1
Summary of the content on the page No. 2
IMPORTANT INFORMATION When using electrical appliances, basic safety precautions should always be followed, including the following: - Read all instructions. - To protect against fire, electrical shock and personal injury, do not immerse cord, plug or appliance in water or other liquid. - Close supervision is necessary when any appliance is used by or near children. - Do not operate with a damaged cord or plug, or after the appliance malfunctions, or has been damaged in any manner. Return the ap
Summary of the content on the page No. 3
Dear user, We thank you for purchasing the Pinguino air-conditioner and congratulate you on your wise choice. For optimal results please read this manual carefully before installing or operating. We know that the Pinguino will maintain your environment pleasingly comfortable at all times. With best wishes De Longhi S.p.A. If you have any questions about the operation or service of your Pinguino, please call our toll-free service number 1-800-322-3848. or visit our internet site: www.delonghi
Summary of the content on the page No. 4
SPECIFICATIONS Power supply voltage V see rating label Frequency Hz 60 Cooling capacity: (*) see rating label Fan speeds 2 Max. air flow capacity 360 cu.m/h Dehumidification quotient (*) see rating label 1 31 22 / (560) Dimensions: width in. (mm) 30 (735) height in. (mm) 9 16 15 / (390) depth in. (mm) Net weight lb. (kg) 97 (44) *Data according to pending standard testing procedures subject to review by the U.S. Dept. of Energy. A HE (High efficiency) system with low energy consumption has been
Summary of the content on the page No. 5
ILLUSTRATED MAIN FEATURES LIST Air outlet grid Timer cover (to adjust the timer slide cover sideways) Castor Castor stops Water collecting tray Air filter Air intake grid Exhaust hose Power cable comp. Manually resettable red button Water collecting tray drainage tube 5
Summary of the content on the page No. 6
ILLUSTRATED ACCESSORY LIST Table 1 DESCRIPTION SUPPLIED Exhaust hose 1 Stopper + flange 1 Caster stop 2 Window nozzle 1 Adjustable window bracket 1 Suction disc 2 ACCESSORY CHECK Check that all parts listed in Table 1 are included. 6
Summary of the content on the page No. 7
PERMANENT INSTALLATION The Pinguino accessories include two sets of flanges and stoppers, to be mounted in different locations (two different rooms). Once installed, these vents (flanges) are the only items needed for using Pinguino. fig. 1 Permanent installation outlet holes must be in an exterior wall and opening diameter should not 1 exceed 3” /2. INSIDE OUTSIDE INSIDE OUTSIDE A1 A2 fig. 2 fig. 3 in a window pane through the wooden base- section of a door or window INSIDE OUTSIDE 1”
Summary of the content on the page No. 8
30 cm TEMPORARY INSTALLATION Note: In both cases (permanent and temporary installations) make sure that the Pinguino is positioned on level ground. If necessary use the two caster stops for the front casters This installation makes it easy Suction discs may be used to Pinguino is equipped with an to use Pinguino in any room, keep window or door closed. adjustable window bracket. If provided there is a window or you have a sash window, a door: it allows you to use the place the bracket on the Pin
Summary of the content on the page No. 9
ELECTRICAL CONNECTION Check that the power supply voltage is 115 V ~ 60 Hz. Important: if you need to use and extension cord, please be sure to use a heavy duty extension cord (minimum 14 gauge). Before connecting the Pinguino to power supply, make sure that all switches on the front control panel are in the OFF position. Connect power cord found in storage compartment at rear of the fig. 9 Pinguino. FINAL CHECK In order to obtain the maximum performance from your air-conditioner make sure that:
Summary of the content on the page No. 10
4 4 9 9 10 DESCRIPTION OF PINGUINO PAC 210 U CONTROLS ON/OFF button ON/OFF pilot light A BC “Alarm” pilot light Timer ON/OFF pilot light Timer ON/OFF Selecting fan Timer notches Thermostat button speed button SETTING THE TIMER PROGRAMMED MODE The programmer/timer, like all clocks, must be 1) Release B timer button. set to the exact time. If for example it is 4.00 2) Set the operating times by pushing out the p.m., turn the dial in a clockwise direction notches on the dial corresponding to the (f
Summary of the content on the page No. 11
HOW TO START UP THE CONDITIONER (see control panel on the previous page) Plug the appliance into the mains. Select the “programmed” or “non programmed” mode (see previous page) Select the fan speed required pressing “Fan speed” key C. AIR-CONDITIONING Key A ON/OFF (conditioning) must be released Turn the thermostat to Max. Cold. Press key A (ON/OFF). ON/OFF signal lamp (conditioning) will come on. The appliance comes on. If not, refer to page 14. To switch off the appliance, press key A (ON/OFF
Summary of the content on the page No. 12
MAINTENANCE PRECAUTIONS fig. 14 fig. 15 During cleaning and normal maintenance operations Under no circumstances should appliance be remember to disconnect plug. washed with running water. Damage could be caused to the electrical circuit. CLEANING OF EXTERNAL HOUSING Use only mild soap and water. Do not use chemical cleaners. QQ ¢¢ QQ ¢¢ fig. 16 Clean with a damp cloth and dry thoroughly fig. 17 with a clean dry cloth. CONTROLS AT THE BEGINNING OF THE SEASON Carefully follow Check for any def
Summary of the content on the page No. 13
AIR FILTER CLEANING Maintenance of air filter Removal and replacement of air filter A clogged air filter reduces the quantity of Gently pull filter upwards. circulating air and the efficiency of the Push down to replace. appliance. Clean filter every week using a vacuum cleaner. fig. 19 fig. 20 Remove dust with a Rinse with running vacuum cleaner water fig. 21 Cleaning procedure To remove dust deposited on filter, use a vacuum cleaner. If it is very dirty, soak in lukewarm water and rinse thoro
Summary of the content on the page No. 14
TROUBLESHOOTING SYMPTOMS CAUSE SOLUTION The Pinguino does not - power failure - plug is disconnected - insert plug function: - ON/OFF switch is off - switch on - Timer key is in STOP position - release the TIMER key The Pinguino does not function - function fault warning - exhaust hose blocked - Check for obstruction of air light is on (page. 10 - outlet vent - exhaust hose twisted or bent - eliminate irregularities “Alarm” light) - ventilation holes on the rear of - remove obstacles to allow Af
Summary of the content on the page No. 15
FOR UNITED STATES ONLY: LIMITED WARRANTY We warrant each DeLonghi AIR-CONDITIONER to be free from defects in material and workmanship. Our obligation under this warranty is to provide one year parts and labor free from purchase date, with an additional four (4) years on any part of the sealed system consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing. This warranty shall apply only if the AIR-CONDITIONER is used in accordance with the factory directions w
Summary of the content on the page No. 16
16
Summary of the content on the page No. 17