Carrier High Wall Duct Free Split System 40MVC user manual

User manual for the device Carrier High Wall Duct Free Split System 40MVC

Device: Carrier High Wall Duct Free Split System 40MVC
Category: Air Conditioner
Manufacturer: Carrier
Size: 0.59 MB
Added : 8/28/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier High Wall Duct Free Split System 40MVC. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier High Wall Duct Free Split System 40MVC.

For your convenience

If looking through the Carrier High Wall Duct Free Split System 40MVC user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier High Wall Duct Free Split System 40MVC on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier High Wall Duct Free Split System 40MVC to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier High Wall Duct Free Split System 40MVC User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier High Wall Duct Free Split System 40MVC but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier High Wall Duct Free Split System 40MVC. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

38MVC/40MVC
38MVQ/40MVQ
Comfortt Series High---Wall Duct---Free Split System
Sizes009 --- 024
ServiceManual
TABLEOFCONTENTS
SAFETY CONSIDERATIONS
PAGE
Improper installation, adjustment, alteration, service, maintenance,
SAFETY CONSIDERATIONS ......................... 1 or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property
STANDARD FEATURES AND ACCESSORIES........... 2
damage. Consult a qualified installer, service agency, or y

Summary of the content on the page No. 2

MODELNUMBERNOMENCLATURE INDOOR UNIT 40 MVC 018 3---01 --- Voltage --- --- 30VDC 1 --- 115---1---60 Fan Coil Unit 3 --- 208/230---1---60 NominalCapacity 009 --- 3/4 Ton 012 --- 1 Ton UnitType 018 --- 1---1/2 Ton MVC --- Cooling Only 024 --- 2 Tons MVQ --- Heat Pump OUTDOORUNIT 38 MVC 018 3---01 --- Voltage 1--- 115---1---60 Air---Cooled Condenser 3--- 208/230---1---60 NominalCapacity 009 --- 3/4 Ton UnitType 012 --- 1 Ton MVC --- Cooling Only 018 --- 1---1/2 Ton MVQ --- Heat Pump 024 --- 2 Tons S

Summary of the content on the page No. 3

STANDARDFEATURESANDACCESSORIES EaseOfInstallation INDOORUNITS Mounting Brackets S LowVoltageControls S ComfortFeatures MicroprocessorControls S WirelessRemoteControl S AutomaticAir Sweep S AirDirection Control S AutoRestartFunction S Cold BlowProtection On HeatPumps S Turbo Mode On Sizes 9K and 12 K S AutoChangeoverOn HeatPumps S EnergySavingFeatures Sleep Mode S A07892 Stop/StartTimer S SafetyAndReliability Fig.1–CondensatePump 3MinuteTimeDelayForCompressor S On high wallfan coils,thecondensate

Summary of the content on the page No. 4

SPECIFICATIONS-- COOLINGONLYUNITS SystemModelNumber 53MVC009---------1 53MVC012---------1 53MVC012---------3 53MVC018---------3 SystemVoltage 115V 115V 208/230 208/230 ControlVoltage 0 --- 12 Pulse DC 0 --- 12 Pulse DC 0 --- 12 Pulse DC PulseDC Capacity (Btuh) 9000 12000 12000 18000 SEER 13.0 13.0 13.0 13.0 RefrigerantType R---410A Design Pressure(PSIG) 550 550 550 550 Metering Device CapillaryTubeinOutdoorUnit Charge(lb) 2.3 2.9 3.0 4.4 Type Rotary Model EA82X1C---1FZDU1 EA108X1C---1FZDU1 PA108

Summary of the content on the page No. 5

SPECIFICATIONS-- HEATPUMPUNITS SystemModelNumber 53MVQ009---------1 53MVQ012---------1 53MVQ012---------3 53MVQ018---------3 SystemVoltage 115V 115V 208/230 208/230 ControlVoltage 0 --- 12 Pulse DC 0 --- 12 Pulse DC 0 --- 12 Pulse DC PulseDC Capacity (Btuh) 9000 12000 12000 18000 SEER 13.0 13.0 13.0 13.0 HSPF 7.7 7.7 7.7 7.7 RefrigerantType R---410A Design Pressure(PSIG) 550 550 550 550 Metering Device CapillaryTubesinOutdoorUnit Charge(lb) 2.35 3.0 3.0 Type Rotary Model EA82X1C---1FZDU1 EA108X1

