Carrier 40RMS008-034 user manual

User manual for the device Carrier 40RMS008-034

Device: Carrier 40RMS008-034
Category: Air Conditioner
Manufacturer: Carrier
Size: 1.06 MB
Added : 12/5/2013
Number of pages: 48
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier 40RMS008-034. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier 40RMS008-034.

For your convenience

If looking through the Carrier 40RMS008-034 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier 40RMS008-034 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier 40RMS008-034 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier 40RMS008-034 User manual - Online PDF
Advertisement
« Page 1 of 48 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier 40RMS008-034 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier 40RMS008-034. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

40RM007-034
40RMQ008-028
40RMS008-034
Packaged Air-Handling Units
50/60 Hz
Installation, Start-Up and
Service Instructions
CONTENTS Recognize safety information. This is the safety-alert sym-
bol ( ). When you see this symbol on the unit and in instruc-
Page
tions or manuals, be alert to the potential for personal injury.
SAFETY CONSIDERATIONS...................... 1
Understand the signal words — DANGER, WARNING,
PRE-INSTALLATION.............................1,2
and CAUTION. These words are used

Summary of the content on the page No. 2

support unit weight (Tables 1A-1F). See Fig. 1A-1C for Moving and Storage — To transfer unit from truck to dimensions. storage site, use a fork truck. Do not stack units more than 2 high during storage. If unit is to be stored for more than Uncrating — Move unit as near as possible to final loca- 2 weeks before installation, choose a level, dry storage site free tion before removing shipping skid. from vibration. Do not remove plastic wrap or skid from unit Remove metal banding, top skid, and pl

Summary of the content on the page No. 3

Table 1A — 40RM Physical Data, English — Cooling Units UNIT 40RM 007 008 012 014 016 024 028 034 1 1 NOMINAL CAPACITY (Tons) 67 / 10 12 / 15 20 25 30 2 2 OPERATING WEIGHT (lb) Base Unit with TXV 381 385 405 670 685 690 1020 1030 Plenum 175 175 175 225 225 225 325 325 FANS Qty...Diam. (in.) 1...15 1...15 1...15 2...15 2...15 2...15 2...18 2...18 Nominal Airflow (cfm) 2400 3000 4000 5000 6000 8,000 10,000 12,000 1800- 2250- 3000- 3750- 4500- 6,000- 7,500- 9,000- Airflow Range (cfm) 3000 3750 5000

Summary of the content on the page No. 4

Table 1B — 40RMQ Physical Data, English — Heat Pump Units UNIT 40RMQ 008 012 016 024 028 1 NOMINAL CAPACITY (Tons) 7 / 10 15 20 25 2 OPERATING WEIGHT (lb) Base Unit with TXV 385 427 713 720 1050 Plenum 175 175 225 140 180 FANS Qty...Diam. (in.) 1...15 1...15 2...15 2...15 2...18 Nominal Airflow (cfm) 3000 4000 6000 8000 10,000 Airflow Range (cfm) 2250-3750 3000-5000 4500-7500 6000-10,000 7500-12,500 Nominal Motor Hp (Standard Motor) 208/230-1-60 2.4 ———— 208/230-3-60 and 460-3-60 2.4 2.4 3.7 5.0

Summary of the content on the page No. 5

Table 1C — 40RMS Physical Data, English — Chilled Water Units UNIT 40RMS 008 010 012 014 016 024 028 034 1 1 1 NOMINAL CAPACITY (Tons) 7 / 8 / 10 12 / 15 20 25 30 2 2 2 OPERATING WEIGHT (lb) Base Unit 390 391 391 661 677 683 1035 1042 Plenum 175 175 175 225 225 225 325 325 FANS Qty...Diam. (in.) 1...15 1...15 1...15 2...15 2...15 2...15 2...18 2...18 Nominal Airflow (cfm) 3000 3400 4000 5000 6000 8000 10,000 12,000 Airflow Range (cfm) 2250-3750 2250-4250 3000-5000 3750-6250 4500-7500 6000-10,000

