Carrier 50VL---A user manual

User manual for the device Carrier 50VL---A

Device: Carrier 50VL---A
Category: Air Conditioner
Manufacturer: Carrier
Size: 2.79 MB
Added : 8/28/2013
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier 50VL---A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier 50VL---A.

For your convenience

If looking through the Carrier 50VL---A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier 50VL---A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier 50VL---A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier 50VL---A User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier 50VL---A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier 50VL---A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

50VL---A
Performancet14SEER Single---Packaged AirConditioner
System withPuron ® (R---410A) Refrigerant
Single and Three Phase
2---5 Nominal Tons (Sizes 24---60)
Installation Instructions
NOTE: Read the entire instruction manual before starting the
installation.
NOTE: Installer: Make sure the Owner’s Manual and Service
Instructions are left with the unit after installation.
TABLEOFCONTENTS
PAGE
SAFETY CONSIDERATIONS ....................... 1--2
INTRODUCTION ................................... 2
R

Summary of the content on the page No. 2

Step2—ProvideUnitSupport ! IMPORTANT: The unit must be secured to the curb by installing WARNING screwsthrough thebottom ofthecurb flangeand intotheunitbase ELECTRICALSHOCKHAZARD rails. When installing large base units onto the common curb, the Failure to follow this warning could result in personal screwsmustbeinstalled beforeallowing thefull weightof theunit injuryordeath. to reston thecurb. A minimum ofsix screws arerequired forlarge base units. Failure to secure unit properly could result in

Summary of the content on the page No. 3

A09462 Fig.2 -- 50VL--A24--36UnitDimensions 3 50VL--A

Summary of the content on the page No. 4

A09463 Fig.3 -- 50VL--A42--60UnitDimensions 4 50VL--A

Summary of the content on the page No. 5

Dashed lines show cross support B location for large basepan units. G C HVAC unit HVAC unit basepan base rails Sealing Gasket Roofcurb H F A Anchor screw Wood nailer* Flashing field supplied Roofcurb* Insulation (field supplied) Roofing material field supplied E D Cant strip field supplied A09413 SMALL/COMMON CURB *Provided with roofcurb A09090 ROOF CURB DETAIL B C SMALL SUPPLY BASE G AIR UNIT H A LARGE F BASE RETURN UNIT AIR E D UNIT PLACEMENT ON COMMON CURB A09094 A09415 SMALL OR LARGE B

Summary of the content on the page No. 6

CAUTION - NOTICE TO RIGGERS PRUDENCE - AVIS AUX MANIPULATEUR ACCESS PANELS MUST BE IN PLACE WHEN RIGGING. PANNEAUX D'ACCES DOIT ÊTRE EN PLACE POUR MANIPULATION. Use top skid as spreader bar. / Utiliser la palette du haut comme barre de répartition DUCTS MINIMUM HEIGHT: 36" (914.4 mm) HAUTEUR MINIMUM SEAL STRIP MUST BE IN BANDE SCELLANT DOIT ÊTRE PLACE BEFORE PLACING EN PLACE AVANT DE PLACER UNIT HEIGHT L'UNITÉ SUR LA BASE DE TOIT UNIT ON ROOF CURB HAUTEUR D'UNITÉ DETAIL A VOIR DÉTAIL A SEE DET

Summary of the content on the page No. 7

INSPECTION Step3—ProvideClearances The required minimum serviceclearances areshown in Fig. 2 and Prior to initial use, and at monthly intervals, all rigging shackles, 3. Adequate ventilation and outdoor air must be provided. The clevispins,andstrapsshouldbevisuallyinspectedforanydamage, outdoor fan draws air through the outdoor coil and discharges it evidence of wear, structural deformation, or cracks. Particular through the top fan grille. Be sure that the fan discharge does not attention shoul

Summary of the content on the page No. 8

Air Conditioning Contractors National Association Step6—ConnectCondensateDrain (SMACNA) and Air Conditioning Contractors Association NOTE: When installing condensate drain connection be sure to (ACCA) minimum installation standards for residential comply with local codes and restrictions. heating and airconditioning systems. Model 50VL--A disposes of condensate water through a 3/4 in. 5. Secure all ducts to building structure. Flash, weatherproof, NPT fitting which exits through the base on the

Summary of the content on the page No. 9

! CAUTION UNITCOMPONENTDAMAGEHAZARD Failure to follow this caution may result in damage to the unitbeinginstalled. 1. Make all electrical connections in accordance with NFPA70 (NEC)(latestedition)and local electricalcodes governing such wiring. In Canada, all electrical connections must be in accordance with CSA standard C22.1 Canadian Electrical Code Part 1 and applicable local codes. Refer to unit wiring diagram. 2. Use only copper conductor for connections between field--supplied electrical d

Summary of the content on the page No. 10

SPECIALPROCEDURESFOR208--VOPERATION HIGH VOLTAGE POWER LEADS ! POWER WARNING (SEE UNIT WIRING SUPPLY LABEL) ELECTRICALSHOCKHAZARD 3-PHASE SHOWN 1-PHASE USES Failure to follow this warning could result in personal TWO POWER injuryordeath. EQUIP GR LEADS FIELD-SUPPLIED FUSED DISCONNECT Before installing or servicing system, always turn off main power to system and install lockout tag. With disconnect CONTROL BOX switch open, move black wire from transformer (3/16 WHT(W1) W1 in.)(4.8 mm) terminal

