Carrier 50HE003-006 user manual

User manual for the device Carrier 50HE003-006

Device: Carrier 50HE003-006
Category: Air Conditioner
Manufacturer: Carrier
Size: 2.19 MB
Added : 8/28/2013
Number of pages: 72
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier 50HE003-006. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier 50HE003-006.

For your convenience

If looking through the Carrier 50HE003-006 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier 50HE003-006 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier 50HE003-006 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier 50HE003-006 User manual - Online PDF
Advertisement
« Page 1 of 72 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier 50HE003-006 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier 50HE003-006. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

50HJ004---007
50HE003---006
Single---Package Rooftop Electric Cooling
UnitswithOptional Electric Heat
Installation Instructions
TABLEOFCONTENTS SAFETYCONSIDERATIONS
Page Installation and servicing of air-conditioning equipment can be
hazardous due to system pressure and electrical components.
SAFETY CONSIDERATIONS ........................ 1
Onlytrainedand qualifiedservicepersonnelshould install,repair,
INSTALLATION .................................. 1
orserviceair-conditioning equipment.
Step1--

Summary of the content on the page No. 2

Step1 —ProvideUnitSupport NOTE: Horizontal units may be installed on a roof curb if required. RoofCurb AlternateUnitSupport Assemble and install accessory roof curb in accordance with instructions shipped with curb. (See Fig. 2.) Install insulation, When the curb or adapter cannot be used, support unit with cantstrips,roofing felt,and counter flashing as shown. Ductwork sleeper rails using unit curb or adapter support area. If sleeper must be attached to curb, not to the unit. Ifelectriccontrolp

Summary of the content on the page No. 3

DALT ROOFCURB UNIT CONNECTOR ACCESSORY A BC DRAIN GAS POWER CONTROL ACCESSORY SIZE PKG.ACCY. POWER HOLE 1 -2 3 CRRFCURB001A01 CRBTMPWR001A01 3 / [19] NPT / 4 4 [356] 50HJ004-007 [19] NPT 1 CRBTMPWR002A01 1 / [31.7] 4 2 -0 50HE003-006 CRRFCURB002A01 11 3 1 1 1 1 -9 /16 1 -4 1 /4 /2 /2 [610] /2 3 CRBTMPWR003A01 /4 [19] NPT [551] [406] [44.5] [12.7] [12.7] [12.7] NPT 3 / 4 NOTES: 1 CRBTMPWR004A01 1 / [31.7] 4 [19] NPT 1. Roof curb accessory is shipped disassembled. 2. Insulated panels. 3. Dimen

Summary of the content on the page No. 4

Step4 —RigandPlaceUnit Inspect unit for transportation damage, and file any claim with transportation agency. Keep unit upright and do not drop. Spreader bars are not required if top crating is left on unit, and rollers may be used to move unit across a roof. Level by using unit frame as a reference.See Table1, 2 and Fig.6 foradditional information.Operating weightisshown in Table1,2 and Fig.6. Lifting holes are provided in base rails as shown in Fig. 7. Refer to rigging instructionson unit. CON

Summary of the content on the page No. 5

NOTES: 1. Place unit on curb as close as possible to the duct end. 2. Dimension in ( ) is in millimeters. 3. Hook rigging shackles through holes in base rail as shown in detail "A." Holes in base rails are centered around the unit center of gravity. Use wooden top skid when rigging to prevent rigging straps from damaging unit. 4. Weights include base unit without economizer. See Table 1 for unit operating weights with accessory economizer. TM 5. Weights include base unit without

Summary of the content on the page No. 6

6 50HE,HJ C06156 Fig.8 --- 50HJ004--007 BaseUnitDimensions

Summary of the content on the page No. 7

7 C06157 Fig.9 --- 50HE003--006 BaseUnitDimensions 50HE,HJ

Summary of the content on the page No. 8

Step5 —MakeElectricalConnections NOTE: For wire runs up to 50 ft, use no. 18 AWG (American WireGauge)insulatedwire(35_Cminimum).For50to75ft,use no.16 AWG insulated wire(35_C minimum).Forover75 ft,use ! WARNING no. 14 AWG insulated wire (35_C minimum). All wire larger than no. 18 AWG cannot be directly connected to the thermostat ELECTRICALSHOCKHAZARD and willrequireajunction box and spliceatthethermostat. Failure to follow this warning could result in personal 1. Connectthermostat wiresto screwt

