Coleman Single Piece Air Handlers F*FP user manual

User manual for the device Coleman Single Piece Air Handlers F*FP

Device: Coleman Single Piece Air Handlers F*FP
Category: Air Conditioner
Manufacturer: Coleman
Size: 0.23 MB
Added : 3/1/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Coleman Single Piece Air Handlers F*FP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Coleman Single Piece Air Handlers F*FP.

For your convenience

If looking through the Coleman Single Piece Air Handlers F*FP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Coleman Single Piece Air Handlers F*FP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Coleman Single Piece Air Handlers F*FP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Coleman Single Piece Air Handlers F*FP User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Coleman Single Piece Air Handlers F*FP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Coleman Single Piece Air Handlers F*FP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION MANUAL
SINGLE PIECE
AIR HANDLERS
ISO 9001
MODELS: F*FP
Certified Quality
Management System
TABLE OF CONTENTS
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 COIL METERING DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SPECIFIC SAFETY RULES AND PRECAUTIONS . . . . . . . . . . . . . . . 2 REFRIGERANT LINE CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . .6
SAFETY REQUIREMENTS . . . . . . .

Summary of the content on the page No. 2

292043-UIM-B-0707 Top and side power wiring and control wiring, accessible screw termi- SPECIFIC SAFETY RULES AND PRECAUTIONS nals for control wiring, easy to install drain connections and electric heaters all combine to make the installation easy, and minimize installa- tion cost. FIRE OR ELECTRICAL HAZARD INSPECTION Failure to follow the safety warnings exactly could result in serious As soon as a unit is received, it should be inspected for possible dam- injury, death or property damage. age

Summary of the content on the page No. 3

292043-UIM-B-0707 6. When an evaporator coil is installed in an attic or above a finished ceiling, an auxiliary drain pan should be provided under the coil as is specified by most local building codes. 7. Proper electrical supply must be available. If electric heat is used, a minimum clearance of 1” must be main- tained on all sides of the supply air duct and/or plenum continuously 8. Clearances must also be taken into consideration, and provided for up to 3’ (See Figure 1). for as follows: A.

Summary of the content on the page No. 4

292043-UIM-B-0707 BLOWER 4A- FRONT VIEW COMPARTMENT (ACCESS PANEL PRIMARY SUPPORT REMOVED) DRAIN BLOWER BRACKET 3/4" PVC SOCKETS PRIMARY HOUSING FOR HORIZONTAL DRAIN DRAIN APPLICATION 060 COIL BAFFLE SECONDARY (SHOWN IN DRAIN SECONDARY RIGHT-HORIZONTAL DRAIN POSITION) HORIZONTAL CENTER ACCESS PANEL DRAIN PAN 4C - FRONT VIEW POSITION "B” COIL COMPARTMENT (ACCESS PANEL REMOVED) VERTICAL 4B - SIDE VIEW DRAIN PAN HORIZONTAL DRAIN PAN SECONDARY FILTER POSITION "A” DRAIN UPFLOW 3/4" THREADED FILTER PR

Summary of the content on the page No. 5

292043-UIM-B-0707 A suspension kit is available. Models 1BH0601 (unit sizes 018-060) is DUCT CONNECTIONS designed specifically for the units contained in this instruction (upflow application only). For installation of these accessory kits, see the instructions packed with the kit. For suspension of these units in horizontal applications, it is recom- Use 1/2" screws to connect ductwork to bottom of unit. Longer screws will pierce the drain pan and cause leakage. If pilot holes mended to use angl

Summary of the content on the page No. 6

AIR FLOW 292043-UIM-B-0707 • If the suction line is 3/4" diameter - position the bulb near the top only, install the 6-pin jumper plug to the control board to bypass the of the copper tube as shown. If the tube is 7/8" diameter - position heater limit controls. This jumper plug is secured to the duct cover near the bulb near the bottom of the tube. Refer to Figure 7. the 4-pin power plug harness. Failure to install the plug will cause the blower to run continuously. (See Figure 8). • Wrap the c

Summary of the content on the page No. 7

292043-UIM-B-0707 Unitary Products Group 7

Summary of the content on the page No. 8

292043-UIM-B-0707 NOTE: It is possible to vary the amount of electric heat turned on during LOW VOLTAGE CONTROL CONNECTION the defrost cycle of a heat pump. Standard wiring will only bring on 5 The 24 volt power supply is provided by an internally wired low voltage KW of electric heat during defrost see Table 6 and Figures 12 and 13 for transformer which is standard on all models. However, if the unit is con- alternate staging. nected to a 208 volt power supply the low voltage transformer must b

Summary of the content on the page No. 9

292043-UIM-B-0707 TABLE 3: Physical and Electrical Data Models F*FP 024 030 036 040 Blower - Diameter x Width 10 x 6 10 x 8 10 x 8 10 x 8 HP 1/4 1/3 1/2 1/3 Motor Nominal RPM 1075 1075 1075 1075 Voltage 208/230 Full Load (208/230) 1.6/1.4 (50 Hz:2.1) 2.5 / 2.2 3.3/2.9 (50 Hz:2.3) 2.5 / 2.2 Amps Locked Rotor (208/230) 3.3 / 2.9 6.2 / 5.5 7.4 / 6.5 6.2 / 5.5 Type DISPOSABLE OR PERMANENT 1 Size 16 x 20 x 1 16 x 20 x 1 20 x 20 x 1 20 x 20 x 1 Filter Permanent Type Kit 1PF0601BK 1PF0601BK 1PF0602BK 1