Summary of the content on the page No. 11

Table1–PhysicalData--Unit50VL--A UNITSIZE 24 30 36 42 48 60 NOMINAL CAPACITY(ton) 2 2---1/2 3 3---1/2 4 5 SHIPPING WEIGHT* lb. 295 307 365 421 439 467 SHIPPING WEIGHT* (kg) 134 139 166 191 199 212 Scroll COMPRESSORS Quantity 1 REFRIGERANT(R---410A) Quantity lb 6.0 5.6 9.5 8.8 9.4 12.5 Quantity (kg) 2.7 2.5 4.3 4.0 4.3 5.7 REFRIGERANTMETERING DEVICE TXV OUTDOORCOIL Rows...Fins/in. 1...21 1...21 2...21 2...21 2...21 2...21 Face Area (sq ft) 11.9 13.6 15.4 13.6 17.5 21.4 OUTDOORFAN Nominal Cfm 2500

Summary of the content on the page No. 12

2. Repair leak following accepted practices. PRE--START--UP NOTE: Install a filter drier whenever the systemhas been opened for repair. ! WARNING 3. Add a smallcharge ofPuron (R--410A)refrigerant vaporto system and leak--test unit. ENVIRONMENTAL, FIRE, EXPLOSION, 4. Recover refrigerant from system and evacuate to 500 ELECTRICALSHOCKHAZARD micronsifno additionalleaksarefound. Failure to follow this warning could result in personal 5. Charge unit with Puron (R--410A) refrigerant, using an injuryor

Summary of the content on the page No. 13

Proceed as follows: shipped loose with vinyl caps and are located in the control box, near the interface fan board (IFB) (See Fig. 11). 1. Remove caps from low-- and high--pressure service fittings. SINGLECOOLINGFANSPEEDSET--UP(Dehumidi- 2. Using hoses with valve core depressors, attach low-- and high--pressure gauge hoses to low-- and high--pressure ficationfeaturenotused) service fittings, respectively. To change cooling speed: 3. Startunitand letrun untilsystem pressuresstabilize. 1. Remove t

Summary of the content on the page No. 14

P3 SDL Table3–ColorCodingforIndoorFanMotorLeads HIGH LOW COM QC5 QC4 QC3 Black = High Speed Orange = Med--High Speed Red = Med Speed KL KZ DCR QCR Pink = Med--Low Speed Blue = Low Speed C 07 09 0L0 08 R13 C8 R11 Q1 ALO D2 QC1 Q3 AL2 ! WARNING C9 RL C4 G1 01 ELECTRICALSHOCKHAZARD Failure to follow this warning could result in personal G2 QIL Z2 06 04 A7 R9 AB A15 injuryordeath. C0 F1 Z1 Disconnect electrical power to the unit and install lockout U1 tagbeforechangingblowerspeed. R4 RL4 C3 D5 D3 C7

Summary of the content on the page No. 15

15 Table4–DryCoilAirDelivery*-- Horizontal Discharge-- Unit50VL--A24--60 EXTERNAL STATIC PRESSURE(IN.W.C.) UNIT MOTORSPEED WIRECOLOR 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Low Blue CFM 754 650 538 429 --- --- --- --- --- Med-Low Pink CFM 851 777 675 591 475 --- --- --- --- 1 50VL-A24 Medium Red CFM 941 851 774 684 576 479 --- --- --- Med-High Orange CFM 1009 917 840 759 667 577 447 --- --- High Black CFM 1241 1167 1111 1036 969 881 818 731 640 Low Blue CFM 741 638 547 415 --- --- --- --- --- Med-Lo

Summary of the content on the page No. 16

16 50VL--A Table6–50VL--AHorizontalandDownflowDischargeWetCoilPressureDrop(IN.W.C.) STANDARDCFM(SCFM) UNIT SIZE 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 24 0.030 0.037 0.044 0.053 0.063 - - - - - - - - - - - - 30 - - - 0.053 0.063 0.072 0.081 0.105 - - - - - - - - - 36 - - - 0.055 0.060 0.090 0.100 0.110 0.140 - - - - - - - - 42 - - - - 0.045 0.050 0.060 0.065 0.075 0.080 0.090 0.094 0.110 - - - - 48 - - - - - - 0.041 0.063 0.085 0.100 0.104 0.110 0.120 0.

Summary of the content on the page No. 17

A11004 Fig.12 -- ConnectionWiringDiagram208/230--1--60 17 50VL--A

Summary of the content on the page No. 18

A11003 Fig.12Cont. -- LadderWiringDiagram208/230--1--60 18 50VL--A

Summary of the content on the page No. 19

A11010 Fig.13 -- ConnectionWiringDiagram208/230--3--60 19 50VL--A

Summary of the content on the page No. 20

A11009 Fig.13Cont. -- LadderWiringDiagram208/230--3--60 20 50VL--A


Alternative user manuals
# User manual Category Download
1 Carrier 024 User manual Air Conditioner 588
2 Carrier 09DK054-094 User manual Air Conditioner 100
3 Carrier 09DK054-084 User manual Air Conditioner 48
4 Carrier 17DA User manual Air Conditioner 26
5 Carrier 09DC User manual Air Conditioner 32
6 Carrier 040-420 User manual Air Conditioner 66
7 Carrier 17EX User manual Air Conditioner 14
8 Carrier 19 User manual Air Conditioner 17
9 Carrier 1995 User manual Air Conditioner 31
10 Carrier 09BB User manual Air Conditioner 11
11 Carrier 19DG User manual Air Conditioner 17
12 Carrier 19XRV User manual Air Conditioner 90
13 Carrier 30GA User manual Air Conditioner 32
14 Carrier 30GB User manual Air Conditioner 178
15 Carrier 30GX080-176 User manual Air Conditioner 22
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21