Carrier 90MA/MF/MU user manual

User manual for the device Carrier 90MA/MF/MU

Device: Carrier 90MA/MF/MU
Category: Air Conditioner
Manufacturer: Carrier
Size: 0.56 MB
Added : 8/28/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier 90MA/MF/MU. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier 90MA/MF/MU.

For your convenience

If looking through the Carrier 90MA/MF/MU user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier 90MA/MF/MU on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier 90MA/MF/MU to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier 90MA/MF/MU User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier 90MA/MF/MU but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier 90MA/MF/MU. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Marine/Industrial
SinglePackage
CoolingUnit
Models
90MA/MF/MU,DesignSeriesTwo
BeginningSerialNumberC00400
62--10458--00
INSTALLATION
OPERATION&SERVICE

Summary of the content on the page No. 2

OPERATIONANDSERVICEMANUAL MARINE/INDUSTRIALSINGLEPACKAGE COOLINGUNIT MODELS 90MA/MF/MU,DesignSeriesTwo BeginningSerialNumberC00400 Carrier Refrigeration Operations, A member of theUnitedTechnologies Corporationfamily. Stock symbolUTX. Carrier Transicold,Carrier Corporation,P.O.Box 4805,Syracuse,N.Y.13221 U.S.A. Carrier Corporation2000 D PrintedinU.S.A.0700

Summary of the content on the page No. 3

SAFETYSUMMARY GENERALSAFETYNOTICES The following general safety notices supplement the specific warnings and cautions appearing elsewhere in this manual.Theyarerecommendedprecautionsthatmustbeunderstoodandappliedduringoperationandmaintenance oftheequipmentcoveredherein.Thegeneralsafetynoticesarepresentedinthefollowingthreesectionslabeled:First Aid,OperatingPrecautionsandMaintenancePrecautions.Alistingofthespecificwarningsandcautionsappearing elsewherein themanual follows thegeneral safety notice

Summary of the content on the page No. 4

CAUTION Sharpedgesofcoilfinsareexposed.Topreventinjury,covertopofevaporatorwithcardboardorafew layersofheavytape. CAUTION Toavoidcoildamage,coverevaporatorfacewithplywoodorotherrigidsheetmaterial.Ifanycoilfins aremashedorbent,straightenwithacoilfincombofthepropertoothspacing(referto“coilfins/inch” in Table1 through Table2). Check forrefrigerantleaks. CAUTION Beforeattemptingtoremovefan motorsormotormounts,placeapieceofplywood overevaporator coilstopreventcoil damage. 62--10458--00 Safety-2

Summary of the content on the page No. 5

TABLEOFCONTENTS PARAGRAPHNUMBER Page GENERALSAFETYNOTICES ..................................................... Safety-1 FIRSTAID ...................................................................... Safety-1 OPERATINGPRECAUTIONS ...................................................... Safety-1 MAINTENANCEPRECAUTIONS .................................................. Safety-1 SPECIFIC WARNINGANDCAUTIONSTATEMENTS ................................. Safety-1 1. INTRODUCTION ..........................

Summary of the content on the page No. 6

LISTOFILLUSTRATIONS FIGURENUMBER Page Figure1BaseUnit InteriorDetails(Typical) ................................................ 1 Figure2Unit Dimensions ............................................................... 5 Figure3 Horizontal Wheel Centering ...................................................... 5 Figure4 ConcentricWheel Alignment ..................................................... 5 Figure5ConnectionLocations ........................................................... 6 Figure6Typ

Summary of the content on the page No. 7

1. INTRODUCTION 3.1 Inspect Unit Checkunitagainstshippingorder.Inspectcarefullyfor The 90M series single--package cooling units (See concealedshippingdamage.Ifshipmentisdamagedor Figure1) are designed to provide air conditioning aboard marine vessels and in industrial applications. incomplete,fileclaimwithtransportationcompanyand The 90MA units are fitted with sea water cooled advise Carrier Transicold immediately. condensers while the 90MF units are fitted with fresh 3.2 Protect Unit fromDamage

Summary of the content on the page No. 8

Table190MA/MF/MUPhysical Data -- Refrigerant 22 R--22 -- English Units R--22 -- MetricUnits BASEUNIT90MA/MF/MU UNITS 204 206 208 212 204 206 208 212 English (Metric) NOMINALCAPACITY Tons (kW) 3 5 7.5 10 10.5 17.6 26.4 35.1 OPERATING WEIGHT BaseUnit -- 90MA/MF Pounds (kg) 390 427 895 950 177 194 406 431 BaseUnit -- 90MU Pounds (kg) 330 360 835 890 150 163 379 404 DischargePlenum Pounds (kg) 25 25 50 50 11.3 11.3 22.7 22.7 COMPRESSOR TYPE WeldedHermetic Semi--Hermetic WeldedHermetic Semi--Hermetic