Summary of the content on the page No. 6

Table 1D — 40RM Physical Data, SI — Cooling Units UNIT 40RM 007 008 012 014 016 024 028 034 NOMINAL CAPACITY (kW) 21 26 35 43 52 70 87 105 OPERATING WEIGHT (kg) Base Unit with TXV 173 175 184 304 311 313 463 467 Plenum 80 80 80 102 102 102 148 148 FANS Qty...Diam. (mm) 1...381 1...381 1...381 2...381 2...381 2...381 2...457 2...457 Nominal Airflow (L/s) 1133 1604 1888 2360 2831 3775 4719 5663 Airflow Range (L/s) 850-1416 1203-2006 1416-2360 1770-2949 2124-3539 2831-4719 3539-5899 4247-7079 Nomin

Summary of the content on the page No. 7

Table 1E — 40RMQ Physical Data, SI — Heat Pump Units UNIT 40RMQ 008 012 016 024 028 NOMINAL CAPACITY (kW) 26 35 52 70 87 OPERATING WEIGHT (kg) Base Unit with TXV 175 194 323 326 477 Plenum 80 80 102 44 44 FANS Qty...Diam. (mm) 1...381 1...381 2...381 2...381 2...457 Nominal Airflow (L/s) 1604 1888 2831 3775 4719 Airflow Range (L/s) 1203-2006 1416-2360 2124-3539 2831-4719 3539-5899 Nominal Motor kW (Standard Motor) 208/230-1-60 1.79 — — — — 208/230-3-60 and 460-3-60 1.79 1.79 2.76 3.73 5.60 575-3

Summary of the content on the page No. 8

Table 1F — 40RMS Physical Data, SI — Chilled Water Units UNIT 40RMS 008 010 012 014 016 024 028 034 NOMINAL CAPACITY (kW) 26 29 35 43 52 70 87 105 OPERATING WEIGHT (kg) Base Unit 177 177 177 300 307 310 469 473 Plenum 80 80 80 102 102 102 148 148 FANS Qty...Diam. (mm) 1...381 1...381 1...381 2...381 2...381 2...381 2...457 2...457 Nominal Airflow (L/s) 1416 1605 1888 2360 2831 3775 4719 5663 Airflow Range (L/s) 1062-1770 1204-2006 1416-2360 1770-2949 2124-3539 2831-4719 3539-5899 4247-7079 Nomin

Summary of the content on the page No. 9

LEGEND TXV — Thermostatic Expansion Valve NOTES: 1. Dimensions in [ ] are in millimeters. 2. Direction of airflow. 3. Recommended clearance:  Rear: 3 in. (76 mm)  Front: 2 ft, 6 in. (762 mm)  Right Side: 2 ft, 6 in. (762 mm)  Left Side: 2 ft, 6 in. (762 mm)  Local codes or jurisdiction may prevail. 4. Liquid piping not supplied by Carrier. 5. Duct flange is factory supplied and field installed. 6. 40RMS units may require alternate or addi- tional field-fabricated

Summary of the content on the page No. 10

LEGEND TXV — Thermostatic Expansion Valve NOTES: 1. Dimensions in [ ] are in millimeters. 2. Direction of airflow. 3. Recommended clearance:  Rear: 3 in. (76 mm)  Front: 2 ft, 6 in. (762 mm)  Right Side: 2 ft, 6 in. (762 mm)  Left Side: 2 ft, 6 in. (762 mm)  Local codes or jurisdiction may prevail. 4. Liquid piping not supplied by Carrier. 5. Duct flange is factory-supplied and field-installed. 6. 40RMQ016,024 and 40RMS units may require alternate or additional fi