Summary of the content on the page No. 9

Table1—PhysicalData50HJ BASEUNIT50HJ 004 005 006 007 NOMINAL CAPACITY 3 4 5 6 OPERATINGWEIGHT (lb) Unit 435 445 465 540 Humidi-MiZer™ Adaptive Dehumidification System 15 23 25 29 EconoMi$er IV 50 50 50 50 Roof Curb 115 115 115 115 COMPRESSOR Scroll Quantity 1 1 1 1 Oil (oz) 42 53 50 60 REFRIGERANT TYPE R-22 Expansion Device Acutrol™ MeteringDevice OperatingCharge (lb-oz) StandardUnit 5-8 10-2 10-0 12- 8 Unit With Humidi-Mizer Adaptive Dehumidification System 12-5 18-8 20-5 23-14 CONDENSERFAN Pro

Summary of the content on the page No. 10

Table2—PhysicalData50HE BASEUNIT50HE 003 004 005 006 NOMINAL CAPACITY 2 3 4 5 OPERATINGWEIGHT (lb) Unit 435 445 465 635 Humidi-MiZer™ Adaptive Dehumidification System 13 15 23 25 EconoMi$er IV 50 50 50 50 Roof Curb 115 115 115 115 COMPRESSOR Scroll Quantity 1 1 1 1 Oil (oz) 25 42 56 53 REFRIGERANT TYPE R-22 Expansion Device Acutrol™ MeteringDevice OperatingCharge (lb-oz) StandardUnit 5---3 7---11 8---8 12---11 Unit With Humidi-Mizer Adaptive Dehumidification System 10---2 14---0 14---13 21---0 C

Summary of the content on the page No. 11

208/230-3-60 460-3-60 208/230-1-60 (SIZES 006 AND 007) 575-3-60 575-3-60 (SIZES 004 AND 005) (SIZES 006 AND 007) 460-3-60 208/230-3-60 (SIZES 004 AND 005) (SIZES 004 AND 005) LEGEND C— Contactor COMP — Compressor IFC — Indoor (Evaporator) Fan Contactor NEC — National Electrical Code TB — Terminal Block C06158 Fig.12 --- PowerWiring Connections LOW VOLTAGE INTEGRATED GAS UNIT CONNECTIONS CONTROLLER (IGC) C06125 Fig.13 --- Field ControlWiring Raceway 11 50HE,HJ

Summary of the content on the page No. 12

12 50HE,HJ Table3—ElectricalData--50HE VOLTAGERANGE COMPRESSOR(each) OUTDOORFAN ELECTRIC HEAT POWERSUPPLY * DISCONNECTSIZE Nominal IFM CRHEATER Actual UNITSIZE IFM CONV ---------A00 V---Ph---Hz Min Max QTY RLA LRA QTY FLA FLA FLA MCA FLA LRA MOCP** TYPE OUTLET or B00 kW† NONE —/ — —/— 16.3/16.3 20/20 16/16 69/69 001A00 3.3/ 4.0 15.9/18.3 22.4/25.4 25/30 21/23 69/69 NO 187 254 1 10.9 63.0 1 0.7 2.0 002A00 4.9/ 5.8 23.5/27.1 31.8/36.4 35/40 29/33 69/69 003B00 6.5/ 8.0 31.4/36.3 41.8/47.8 45/50 38/