Summary of the content on the page No. 9

Table290MA/MF/MUPhysical Data -- Refrigerant 407C R--407C -- English Units R--407C -- MetricUnits BASEUNIT90MA/MF/MU UNITS 404 406 408 412 404 406 408 412 English (Metric) NOMINALCAPACITY Tons (kW) 3 5 7.5 10 10.5 17.6 26.4 35.1 OPERATING WEIGHT BaseUnit -- 90MA/MF Pounds (kg) 390 427 895 950 177 194 406 431 BaseUnit -- 90MU Pounds (kg) 330 360 835 890 150 163 379 404 DischargePlenum Pounds (kg) 25 25 50 50 11.3 11.3 22.7 22.7 COMPRESSOR TYPE WeldedHermetic Semi--Hermetic WeldedHermetic Semi--He

Summary of the content on the page No. 10

Table390MA/MF Physical Data -- Refrigerant 134a R--134a -- English Units R--134a -- MetricUnits BASEUNIT90MA/MF UNITS 308 312 308 312 English (Metric) NOMINALCAPACITY Tons (kW) 5.5 8 19.3 28.1 OPERATING WEIGHT BaseUnit Pounds (kg) 895 950 406 431 DischargePlenum Pounds (kg) 50 50 22.7 22.7 COMPRESSOR TYPE -- Reciprocating Semi--Hermetic Semi--Hermetic Quantity ofCylinders 4 6 4 6 Quantity ofUnloadingCylinders 0 2 0 2 Quantity ofCapacity Steps 1 2 1 2 DISCHARGEPRESSURESWITCH Opens psig(kPa) 3351

Summary of the content on the page No. 11

UNIT 004 006 008,012 A 36.19(919) 48(1219) B 21.88(556) 29.62(752) C 59.12(1501) 69.50(1765) D SEENOTE2 E 24(610) F 13.81(351) 16.44(418) 19.38(492) G 13.13(333) 15(381) 17.25(438) H 0.75(19) 0.75(19) 1.31(33) J 12.5(318) 10.62(270) 11.44(291) K 17.06(433) 23.25(591) L 20.50(521) 25.37(644) M 17(432) 17(432) N 31.88(810) 42.62(1083) P 2.06(52) 3(76) Q 10(254) 12.50(318) R 15.56(395) 16(406) NOTES: 1. Certified dimension drawings available upon request 2. Minimum required clearance at back of uni

Summary of the content on the page No. 12

90MA/MU008/012UNITS 90MA/MF004/006UNITS 90MU008/012UNITS 90MU004/006UNITS UNIT A* B* C* D* E F G 90MA/MF004 1/2 1/2 ---- ¾FPT ---- ---- 1.75 90MA/MF006 3/4 ---- 3/4 ---- ---- (45) 90MA/MF008/012 1” 1” ---- ---- ---- 90MU004 ---- ---- ---- 1/2flare 1/2flare 90MU006 ---- ---- ---- 1/2flare 1/2flare 90MU008/012 ---- ---- ---- 5/8O.D. 3/4O.D. *A=CondenserIn,B&C =CondenserOut, D=Condensate,allFemalePipeThread,E=LiquidRefrigerant(fieldcut),F= Refrigerant Discharge (field cut), G= Electrical Opening Fi

Summary of the content on the page No. 13

Table4Recommended LineSizes, RemoteCondenser UNIT LENGTHOF RUN ((90MU)) 0--25 26--50 51--75 76--100 DISCH LIQUID DISCH LIQUID DISCH LIQUID DISCH LIQUID 004 1/2 (1.3) 1/2(1.3) 5/8(1.6) 1/2(1.3) 5/8(1.6) 1/2(1.3) 7/8(2.2) 1/2(1.3) 006 5/8(1.6) 1/2(1.3) 7/8(2.2) 1/2(1.3) 7/8(2.2) 1/2(1.3) 7/8(2.2) 1/2(1.3) 008 7/8(2.2) 5/8(1.6) 7/8(2.2) 5/8(1.6) 7/8(2.2) 5/8(1.6) 1-1/8(2.9) 5/8(1.6) 012 7/8(2.2) 5/8(1.6) 1-1/8(2.9) 5/8(1.6) 1-1/8(2.9) 5/8(1.6) 1-1/8(2.9) 5/8(1.6) NOTES: 1. Linesizes given in inches

Summary of the content on the page No. 14

e. Allow crankcase heater to remain energized (unit power on) for at least 24 hours. Open any valves in condensercoolingwatersupplylinesandthensetse- lectorswitchatCOOLposition.Ifroomtemperature isabovethermostatsettingcompressorwillstart.On first start--up, set water regulating valve. (Refer to paragraph5.7.) f. Set thermostat forcomfort as desired. 4.2 To Shut Down Unit a. TurnselectorswitchtoOFFposition.Donotshutoff main power except to service unit. The crankcase heaterisoperativeonlywhenmai

