Carrier 48TF004-007 user manual

User manual for the device Carrier 48TF004-007

Device: Carrier 48TF004-007
Category: Air Conditioner
Manufacturer: Carrier
Size: 1.27 MB
Added : 12/5/2013
Number of pages: 52
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier 48TF004-007. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier 48TF004-007.

For your convenience

If looking through the Carrier 48TF004-007 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier 48TF004-007 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier 48TF004-007 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier 48TF004-007 User manual - Online PDF
Advertisement
« Page 1 of 52 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier 48TF004-007 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier 48TF004-007. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

48TF004-007
Single-Package Rooftop
Heating/Cooling Units
Installation, Start-Up, and
Service Instructions
CONTENTS
Page
Disconnect gas piping from unit when leak
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1
1
testing at pressure greater than / psig.
2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-35
1
Pressures greater than / psig will cause
2
Step 1 — Provide Unit Support . . . . . . . . . . . . . . . . . . . 1
gas valve damage resulting i

Summary of the content on the page No. 2

Fig. 1 — Horizontal Conversion Panels Curb should be level. Unit leveling tolerances are shown in When using the standard side drain connection, make sure Fig. 3. This is necessary for unit drain to function properly. Re- the plug (Red) in the alternate bottom connection is tight before fer to Accessory Roof Curb Installation Instructions for addi- installing the unit. tional information as required. To use the bottom drain connection for a roof curb installa- SLAB MOUNT (Horizontal Units Only)

Summary of the content on the page No. 3

3 NOTES: 7. Direction of airflow. ROOF CURB 1. Roof curb accessory is shipped disassembled. A UNIT SIZE ACCESSORY 8. Connector packages CRBTMPWR001A00 and 002A00 are for thru-the- 2. Insulated panels. curb connections. Packages CRBTMPWR003A00 and 004A00 are for 1′-2″ 3. Dimensions in [ ] are in millimeters. CRRFCURB001A00 thru-the-bottom connections. [356] 4. Roof curb, galvanized steel. 48TF004-007 5. Attach ductwork to curb (flanges of duct rest on curb). 2′-0″ CRRFCURB002A00 6. Service cleara

Summary of the content on the page No. 4

Flue gas can deteriorate building materials. Orient unit such that flue gas will not affect building materials. Adequate combustion-air space must be provided for proper operation of this equipment. Be sure that installation complies MAXIMUM ALLOWABLE DIFFERENCE (in.) with all local codes and Section 5.3, Air for Combustion and Ventilation, NFGC (National Fuel Gas Code), and ANSI A-B B-C A-C (American National Standards Institute) Z223.1, and NFPA 0.5 1.0 1.0 (National Fire Protection Associatio

Summary of the content on the page No. 5

Table 1 — Physical Data — 48TF004-007 UNIT SIZE 48TF E/F/M/N004 D/E/F/L/M/N005 D/E/F/L/M/N006 D/E/F007 NOMINAL CAPACITY (tons) 3456 OPERATING WEIGHT (lb) Unit Al/Al* 460 470 490 565 Al/Cu* 465 476 497 576 Cu/Cu* 468 482 505 587 Economizer Durablade 34 34 34 34 EconoMi$er 47 47 47 47 Roof Curb† 115 115 115 115 COMPRESSOR Reciprocating Scroll Quantity 1111 No. Cylinders (per Circuit) 2222 Oil (oz) 50 50 50 54 REFRIGERANT TYPE R-22 Expansion Device Acutrol™ Metering Device Operating Charge (lb-oz)

Summary of the content on the page No. 6

Table 1 — Physical Data — 48TF004-007 (cont) UNIT SIZE 48TF E/F/M/N004 D/E/F/L/M/N005 D/E/F/L/M/N006 D/E/F007 FURNACE SECTION Rollout Switch Cutout Temp (F)†† 195 195 195 195 Burner Orifice Diameter (in. ...drill size) Natural Gas Std TFD — .113...33 .113...33 .113...33 TFE .113...33 .113...33 .113...33 .113...33 TFF .113...33 .129...30 .129...30 .129...30 TFL — .102...38 .102...38 — TFM .102...38 .102...38 .102...38 — TFN .102...38 .116...32 .116...32 — Liquid Propane Alt TFD — .089...43 .089..

Summary of the content on the page No. 7

7 BOTTOM POWER CHART, STD UNIT DURABLADE ECONOMI$ER (A) (B) (C) (D) “A” THESE HOLES REQ’D FOR USE WEIGHT ECONOMIZER WEIGHT WEIGHT CORNER WEIGHT CORNER WEIGHT CORNER WEIGHT CORNER WEIGHT UNIT PANEL WITH ACCESSORY PACKAGES — LENGTH Lbs Kg Lbs Kg Lbs Kg Lbs Kg Lbs Kg Lbs Kg Lbs Kg 1 3 CRBTMPWR001A00, 3A00 ( / ″, / ″) 2 4 3 48TFN,TFM,TFF,TFE004 460 209 140 63.5 105 47.6 159 72.1 56 25.4 1′-10 / ″ [568.0] 8 3 THREADED REQ’D HOLE 48TFN,TFM,TFL,TFF,TFE,TFD005 470 213 142 64.4 106 48.1 162 73.5 60 27.2