Summary of the content on the page No. 13

13 Table3—ElectricalData--50HE(cont) VOLTAGERANGE COMPRESSOR(each) OUTDOORFAN ELECTRIC HEAT POWERSUPPLY * DISCONNECTSIZE Nominal IFM CRHEATER Actual UNITSIZE IFM CONV ---------A00 V---Ph---Hz Min Max QTY RLA LRA QTY FLA FLA FLA MCA FLA LRA MOCP** TYPE OUTLET or B00 kW† NONE — — 9.4 15.0 9.0 60.0 006A00 5.5 7.2 12.3 15.0 11.0 60.0 NO 414 508 1 5.1 39.0 1 0.4 2.6 007A00 8.1 10.6 16.5 20.0 15.0 60.0 008A00 10.6 13.8 20.5 25.0 19.0 60.0 009A00 12.9 16.8 24.3 25.0 22.0 60.0 460---3---60 HS NONE — — 1

Summary of the content on the page No. 14

14 50HE,HJ Table3—ElectricalData--50HE(cont) VOLTAGE COMPRESSOR(each) OUTDOORFAN ELECTRIC HEAT POWERSUPPLY DISCONNECTSIZE RANGE UNIT NOMINAL IFM CONV IFM CRHEATER SIZE V---PH---Hz TYPE OUTLET FLA ------A00 or Min Max QTY RLA LRA QTY FLA ActualkW{ FLA MCA MOCP** FLA LRA B00 NONE —/— —/— 32.7/32.7 40/40 32/32 130/130 001A00 3.3/ 4.0 15.9/18.3 32.7/32.7 40/40 32/32 130/130 003B00 6.5/ 8.0 31.4/36.3 45.4/51.4 50/60 42/47 130/130 NO 197 254 1 21.0 115.0 1 1.5 4.9 002,002 9.8/ 11.6 46.9/54.2 64.8/73.8

Summary of the content on the page No. 15

15 Table3—ElectricalData--50HE(cont) VOLTAGE COMPRESSOR(each) OUTDOORFAN ELECTRIC HEAT POWERSUPPLY DISCONNECTSIZE RANGE UNIT NOMINAL IFM CONV IFM CRHEATER SIZE V---PH---Hz TYPE OUTLET FLA ------A00 or Min Max QTY RLA LRA QTY FLA ActualkW{ FLA MCA MOCP** FLA LRA B00 NONE —/— —/— 39.4/39.4 50/50 38/38 187/187 002A00 4.9/ 5.8 23.5/27.1 39.4/42.1 50/50 38/39 187/187 003B00 6.5/ 8.0 31.4/36.3 47.5/53.6 50/60 44/49 187/187 NO 187 254 1 25.0 150.0 1 1.5 6.6 02,002 8.7/ 11.6 46.9/54.2 66.9/76.0 70/80 62

Summary of the content on the page No. 16

16 50HE,HJ Table3—ElectricalData--50HE(cont) VOLTAGE COMPRESSOR(each) OUTDOORFAN ELECTRIC HEAT POWERSUPPLY DISCONNECTSIZE RANGE UNIT NOMINAL IFM CONV IFM CRHEATER SIZE V---PH---Hz TYPE OUTLET FLA ------A00 or Min Max QTY RLA LRA QTY FLA ActualkW{ FLA MCA MOCP** FLA LRA B00 NONE — — 13.9 20.0 14.0 92.0 006A00 5.5 7.2 13.9 20.0 14.0 92.0 008A00 10.6 13.8 20.5 25.0 19.0 92.0 NO 414 508 1 8.4 70.0 1 0.8 2.6 009A00 12.9 16.8 24.3 25.0 22.0 92.0 008,008 21.1 27.7 37.8 40.0 35.0 92.0 008,009 23.4 30.1

Summary of the content on the page No. 17

17 Table4—ElectricalData--50HJ VOLTAGE COMPRESSOR(each) OUTDOORFAN ELECTRIC HEAT POWERSUPPLY * DISCONNECTSIZE RANGE UNIT NOMINAL CONV IFM IFMTYPE CRHEATER SIZE V---PH---Hz OUTLET FLA Actual Min Max QTY RLA LRA QTY FLA ------A00 or FLA MCA FLA LRA MOCP** kW† B00 — —/ — —/ — 25.6/ 25.6 30/ 30 25/ 25 101/ 101 001 3.3/ 4.0 15.9/ 18.3 26.0/ 29.0 30/ 30 25/ 27 101/ 101 002 4.9/ 5.8 23.5/ 27.1 35.5/ 40.0 40/ 40 33/ 37 101/ 101 NO 187 254 1 16 88 1 0.7 4.9 003 6.5/ 8.0 31.4/ 36.3 45.4/ 51.4 50/ 50 42/ 4

