Carrier 48AW user manual

User manual for the device Carrier 48AW

Device: Carrier 48AW
Category: Air Conditioner
Manufacturer: Carrier
Size: 6.67 MB
Added : 12/5/2013
Number of pages: 118
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier 48AW. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier 48AW.

For your convenience

If looking through the Carrier 48AW user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier 48AW on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier 48AW to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier 48AW User manual - Online PDF
Advertisement
« Page 1 of 118 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier 48AW but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier 48AW. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

48AJ,AK,AW,AY020-060
with Reciprocating Compressor
48EJ,EK,EW,EY024-068
Single Package Rooftop Units
Electric Cooling/Gas Heating
Installation, Start-Up and
Service Instructions
CONTENTS Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloth for unbrazing operations. Have
Page
fire extinguishers available for all brazing operations.
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 2

ROOF CURB — For vertical discharge units, assemble or in- When unit is located adjacent to public walkways, flue assem- stall accessory roof curb in accordance with instructions bly must be at least 7 ft above grade. shipped with this accessory. See Fig. 1-4. Install insulation, ROOF MOUNT — Check building codes for weight distribu- cant strips, roofing, and counter flashing as shown. Ductwork tion requirements. See Fig. 17. Unit operating weight is shown can be installed to roof curb before uni

Summary of the content on the page No. 3

3 Fig. 1 — Roof Curb — 48AJ,AK020-030 and 48EJ,EK024-034 Units

Summary of the content on the page No. 4

4 Fig. 2 — Roof Curb — 48AJ,AK034-050 and 48EJ,EK038-048 Units

Summary of the content on the page No. 5

5 Fig. 3 — Roof Curb — 48AJ,AK060 and 48EJ,EK054-068 Units

Summary of the content on the page No. 6

6 NOTES: 1. Unless otherwise specified, all dimensions are to outside of part. 2. Seal strip to be placed covering reference holes. 3. Phantom lines represent seal strip. Total length required is 75 linear ft. 4. If existing seal strip around roof curb seems damaged, replace it. Total length required is 62 linear ft. 5. Five crossrails are field located per dimensions shown and secured using self-tapping screws. 6. 48A and 48E series units will overhang existing “DD” or “DF” roof curbs by 2.98 ″

Summary of the content on the page No. 7

7 NOTES: OPERATING CORNER WEIGHT (lbs) 1. Weights include economizer (standard). A B UNIT SIZE WEIGHT* (ft-in.) (ft-in.) (lbs) 1234 2. Center of Gravity. 3 3 48AJ/AK (Low Heat) 020 5142 6- 0 / 3-6 / 1082 1174 1502 1384 8 16 3. Do not locate adjacent units with flue discharge facing economizer 5 11 48AJ (High Heat) 020 5222 6- 1 / 3-6 / 1126 1194 1494 1408 inlet. 16 16 Min Clearances to be: 5 48AJ/AK (Low Heat) 025 5228 5- 9 / 3-8 1103 1103 1511 1511 8 Adjacent Units: 15 ′-0 ″ [4572]. 3 5 48AJ (H

Summary of the content on the page No. 8

8 NOTES: OPERATING CORNER WEIGHT (lbs) 1. Weights include economizer (standard). A B UNIT SIZE WEIGHT* (ft-in.) (ft-in.) (lbs) 12 34 2. Center of Gravity. 11 7 48AJ/AK (Low Heat) 035 6004 7-8 / 3-10 / 1380 1209 1595 1820 16 8 3. Do not locate adjacent units with flue discharge facing economizer 1 3 48AJ (High Heat) 035 6164 7-10 / 3-11 / 1447 1251 1607 1859 inlet. 8 16 Min Clearances to be: 5 7 48AJ/AK (Low Heat) 040 6514 7-5 / 3-10 / 1442 1264 1779 2030 16 8 Adjacent Units: 15 ′-0 ″ [4572]. 13

Summary of the content on the page No. 9

9 NOTES: 5. Bottom ducts designed to be attached to accessory roof curb. If unit is mounted BASE UNIT WEIGHTS 1. Weights include economizer (standard). on dunnage, it is recommended the ducts must be supported by cross braces as (See Note 6) lbs (kg) done on accessory roof curb. 2. Center of Gravity. 6. Base unit weights include outdoor air hoods and filters (indoor fan motor is not 060 included). Add indoor motor, FIOPs and accessories for total operating weight. 48AJD/AKD 8930 (4051) 3. Do not