Summary of the content on the page No. 6

DIMENSIONS -- INDOOR A07336 W H D ModelSize Weight lb(kg) in.(mm) in.(mm) in.(mm) 9K 32.09(815) 11.02(280) 7.68(195) 24.2 (11) 12K 35.67(906) 11.26(286) 9.25(235) 33.0 (15) 18K 49.21(1250) 12.80(325) 9.06(230) 55.0 (25) 55.0 (25) 24K 49.21(1250) 12.80(325) 9.06(230) DIMENSIONS -- OUTDOOR Air Flow W L1 35 A07337 W H L1 L2 L3 Weight lb(kg) Weight lb(kg) ModelSize CoolingOnly HeatPumps in.(mm) in.(mm) in.(mm) in.(mm) in.(mm) 77.0(35) 79.2(36) 9K 30.71(780) 21.26(540) 21.61(549) 11.81(300) 10.87(276

Summary of the content on the page No. 7

CLEARANCES -- INDOOR 6" (0.15m) min. 5" 5" (0.13m) (0.13m) min. min. (1.8m) 6' A07891 Fig.2–Indoorunitclearance CLEARANCES -- OUTDOOR A Air-inlet E D B C Air-outlet A07894 UNIT 9k and 12k in. (mm) 18kand24kin.(mm) A 24(610) 24(610) B 24(610) 36(914) C 24(610) 24(610) D 4(102) 12(305) E 12(305) 12(305) Fig.3–OutdoorUnitClearance 7 38/40MVC,MVQ

Summary of the content on the page No. 8

SYSTEMOPERATINGENVELOPE 53MVC/MVQ System Operating Envelope Chart Outdoor Temperature (ºC) -40 -35 -30 -25 -20 -15 -10 -5 0 5 1015202530354045505560 120 60 55 110 50 100 45 40 90 35 85º F 80 80ºF 30 Cooling Continuous 25 Heating 70 Operation Continuous 20 Operation 62ºF 60 15 55ºF 125º 10 55º 75ºF 50 5ºF 5 40 0 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Outdoor Temperature (ºF) Uselowambientcontroliftheunitwilloperateincoolingatambientconditionsbelow55_F(12.78

Summary of the content on the page No. 9

WIRING The main power is supplied to the outdoor unit. The field supplied connecting cable from the outdoor unit to indoor unit consists of four wiresand providesthepowerfortheindoorunitaswellasthecommunication signalbetween theoutdoorunitand indoorunit. Voltagedrop on theconnecting cableshould bekeptto aminimum. Usecablesizeand max length below: 18AWG 50ft.(16m) 16AWG 100ft.(33m) CONNECTIONDIAGRAMS CONNECTING CABLE CONTROL CONTROL CONNECTING CABLE CONNECTING CABLE Notes: 1.Donotusethermostatwir

Summary of the content on the page No. 10

10 38/40MVC,MVQ WIRINGDIAGRAMS Fig.6–WiringDiagram38MVC009------1W/40MVC009------1

Summary of the content on the page No. 11

11 WIRINGDIAGRAMS(CONT.) Fig.7–WiringDiagram38MVC012------1W/40MVC012------1 38/40MVC,MVQ

Summary of the content on the page No. 12

12 38/40MVC,MVQ WIRINGDIAGRAMS(CONT.) Fig.8–WiringDiagram38MVC012------3W/40MVC012------3

Summary of the content on the page No. 13

13 WIRINGDIAGRAMS(CONT.) Fig.9–WiringDiagram38MVC018------3W/40MVC018------3 38/40MVC,MVQ

Summary of the content on the page No. 14

14 38/40MVC,MVQ WIRINGDIAGRAMS(CONT.) Fig.10–WiringDiagram38MVQ009------1W/40MVQ009------1