Summary of the content on the page No. 11

LEGEND TXV — Thermostatic Expansion Valve NOTES: 1. Dimensions in [ ] are in millimeters. 2. Direction of airflow. 3. Recommended clearance:  Rear: 3 in. (76 mm)  Front: 2 ft, 6 in. (762 mm)  Right Side: 2 ft, 6 in. (762 mm)  Left Side: 2 ft, 6 in. (762 mm)  Local codes or jurisdiction may prevail. 4. Liquid piping not supplied by Carrier. 5.Duct flange is factory-supplied and field-installed. 6. 40RMQ028 and 40RMS may require alternate or additional field fabrica

Summary of the content on the page No. 12

40RM–016 ––B501GC Factory-Installed Options 40RM – Commercial Packaged GC – Unpainted, Standard Motor, Air Handler and Standard Drive HC – Unpainted, Standard Motor, Cooling Coil and Medium-Static Drive –– Direct Expansion (Not available for 60 Hz 028 size Q– Direct Expansion for Heat Pump Duty or 50 Hz 016-028 sizes) S– Chilled Water TC – Unpainted, Alternate Motor, and Medium-Static Drive (60 Hz 028 size and Nominal Capacity – Tons (kW) 50 Hz 016-028 sizes) 007 – 6 (21) 016 – 15 (52) YC – Unpa

Summary of the content on the page No. 13

Unit Positioning — The unit can be mounted on the floor for vertical application with return air entering the face of the unit and supply air discharging vertically through the top of the unit. The unit can also be applied in a horizontal arrange- ment with return air entering horizontally and the supply air discharging horizontally. When applying the unit in a horizon- tal arrangement, ensure the condensate drain pan is located at the bottom center of the unit for adequate condensate disposal.

Summary of the content on the page No. 14

OVERHEAD SUSPENSION ACCESSORY UNIT SIZES 007-012 UNIT SIZES 014-024 UNIT SIZES 028,034 NOTE: Dimensions in [ ] are millimeters. Fig. 5 — Preferred Suspension Technique 14

Summary of the content on the page No. 15

FIELD-FABRICATED HOLE DIAMETERS, FIELD-FABRICATED HOLE POSITION USE HOLE in. (mm) DIMENSIONS, in. (mm) UNIT NUMBERS No.5No.6No.7No.8 ABCD 40RM007,008 1, 3 — — — — — — — — 40RMQ008 40RM012-034 1, 2, 3, 4 — — — — — — — — 40RMQ012 3 40RMS008-012 4, 5 1 / (44.5) — — — 6.25 (158.8) — — — 4 3 3 3 40RMS014-024 4, 5, 6, 7 1 / (44.5) 1 / (44.5) 1 / (44.5) — 3.0 (76.2) 6.0 (152.4) 10.5 (266.7) — 4 4 4 1 1 3 40RMQ016,024,028 3*, 5, 6, 7 1 / (28.6) 1 / (28.6) 1 / (44.5) — 3.25 (82.6) 6.125 (155.6) 10.38 (26

Summary of the content on the page No. 16

UNIT QUANTITY REQUIRED FIGURE REFERENCE 38ARQ008,012 1B LEGEND 38AQS016 2A TXV — Thermostatic Expansion Valve 38ARQ012 (2) 2A NOTE: The 8 o’clock position is shown above. 38ARQ012, 2A AQS016 Fig. 9 — TXV Sensing Bulb Location LEGEND TXV — Thermostatic Expansion Valve Fig. 11 — Filter Drier Quantity and Location DISCONNECT PER NEC ELECTRIC HEATER ACCESSORY 24 V CONTROL WIRE FUSED DISCONNECT SWITCH* CONDENSING BULB CAPILLARY UNIT B 40RMQ024 TUBES UNIT RETURN 8 DIAMS AIR MIN SIGHT GLASS* FILTER SUB