Summary of the content on the page No. 10

292043-UIM-B-0707 1 TABLE 6: Electrical Data - 1 Ø - 208/230-1-60 2 3 Max. Static Total Heat KW Staging Heater* & Min. CFM Models F*FP KW MBH W1 Only W2 Only W1 + W2 Model Static Tap 208V 240V 208V 240V 208V 240V 208V 240V 208V 240V 2HK*6500506B Low 3.8 5.0 13.0 17.1 3.8 5.0 3.8 5.0 3.8 5.0 024 2HK*6500806B 0.5 Low 5.6 7.5 19.1 25.6 3.8 5.0 5.6 7.5 5.6 7.5 2HK*6501006B Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 10.0 7.5 10.0 2HK*6500506B Low 3.8 5.0 13.0 17.1 3.8 5.0 3.8 5.0 3.8 5.0 2HK*6500806B Low 5.6

Summary of the content on the page No. 11

292043-UIM-B-0707 1 TABLE 7: Electrical Data - (For Single Source Power Supply) - Copper Wire 1 Ø - 208/230-1-60 Field Wiring Heater Heater* 2 Models F*FP Amps Min. Circuit Ampacity 75°C Wire Size - AWG Max. O.C.P. Amps/Type Model 240V 208V 240V 208V 240V 208V 240V 2HK*6500506B 20.8 24.7 27.7 25 30 10 10 024 2HK*6500806B 31.3 35.5 40.7 40 45 8 8 2HK*6501006B 41.7 46.9 53.7 50 60 8 6 2HK*6500506B 20.8 25.8 28.7 30 30 10 10 2HK*6500806B 31.3 36.7 41.7 40 45 8 8 030 2HK*6501006B 41.7 48.1 54.7 50

Summary of the content on the page No. 12

292043-UIM-B-0707 1 TABLE 9: Electrical Data - 3 Ø - 208/230-3-60 3 Max. Static Total Heat KW Staging 2 Heater & Min. CFM Models F*FP KW MBH W1 Only W2 Only W1 + W2 Model Static Tap 208 240 208 240 208 240 208 240 208 240 024 2HK06501025B 0.5 Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 5.0 7.5 10.0 2HK06501025B 0.5 Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 5.0 7.5 10.0 030 2HK06501525B 0.5 High 11.3 15.0 38.6 51.2 3.8 5.0 7.5 10.0 11.3 15.0 2HK06501025B 0.5 Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 5.0 7.5 10.0 036 2H

Summary of the content on the page No. 13

292043-UIM-B-0707 1 TABLE 11: Airflow Data for 230 Volt - Heat Pump Models 230 Volt Blower Motor Models CFM @ External Static Pressure - IWC Speed 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 High 950 910 865 835 775 730 662 590 502 400 F4FP024H06T2* Med 845 815 785 745 705 654 594 524 439 344 Low 650 630 605 575 540 508 450 383 285 158 High 1,270 1,210 1,150 1,085 1,015 946 862 769 645 502 F4FP030H06T2* Med 1,050 1,040 995 930 855 804 714 624 494 364 Low 855 820 780 735 680 624 550 447

Summary of the content on the page No. 14

292043-UIM-B-0707 1 TABLE 12: Airflow Data for 208 Volt - Heat Pump Models 208 Volt Blower Motor Models CFM @ External Static Pressure - IWC Speed 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 High 855 819 779 752 698 657 596 531 452 360 F4FP024H06T2* Med. 760 733 706 670 634 589 535 472 395 310 Low 585 567 545 518 486 457 405 344 257 142 High 1143 1089 1035 977 914 851 776 692 581 451 F4FP030H06T2* Med. 941 936 895 837 770 724 643 562 445 328 Low 770 738 702 662 612 561 495 402 300 171 Hig

Summary of the content on the page No. 15

292043-UIM-B-0707 F* SERIES F* SERIES Air Handler Control Wiring Air Handler Control Wiring Typical A/C - Cooling only Applications Typical A/C with Electric Heat Applications AIR HANDLER AIR HANDLER THERMOSTAT THERMOSTAT 1-STAGE 1-STAGE BOARD BOARD AIR CONDITIONING AIR CONDITIONING RR RR Y Y Y Y Y Y G G G G Field W1 W1 1 W1 W1 1 HUMIDISTAT HUMIDISTAT Installed W2 W2 W2 W2 Jumper - If Required O O C C C C C C HUM HUM CFM selection CFM selection 1 1 X X NOTE: NOTE: board only on board only on Deh

Summary of the content on the page No. 16

The drain pan connections are designed to ASTM Standard D 2466 DRAIN CONNECTIONS Schedule 40. 3/4" PVC is preferred. Since the drains are not subject to All drain lines should be trapped a minimum of three inches, should be any pressure it is not necessary to use Schedule 40 pipe for drain lines. pitched away from unit drain pan and should be no smaller than the coil It is recommended that all drain connections be sealed with teflon tape drain connection. or equivalent. MAINTENANCE Filters must


Alternative user manuals
# User manual Category Download
1 Coleman 100-RANG User manual Air Conditioner 15
2 Coleman SPC-100RANG User manual Air Conditioner 2
3 Sony SU-PW2 User manual Air Conditioner 12
4 Sony CV-P12PX User manual Air Conditioner 3
5 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
6 Sony VGN-BX500 User manual Air Conditioner 1
7 Philips 190S5 User manual Air Conditioner 21
8 Philips Comfort-Cire AMC 45 User manual Air Conditioner 7
9 Philips Comfort-Cire AMC 30 User manual Air Conditioner 2
10 Philips CS-E15DB4EW User manual Air Conditioner 4
11 Philips GOGEAR SA3425 User manual Air Conditioner 1
12 Philips 3160 User manual Air Conditioner 7
13 Philips Comfort-Cire AMW User manual Air Conditioner 3
14 Philips Comfort-Cire AMC 25 User manual Air Conditioner 2
15 Philips GoGear SA3446 User manual Air Conditioner 0