Summary of the content on the page No. 8

Step 7 — Make Electrical Connections Unit cabinet must have an uninterrupted, unbroken electri- cal ground to minimize the possibility of personal injury if an electrical fault should occur. This ground may consist of electrical wire connected to unit ground lug in control com- partment, or conduit approved for electrical ground when installed in accordance with NEC (National Electrical Code), ANSI/NFPA, latest edition, and local electrical codes. Do not use gas piping as an electrical ground. F

Summary of the content on the page No. 9

208/230-3-60 208/230-1-60 460-3-60 (SIZE 007 ONLY) 575-3-60 208/230-3-60 (SIZE 007 ONLY) 575-3-60, 460-3-60 (SIZES 004-006) LEGEND C— Contactor COMP — Compressor NEC — National Electrical Code TB — Terminal Block Fig. 9 — Power Wiring Connections RACEWAY LOW VOLTAGE INTEGRATED GAS UNIT CONNECTIONS CONTROLLER (IGC) LEGEND AHA — Adjustable Heat Anticipator Field Wiring Factory Wiring NOTES: 1. Connect Y2 when unit is equipped with an economizer. HOLE IN END PANEL (HIDDEN) 2. Connect W2 when unit i

Summary of the content on the page No. 10

Table 2 — Electrical Data VOLTAGE COMPRESSOR OFM POWER DISCONNECT COMBUSTION UNIT NOMINAL IFM IFM RANGE (ea) (ea) SUPPLY SIZE* FAN MOTOR 48TF V-Ph-Hz TYPE FLA FLA Min Max RLA LRA Qty Hp FLA MCA MOCP† FLA LRA Std 3.5 24.5/24.5 30/30 23/23 106/106 1 208/230-1-60 187 254 16.2 96.0 1 / 1.4 .6 4 Alt 4.9 26.6/26.6 35/35 26/26 111/111 Std 3.5 17.7/17.7 25/25 17/17 85/85 1 208/230-3-60 Alt 187 254 10.2 75.0 1 / 1.4 4.9 .6 19.1/19.1 25/25 19/19 90/90 4 High 5.2 19.4/19.4 25/25 19/19 109/109 004 Std 1.3 7

Summary of the content on the page No. 11

5. Place hood on front of outdoor air opening panel. See Step 8 — Make Outdoor-Air Adjustments and Fig. 13 for hood details. Secure top of hood with the Install Outdoor-Air Hood 4 screws removed in Step 3. See Fig. 14. MANUAL OUTDOOR-AIR DAMPER — The outdoor-air 6. Remove and save 6 screws (3 on each side) from sides of hood and screen are attached to the basepan at the bottom of the manual outdoor-air damper. the unit for shipping. 7. Align screw holes on hood with screw holes on side of Assemb

Summary of the content on the page No. 12

OPTIONAL DURABLADE ECONOMIZER — The op- tional economizer hood assembly is packaged and shipped in the filter section. Damper blades and control boards are in- stalled at the factory and the economizer is shipped in the verti- cal discharge position. NOTE: Horizontal discharge block-off plate is shipped with the air hood package. If unit is to be used for vertical discharge application, discard this plate. Assembly: 1. Determine if ventilation air is required in building. If so, determine minimu

Summary of the content on the page No. 13

3 75 80 198818A TR1 1 ENTHALPY CONTROL 2 85 60 65 70 50 CONTACTS SHOWN IN HIGH ENTHALPY OR UNPOWERED STATE CONTACT RATINGS: 1.5A RUN, 3.5A IN RUSH AT 24VAC 3 mA MIN. AT 11 VDC CW–SETPOINTS–CCW DAMPER CLOSED DAMPER OPEN OUTDOOR TEMP. °F TR 24VAC 55 REV. B TR B C S O D S 5 1 2 3 MINIMUM 4 POSITION T T1 OPEN P P1 D C B A % H 90 U 70 M I D 60 I 30 T Y 10 BLOCK-OFF PLATE Fig. 19 — Horizontal Discharge Block-Off Plate U-SHAPED ECONOMIZER CONTROL ECONOMIZER ECONOMIZER TOP HOLE (NOT BOARD PLUG MOTOR S

Summary of the content on the page No. 14

ECONOMI$ER CONTROLLER PLUG GEAR-DRIVEN DAMPER LEGEND OAT — Outdoor-Air Thermostat OUTDOOR AIR TEMPERATURE NOTE: See unit wiring diagram for details. SENSOR Fig. 23 — Wiring Connections for Outdoor-Air Thermostat ACTUATOR 0.90 BAROMETRIC RELIEF DAMPERS 0.80 Fig. 25 — EconoMi$er Component Locations 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 100 200 300 400 500 600 700 800 CFM Fig. 24 — Durablade Economizer Barometric Relief Damper Characteristics OPTIONAL ECONOMI$ER — See Fig. 25 for EconoMi$er compo