Summary of the content on the page No. 17

Table 2 — Factory-Installed Nozzle and Distributor Data FEEDER TUBES COIL TXV DISTRIBUTOR NOZZLE UNIT PER DISTRIBUTOR* TYPE Qty...Part No. Qty...Part No. Qty...Part No. Qty...Size (in.) 1 40RM007 3, 4 Row 1...TDEBX8 1...1116 12... / 1...E5 4 1 / 1...C6 40RM008 3, 4 Row 1...TDEBX8 1...1126 15... 4 1 40RMQ008 — 1...TDEBX8 1...1657 15... / 1...C6 4 1 40RM012 3, 4 Row 2...TDEX6 2...1115 9... / 2...E4 4 1 40RMQ012 — 2...TDEX4 2...1655 9... / 2...E4 4 1 3 Row 2...TDEBX8 9... / 4 40RM014 2...1115 2...E

Summary of the content on the page No. 18

Table 3 — Fitting Requirements (cont) ACCESS CONNECTION FITTINGS REQUIRED† UNIT CIRCUIT HOLE NO.* TYPE (in.) 1 1 / Street Elbow 8 1 5 1 Suction Lower 1 / Nipple, 7 / L 8 8 1 1 / Long Radius Elbow 8 5 / Street Elbow 8 5 7 / Nipple, 1 / L 2 Liquid Lower 8 16 5 / Long Radius Elbow 8 40RM 5 / Street Elbow 8 014 5 1 3 Liquid Upper / Nipple, 11 / L 8 2 5 / Long Radius Elbow 8 1 5 1 / Nipple, 5 / L 8 8 1 1 / Long Radius Elbow 8 4 Suction Upper 1 1 / Nipple, 13 L 8 1 1 / Long Radius Elbow 8 3 1 / Long R

Summary of the content on the page No. 19

Table 3 — Fitting Requirements (cont) ACCESS CONNECTION FITTINGS REQUIRED† UNIT CIRCUIT HOLE NO.* TYPE (in.) 1 2 / Long Radius Elbow 8 1 1 5 Supply Lower 2 / Nipple, 3 / L 8 2 1 2 / Long Radius Elbow 8 1 2 / Long Radius Elbow 8 1 2 / Nipple, 3 L 6 Return Lower 8 1 2 / Long Radius Elbow 40RMS 8 028, 034 1 2 / Long Radius Elbow 8 1 7 7 Return Upper 2 / Nipple, 6 / L 8 8 1 2 / Long Radius Elbow 8 1 2 / Long Radius Elbow 8 1 7 2 / Nipple, 11 / L 8 Supply Upper 8 8 1 2 / Long Radius Elbow 8 3 1 / Str

Summary of the content on the page No. 20

See Fig. 14. Loosen the 2 screws next to the drain outlet at both Condensate Drain — Install a trapped condensate drain ends of the unit, push drain pan down in the slots near the drain line to unit connection as shown in Fig. 13. The unit drain con- connection, and up in the slots on the opposite end. Retighten nection is a PVC stub. See Fig. 14. Some areas may require an 1 screws. The pan should have a pitch of at least / -in. over its adapter to connect to either galvanized steel or copper pi


Alternative user manuals
# User manual Category Download
1 Carrier 024 User manual Air Conditioner 588
2 Carrier 09DK054-094 User manual Air Conditioner 100
3 Carrier 09DK054-084 User manual Air Conditioner 48
4 Carrier 17DA User manual Air Conditioner 26
5 Carrier 09DC User manual Air Conditioner 32
6 Carrier 040-420 User manual Air Conditioner 66
7 Carrier 17EX User manual Air Conditioner 14
8 Carrier 19 User manual Air Conditioner 17
9 Carrier 1995 User manual Air Conditioner 31
10 Carrier 09BB User manual Air Conditioner 11
11 Carrier 19DG User manual Air Conditioner 17
12 Carrier 19XRV User manual Air Conditioner 90
13 Carrier 30GA User manual Air Conditioner 32
14 Carrier 30GB User manual Air Conditioner 178
15 Carrier 30GX080-176 User manual Air Conditioner 22
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21