Summary of the content on the page No. 15

5.2 AccessPanel Removal switch T--HIGHtoenergizeliquidlinesolenoid(LLS) [to activatethe full evaporator coil and all compressor a. Removereturn--airgrilleas described above. cylinders]. Ifthermostatswitch T--HIGHis notcalling b.Removethepanel fastening screws nowexposed. for cooling, power flows to energize compressor unloader solenoid (US) [to unload compressor c. Pull out and down to removetop panel. cylinders]. d.Pull out and up to removebottom panel. When room temperature falls to the cutout

Summary of the content on the page No. 16

BELT TENSION ADJUSTMENT -- Shut off unit power springtension,decreasewaterflowandincreasepres- supply. Loosen fan motor from mounting bracket. Do sure. notloosenmotormountingbracketfromunit.Movefan If pressure reading is above operating range, rotate motorup ordown untilproperbelttension isachieved thesquarehead adjusting screwclockwise; this will (approximately 3/4--in. deflection with 8--pound decreasespring tension,increasewaterflow andde- tension at midpoint ofbelt span). creasepressure. Lub

Summary of the content on the page No. 17

c. Regulateflowtocondenserwithasupplylinevalve. (1607kPa)forR--407Cunits.Chargetoaclearsight Ifpumpisanon--overloadingtype,thevalvemaybe glass. fullyclosedwhilepumpisrunning.Foraveragescale deposit,allowsolutionto remainin condenserover- 90MU004 UNITS R--22 night. Forheavy scaledeposit, allow24 hours. d.Drain condenserand flush with clean water. 90MU006 UNITS R--22 Figure10Forced Circulation Method 5.9 RefrigerantCharging 90MA/MF -- These units are shipped with a full operating charge. If rechar

Summary of the content on the page No. 18

TM 5.10 EvaporatorFan MotorRemoval 5.13 Cycle--Loc -- Protection Device All units are equipped with Cycle--LOC a. Shut offunit main powersupply. current--sensinglockoutrelay.Thisdevicewilllockout thecompressorafteranysafetytrip(dischargepressure switch,suction--pressureswitch,orinternaloverloadof WARNING the compressor). Check reason for lockout before Lock open and tag unit disconnect before resettingthedevice.Refertounitlabelwiringdiagram. working on fan motor. Remove fuses and To reset, turn

Summary of the content on the page No. 19

Figure12Mounting Base 62--10458--00 13 A USEDON A B C D E F G H J K L M N P R S T V W 004/006 SIZE 10.00 40.25 22.00 38.25 36.25 -- -- 18.005 -- -- 3.18 2.56 8.75 2.00 1.00 5.00 7.50 15.00 0.70 008/012 SIZE 15.38 52.00 27.31 50.00 48.00 1.25 45.50 23.31 0.75 25.81 -- -- -- -- -- 9.00 6.00 16.50 -- BASED ON DRAWING 50BW400093

Summary of the content on the page No. 20

WIREPASSESTHOUGH LOOPOFCL CC IPC 11 21 L1 BLK 1 FIELD 12 22 BLU L2 2 POWER C L3 13 23 YEL 3 SUPPLY G IFC IPF GROUND YEL 11 21 YEL T3 12 22 T2 BLU BLU IFM 13 23 BLK BLK T1 GRN ORN BLK BLU CHR BLK BLU 4 5 BLK VIO H3 H5 CH H1 H2 H4 H6 SEENOTE1 TRAN GRN RED F RED X1 X2 BRN C2 CC 24VOLT (SEENOTE3) SW BRN C2 CHR IFC BRN NO VIO TB1--1 RED CC ORN NC BRN TRAN CHR NO YEL TB1--4 RED 1 3 RED CC BRN C2 IFC 90MU UNITS ONLY RED YEL RED CFR BRN ORN CL LOGIC BRN TB1--3 T--LOW X 1 W 3 TB1--5 RED 2 BRN R CHR B BRN


Alternative user manuals
# User manual Category Download
1 Carrier 024 User manual Air Conditioner 588
2 Carrier 09DK054-094 User manual Air Conditioner 100
3 Carrier 09DK054-084 User manual Air Conditioner 48
4 Carrier 17DA User manual Air Conditioner 26
5 Carrier 09DC User manual Air Conditioner 32
6 Carrier 040-420 User manual Air Conditioner 66
7 Carrier 17EX User manual Air Conditioner 14
8 Carrier 19 User manual Air Conditioner 17
9 Carrier 1995 User manual Air Conditioner 31
10 Carrier 09BB User manual Air Conditioner 11
11 Carrier 19DG User manual Air Conditioner 17
12 Carrier 19XRV User manual Air Conditioner 90
13 Carrier 30GA User manual Air Conditioner 32
14 Carrier 30GB User manual Air Conditioner 178
15 Carrier 30GX080-176 User manual Air Conditioner 22
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21