Summary of the content on the page No. 18

18 50HE,HJ Table4—ElectricalData--50HJ(cont) VOLTAGE COMPRESSOR(each) OUTDOORFAN ELECTRIC HEAT POWERSUPPLY * DISCONNECTSIZE RANGE UNIT NOMINAL CONV IFM IFMTYPE CRHEATER SIZE V---PH---Hz OUTLET FLA Actual Min Max QTY RLA LRA QTY FLA ------A00 or FLA MCA FLA LRA MOCP** kW† B00 — — — 9.0 20 9 46 006 5.5 7.2 11.8 20 11 46 NO 414 508 1 5.1 39 1 0.4 2.2 007 8.1 10.6 16.0 20 15 46 008 10.6 13.8 20.0 25 18 46 009 12.9 16.8 23.8 25 22 46 STD — — — 11.7 20 11 48 006 5.5 7.2 15.1 20 13 48 YES 414 508 1 5.1

Summary of the content on the page No. 19

19 Table4—ElectricalData--50HJ(cont) VOLTAGERANGE COMPRESSOR(EACH) OUTDOORFAN ELECTRIC HEAT POWERSUPPLY DISCONNECTSIZE CRHEATER UNIT NOMINAL CONV IFM IFMTYPE Min Max QTY RLA LRA QTY FLA ------A00 or ActualkW{ FLA MCA MOCP** FLA LRA SIZE V---PH---Hz OUTLET FLA B00 — —/— —/— 35.2/ 35.2 45/ 45 34/ 34 139/ 139 001 3.3/ 4.0 15.9/ 18.3 35.2/ 35.2 45/ 45 34/ 34 139/ 139 003 6.5/ 8.0 31.4/ 36.3 45.4/ 51.4 50/ 60 42/ 47 139/ 139 NO 197 254 1 23.7 126 1 0.7 4.9 002+002 9.8/ 11.6 46.9/ 54.2 64.8/ 73.8 70/

Summary of the content on the page No. 20

20 50HE,HJ Table4—ElectricalData--50HJ(cont) VOLTAGERANGE COMPRESSOR(EACH) OUTDOORFAN ELECTRIC HEAT POWERSUPPLY DISCONNECTSIZE CRHEATER UNIT NOMINAL CONV IFM IFMTYPE Min Max QTY RLA LRA QTY FLA ------A00 or ActualkW{ FLA MCA MOCP** FLA LRA SIZE V---PH---Hz OUTLET FLA B00 — —/— —/— 46.3/ 46.3 60/ 60 45/ 45 216/ 216 002 4.9/ 5.8 23.5/ 27.1 46.3/ 46.3 60/ 60 45/ 45 216/ 216 003 6.5/ 8.0 31.4/ 36.3 50.3/ 56.3 60/ 60 46/ 52 216/ 216 NO 187 254 1 28.8 169 1 1.5 8.8 002+002 8.7/ 11.6 46.9/ 54.2 69.7/ 7


Alternative user manuals
# User manual Category Download
1 Carrier 024 User manual Air Conditioner 588
2 Carrier 09DK054-094 User manual Air Conditioner 100
3 Carrier 09DK054-084 User manual Air Conditioner 48
4 Carrier 17DA User manual Air Conditioner 26
5 Carrier 09DC User manual Air Conditioner 32
6 Carrier 040-420 User manual Air Conditioner 66
7 Carrier 17EX User manual Air Conditioner 14
8 Carrier 19 User manual Air Conditioner 17
9 Carrier 1995 User manual Air Conditioner 31
10 Carrier 09BB User manual Air Conditioner 11
11 Carrier 19DG User manual Air Conditioner 17
12 Carrier 19XRV User manual Air Conditioner 90
13 Carrier 30GA User manual Air Conditioner 32
14 Carrier 30GB User manual Air Conditioner 178
15 Carrier 30GX080-176 User manual Air Conditioner 22
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21