Summary of the content on the page No. 15

5. Slide the outdoor-air inlet screens into the screen track on the hood side panels. While holding the screens in place, fasten the screen retainer to the hood using the screws provided. Repeat the process for the barometric exhaust air screen. Do not attach completed (Fig. 29) hood as- sembly to unit at this time. 6. Slide the EconoMi$er assembly into the rooftop unit. See Fig. 30 and 31. NOTE: Be sure to engage rear EconoMi$er flange under tabs in return-air opening of the unit base. See Fig

Summary of the content on the page No. 16

LEGEND OAT — Outdoor-Air Temperature RAT — Return-Air Temperature Fig. 32 — EconoMi$er Wiring ECONOMI$ER BROWN TEMP CONTROLLER VIOLET TEMP OUTDOOR OAT AIR COM WHITE SENSOR COM OUT RED PWR OAH -15 V BROWN TEMP RAT VIOLET RETURN TEMP COM AIR WHITE COM SENSOR RAH OUT RED +15 V PWR CO SENSOR 2 (+) V+ 24 CO 2 CO COM 2 COM VAC DAT COM SUPPLY AIR TEMPERATURE SENSOR REM POT PINK COM TEMP LED VIOLET TEMP COM Fig. 33 — EconoMi$er Sensor Wiring 16

Summary of the content on the page No. 17

TO FUSED DISCONNECT RED GRAY RED YEL BLU GRAY H1 H2 H1 H3 H2 H4 X4 X2 X3 X1 X4 X2 X3 X1 FIELD SUPPLIED WIRING SECONDARY SECONDARY 230VAC 230VAC BLACK BLACK COMPRESSOR 1 OR CONTACTOR LT. BLUE 11 21 3 B 6 9 230VAC BLACK BROWN 13 23 FAN 1 R1 2 3-PIN 5 8 24 VAC C1 CONNECTOR PLUG GREEN/ YELLOW 4 A 1 7 4-PIN CONNECTOR 2 x 4 IN. BLUE ORANGE 1 PLUG HANDY BOX YELLOW L1 2 BLACK L1 1 1 L2 BLUE L2 BROWN 22 3 GND GREEN GND 33 BLACK BLACK 44 BLUE 230 VAC LT. BLUE GREEN 1 PHASE B 3 6 9 BLACK R2 BROWN F

Summary of the content on the page No. 18

Ventilation Air (Minimum Position Set Up) — If ventilation air is not required, proceed to Step 5. If ventilation air is re- quired, perform the following: 1. The indoor fan must be on to set the ventilation air. Either put the thermostat in the continuous fan mode or SUPPLY AIR jumper the R and G terminals at the rooftop unit con- TEMPERATURE nection board. SENSOR MOUNTING 2. Locate the minimum position (MIN POS) potentiome- LOCATION ter. Turn the potentiometer full CCW to fully close the outdo

Summary of the content on the page No. 19

To align fan and motor pulleys: Step 9 — Adjust Evaporator-Fan Speed — Ad- just evaporator-fan rpm to meet jobsite conditions. Table 5 1. Loosen fan pulley setscrews. shows fan rpm at motor pulley settings. Table 6 shows motor 2. Slide fan pulley along fan shaft. performance. See Table 7 for Accessory/FIOP Static Pressure. Make angular alignment by loosening motor from Refer to Tables 8-29 to determine fan speed settings. mounting. DIRECT-DRIVE MOTORS — The evaporator-fan motor To adjust belt t

Summary of the content on the page No. 20

Table 5 — Fan Rpm at Motor Pulley Settings* MOTOR PULLEY TURNS OPEN UNIT 48TF 1 1 1 1 1 1 0 / 11/ 22/ 33/ 44/ 55/ 6 2 2 2 2 2 2 004† 1000 976 952 928 904 880 856 832 808 784 760 — — 004** 1455 1423 1392 1360 1328 1297 1265 1233 1202 1170 1138 1107 1075 005† 1185 1150 1115 1080 1045 1010 975 940 905 870 835 — — 005** 1455 1423 1392 1360 1328 1297 1265 1233 1202 1170 1138 1107 1075 006† 1300 1260 1220 1180 1140 1100 1060 1020 980 940 900 — — 006** 1685 1589 1557 1525 1493 1460 1428 1396 1364 1332


Alternative user manuals
# User manual Category Download
1 Carrier 48TF004-007 User manual Heat Pump 0
2 Carrier 024 User manual Air Conditioner 588
3 Carrier 09DK054-094 User manual Air Conditioner 100
4 Carrier 09DK054-084 User manual Air Conditioner 48
5 Carrier 17DA User manual Air Conditioner 26
6 Carrier 09DC User manual Air Conditioner 32
7 Carrier 040-420 User manual Air Conditioner 66
8 Carrier 17EX User manual Air Conditioner 14
9 Carrier 19 User manual Air Conditioner 17
10 Carrier 1995 User manual Air Conditioner 31
11 Carrier 09BB User manual Air Conditioner 11
12 Carrier 19DG User manual Air Conditioner 17
13 Carrier 19XRV User manual Air Conditioner 90
14 Carrier 30GA User manual Air Conditioner 32
15 Carrier 30GB User manual Air Conditioner 178
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21