Summary of the content on the page No. 15

15 WIRINGDIAGRAMS(CONT.) Fig.11–WiringDiagram38MVQ012------1W/40MVQ012------1 38/40MVC,MVQ

Summary of the content on the page No. 16

16 38/40MVC,MVQ WIRINGDIAGRAMS(CONT.) Fig.12–WiringDiagram38MVQ012------3W/40MVQ012------3

Summary of the content on the page No. 17

REFRIGERATIONCYCLEDIAGRAM FIELD PIPING FLARE CONNECTION TWO PHASE LIQUID LINE CAPILLARY TUBE SERVICE VALVE HEAT HEAT EXCHANGER EXCHANGER (CONDENSER) (EVAPORATOR) SERVICE VALVE W/GUAGE PORT SUCTION LINE FLARE CONNECTION COMPRESSOR FIELD PIPING A08104 Fig.13–Cooling INDOOR UNIT OUTDOOR UNIT FLARE CONNECTION CHECK VALVE TWO PHASE (HEATING MODEL ONLY) LIQUID LIQUID HTG CAPILLARY TUBE SERVICE VALVE HEAT HEAT EXCHANGER EXCHANGER (CONDENSER) (EVAPORATOR) SERVICE VALVE SUCTION W/ GUAGE PORT DISCHARGE

Summary of the content on the page No. 18

LongLineApplications,38MVCUnits: REFRIGERANTLINES 1. A crankcase heater should be added for line lengths longer Generalrefrigerantlinesizing: than 25 ft (7.62 m) to preventthe migration of refrigerantto 1. The 38MVC/MVQ units are shipped with a full charge of thecompressorduring the“OFF”cycle. R410A refrigerant. All charges, line sizing, and capacities 2. A field fabricated wind baffleisrecommended. are based on runs of 25 ft (7.6 m). For runs over 25 ft (7.6 3. No changein linesizing isrequired

Summary of the content on the page No. 19

DeepVacuumMethod SYSTEMEVACUATIONAND The deep vacuum method requires a vacuum pump capable of CHARGING pulling a vacuum of 500 microns and a vacuum gage capable of accurately measuring thisvacuumdepth.Thedeep vacuummethod is the most positive way of assuring a system is free of air and ! CAUTION liquid water.(SeeFig.17) 5000 UNITDAMAGEHAZARD 4500 Failure to follow this caution may result in equipment 4000 damageorimproperoperation. LEAKIN 3500 SYSTEM Neverusethesystem compressorasavacuum pump. 3

Summary of the content on the page No. 20

CONTROLSYSTEM The40MVC/MVQ unitisequipped with amicroprocessorcontrolto perform two functions: 1. Providesafety forthesystem 2. Controlthesystem and provideoptimum levelsofcomfortand efficiency The main microprocessor is located on the control board of the fan coil unit (outdoor units have a microprocessor too) with thermistors located in thefan coilairinletand on theindoorcoil. Heatpump unitshaveathermistoron theoutdoorcoil. Thesethermistors monitorthe system operation to maintain the unit with


Alternative user manuals
# User manual Category Download
1 Carrier 024 User manual Air Conditioner 588
2 Carrier 09DK054-094 User manual Air Conditioner 100
3 Carrier 09DK054-084 User manual Air Conditioner 48
4 Carrier 17DA User manual Air Conditioner 26
5 Carrier 09DC User manual Air Conditioner 32
6 Carrier 040-420 User manual Air Conditioner 66
7 Carrier 17EX User manual Air Conditioner 14
8 Carrier 19 User manual Air Conditioner 17
9 Carrier 1995 User manual Air Conditioner 31
10 Carrier 09BB User manual Air Conditioner 11
11 Carrier 19DG User manual Air Conditioner 17
12 Carrier 19XRV User manual Air Conditioner 90
13 Carrier 30GA User manual Air Conditioner 32
14 Carrier 30GB User manual Air Conditioner 178
15 Carrier 30GX080-176 User manual Air Conditioner 22
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21