Summary of the content on the page No. 10

10 NOTES: OPERATING CORNER WEIGHT (lbs) 1. Weights include economizer (standard). A B UNIT SIZE WEIGHT* (ft-in.) (ft-in.) (lbs) 1234 2. Center of Gravity. 3 3 48AW/AY (Low Heat) 020 5182 6- 0 / 3-6 / 1090 1183 1514 1395 8 16 3. Do not locate adjacent units with flue discharge facing economizer 5 11 48AW (High Heat) 020 5262 6- 1 / 3-6 / 1134 1203 1505 1419 inlet. 16 16 Min Clearances to be: 5 48AW/AY (Low Heat) 025 5268 5- 9 / 3-8 1111 1111 1523 1523 8 Adjacent Units: 15 ′-0 ″ [4572]. 1 5 48AW (

Summary of the content on the page No. 11

11 NOTES: OPERATING CORNER WEIGHT (lbs) 1. Weights include economizer (standard). A B UNIT SIZE WEIGHT* (ft-in.) (ft-in.) (lbs) 1234 2. Center of Gravity. 11 7 48AW/AY (Low Heat) 035 6044 7- 8 / 3-10 / 1389 1217 1606 1832 16 8 3. Do not locate adjacent units with flue discharge facing economizer inlet. 1 3 48AW (High Heat) 035 6204 7-10 / 3-11 / 1456 1259 1617 1871 8 16 Min Clearances to be: Adjacent Units: 15 ′-0 ″ [4572]. 11 7 48AW/AY (Low Heat) 040 6554 7- 3 / 3-10 / 1451 1271 1790 2042 16 8

Summary of the content on the page No. 12

12 NOTES: 5. Base unit weights include outdoor air hoods and filters (indoor fan motor is not BASE UNIT WEIGHTS 1. Weights include economizer (standard). included). Add indoor motor, FIOPs and accessories for total operating weight. (See Note 6) lbs (kg) 6. VAV motor weights include indoor motor, VFD, compressor electric unloaders, VFD 2. Center of Gravity. 060 transducer and associated wiring. 7. Dimensions are in inches [mm]. 48AWD/AYD 8970 (4069) 3. Do not locate adjacent units with flue dis-

Summary of the content on the page No. 13

13 NOTES: 1. Weights include economizer (standard). 2. Center of Gravity. 3. Do not locate adjacent units with flue discharge facing economizer inlet. Min Clearances to be: Adjacent Units: 15 ′-0 ″ [4572]. Top of Units: No Overhang. Condenser Coil: 4 ′-0 ″ [1219]. Economizer Side: 6 ′-0 ″ [1829]. Heat Side: 4 ′-0 ″ [1219]. Filter Access Side: 10 ′-0 ″ [3048]. (For removal of evaporator coil.) 4. For smaller service and operational clearances contact Carrier Appli- cation Engineering Department.

Summary of the content on the page No. 14

14 NOTES: 1. Weights include economizer (standard). 2. Center of Gravity. 3. Do not locate adjacent units with flue discharge facing economizer inlet. Min Clearances to be: Adjacent Units: 15 ′-0 ″ [4572]. Top of Units: No Overhang. Condenser Coil: 4 ′-0 ″ [1219]. Economizer Side: 6 ′-0 ″ [1829]. Heat Side: 4 ′-0 ″ [1219]. Filter Access Side: 10 ′-0 ″ [3048]. (For removal of evaporator coil.) 4. For smaller service and operational clearances contact Carrier Appli- cation Engineering Department.

Summary of the content on the page No. 15

15 NOTES: BASE UNIT WEIGHTS CENTER OF GRAVITY 1. Weights include economizer (standard). % OF TOTAL WEIGHT (See Note 6) lbs (kg) AT EACH CORNER UNIT SIZE Inches Millimeters 2. Center of Gravity. 054 058 064 068 AB AB 1 2 3 4 48EJD/EKD 6805 (3087) 7055 (3200) 7305 (3314) 7480 (3393) 3. Do not locate adjacent units with flue discharge facing econo- 48EJD/EKD054 130.9 46.9 3325 1192 22.4 19.6 27.0 30.9 mizer inlet. 48EJE 7045 (3196) 7295 (3309) 7545 (3422) 7720 (3502) 48EJE054 133.8 47.4 3397 1204 2

Summary of the content on the page No. 16

16 NOTES: 1. Weights include economizer (standard). 2. Center of Gravity. 3. Do not locate adjacent units with flue discharge facing econo- mizer inlet. Min Clearances to be: Adjacent Units: 15 ′-0 ″ [4572]. Top of Units: No Overhang. Condenser Coil: 4 ′-0 ″ [1219]. Economizer Side: 6 ′-0 ″ [1829]. Heat Side: 4 ′-0 ″ [1219]. Filter Access Side: 15 ′-0 ″ [4572]. (For removal of evaporator coil.) 4. For smaller service and operational clearances contact Carrier Application Engineering Department.

