40KMC------301
40KMQ------301
OWNER’S MANUAL
Summary of the content on the page No. 2
40KMC------310/ 40KMQ------310 Split system “Global cassette” indoor unit IR Remote Control “Room Controller” “Zone Manager” The unit can be used with infrared Remote Control, with the Carrier “Room Controller” or “Zone Manager” remote control. Carrier “Room controller” control instructions are contained in the present manual. Infrared Remote and “Zone Manager” controls instructions are contained in the relevant manuals. The installation instructions for both the indoor and the outdoor unit ar
Summary of the content on the page No. 3
40KMC------310/ 40KMQ------310 General information smell of burning) and call Carrier Service for further instructions. Unit operation and maintenance • A routine maintenance should be carried out on the unit to check the Read this instruction manual thoroughly before using the unit. correct operation of the electric connections and protection devices. • Extraordinary maintenance operations must be carried out by • This unit complies with UL 1995 directive (Usa and Canada). specially trained per
Summary of the content on the page No. 4
40KMC------310/ 40KMQ------310 Unit warning lights and controls - Fault code ENGLISH P : Green LED Q : Red LED R : Yellow LED S : Remote control signal receiver Indoor unit LEDs Fault code Once a failure occurs with the indoor unit in operation, the green Information concerning indoor unit operation, timer status and unit LED flashes at intervals of 0.5 seconds. diagnostic is given by 3 LEDs located on the unit. The fault code is deduced from the number of times the green • THE GREEN LED (P) sho
Summary of the content on the page No. 5
40KMC------310/ 40KMQ------310 Optimum comfort... - Correct cleaning - Before a long shutdown period Optimum comfort and minimum power Correct cleaning consumption • Turn the unit OFF and switch the main supply OFF. Keep room temperature at a comfortable level. Use only a clean, damp cloth and a mild detergent. Do not use flammable liquids, solvents or abrasive powders that may result in damage to the panels. Use only a dry cloth to clean the remote control. Before a long shutdown period Only op
Summary of the content on the page No. 6
40KMC------310/ 40KMQ------310 “Room controller” general information and characteristics ENGLISH Characteristics • Single unit operation: Ability to control one unit only. • Grouping: Ability to control 2 to 6 units with one Room Controller. • Operating modes: Off, Heat, Cool, Dry, Auto, and Fan only. A B A = Display readout • Fan speeds: B = Increase Low, Medium, High, and Auto. temperature / change louvre • Louver control: setting button Auto and swing. C = Decrease temperature / • Desired tem
Summary of the content on the page No. 7
40KMC------310/ 40KMQ------310 “Room controller” wired control Power up AUTO, HEAT, COOL and DRY Modes: All segments of the LCD should be energized for five seconds. ICONS Energized: The mode, fan, louver, desired temperature and configuration • Operation Mode ICON. information should be read from the EEPROM. • Room Temperature if configured for Room Thermistor Override If the EEPROM values are not valid, the following should be used (operated by Room Controller), otherwise user selected as def
Summary of the content on the page No. 8
40KMC------310/ 40KMQ------310 “Room controller” wired control ENGLISH Auto mode setting will be displayed by blinking the fan Medium FAN ONLY Mode: speed and High speed icons in order (Med then Hi then repeat). ICONS Energized: • Room Temperature if configured for Room Thermistor Override Low (operated by Room Controller), otherwise nothing. • FAN/LOUVER Icon with the user selected Fan and Louver Medium settings. Buttons available: High •“MODE” and “FAN” buttons are available. Automatic (Fan sp
Summary of the content on the page No. 9
40KMC------310/ 40KMQ------310 Troubleshooting No Room controller LCD display: service, please refer to the installation instructions. • Mis-wiring of the 12 volt power to Room Controller control; Restart air conditioner after having corrected the faults. verify that + 12 V and Ground are connected to the proper terrminals of the Controller (Reference Installation wiring section for correct connections): after disconnecting the Q (Red LED) indicator is illuminated: power, correct the wiring prob
Summary of the content on the page No. 10