Summary of the content on the page No. 17

17 NOTES: 1. Weights include economizer (standard). 2. Center of Gravity. 3. Do not locate adjacent units with flue discharge facing econo- mizer inlet. Min Clearances to be: Adjacent Units: 15 ′-0 ″ [4572]. Top of Units: No Overhang. Condenser Coil: 4 ′-0 ″ [1219]. Economizer Side: 6 ′-0 ″ [1829]. Heat Side: 4 ′-0 ″ [1219]. Filter Access Side: 15 ′-0 ″ [4572]. (For removal of evaporator coil.) 4. For smaller service and operational clearances contact Carrier Application Engineering Department.

Summary of the content on the page No. 18

18 NOTES: BASE UNIT WEIGHTS CENTER OF GRAVITY 1. Weights include economizer (standard). % OF TOTAL WEIGHT (See Note 6) lbs (kg) AT EACH CORNER UNIT SIZE Inches Millimeters 2. Center of Gravity. 054 058 064 068 AB AB 1 2 3 4 48EWD/EYD 6845 (3105) 7095 (3218) 7345 (3332) 7520 (3411) 3. Do not locate adjacent units with flue discharge 48EWD/EYD054 130.9 46.9 3325 1192 22.4 19.6 27.0 30.9 facing economizer inlet. 48EWE 7085 (3214) 7335 (3327) 7585 (3441) 7760 (3520) 48EWE054 133.8 47.4 3397 1204 23.

Summary of the content on the page No. 19

A 2 3 B 4 1 48AJ,AK,AW,AY UNITS CENTER OF GRAVITY PERCENT OF TOTAL WEIGHT AT EACH CORNER (%) UNIT Inches Millimeters AB A B 1 2 3 4 48AJ,AKD020 72.4 42.2 1839 1072 21.0% 22.8% 29.2% 26.9% 48AJE020 73.3 42.7 1862 1085 21.6% 22.9% 28.6% 27.0% 48AW,AYD020 72.4 42.2 1839 1072 21.0% 22.8% 29.2% 26.9% 48AWE020 73.3 42.7 1862 1085 21.6% 22.9% 28.6% 27.0% 48AJ,AKD025 69.6 44.0 1768 1118 21.1% 21.1% 28.9% 28.9% 48AJE025 70.1 44.3 1781 1125 21.4% 21.1% 28.6% 29.0% 48AW,AYD025 69.6 44.0 1768 1118 21.1% 21.

Summary of the content on the page No. 20

48EJ,EK,EW,EY UNITS CENTER OF GRAVITY PERCENT OF TOTAL WEIGHT AT EACH CORNER (%) UNIT Inches Millimeters AB A B 1 2 3 4 48EJ,EW,EK,EYD024 72.4 42.2 1839 1072 21.0 22.8 29.2 26.9 48EJ,EWE024 73.3 42.7 1862 1085 21.6 22.9 28.6 27.0 48EJ,EW,EK,EYD028 69.6 44.0 1768 1118 21.1 21.1 28.9 28.9 48EJ,EWE028 70.1 44.3 1781 1125 21.4 21.1 28.6 29.0 48EJ,EW,EK,EYD030 69.6 44.0 1768 1118 21.1 21.1 28.9 28.9 48EJ,EWE030 70.1 44.3 1781 1125 21.4 21.1 28.6 29.0 48EJ,EW,EK,EYD034 69.6 44.0 1768 1118 21.1 21.1 28


Alternative user manuals
# User manual Category Download
1 Carrier 024 User manual Air Conditioner 588
2 Carrier 09DK054-094 User manual Air Conditioner 100
3 Carrier 09DK054-084 User manual Air Conditioner 48
4 Carrier 17DA User manual Air Conditioner 26
5 Carrier 09DC User manual Air Conditioner 32
6 Carrier 040-420 User manual Air Conditioner 66
7 Carrier 17EX User manual Air Conditioner 14
8 Carrier 19 User manual Air Conditioner 17
9 Carrier 1995 User manual Air Conditioner 31
10 Carrier 09BB User manual Air Conditioner 11
11 Carrier 19DG User manual Air Conditioner 17
12 Carrier 19XRV User manual Air Conditioner 90
13 Carrier 30GA User manual Air Conditioner 32
14 Carrier 30GB User manual Air Conditioner 178
15 Carrier 30GX080-176 User manual Air Conditioner 22
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21