Bryant Single Package Gas Heating /Electric Cooling Units 588A user manual

User manual for the device Bryant Single Package Gas Heating /Electric Cooling Units 588A

Device: Bryant Single Package Gas Heating /Electric Cooling Units 588A
Category: Air Conditioner
Manufacturer: Bryant
Size: 1.89 MB
Added : 4/14/2013
Number of pages: 52
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant Single Package Gas Heating /Electric Cooling Units 588A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant Single Package Gas Heating /Electric Cooling Units 588A.

For your convenience

If looking through the Bryant Single Package Gas Heating /Electric Cooling Units 588A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant Single Package Gas Heating /Electric Cooling Units 588A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant Single Package Gas Heating /Electric Cooling Units 588A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant Single Package Gas Heating /Electric Cooling Units 588A User manual - Online PDF
Advertisement
« Page 1 of 52 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant Single Package Gas Heating /Electric Cooling Units 588A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant Single Package Gas Heating /Electric Cooling Units 588A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

588A
installation, start-up
Sizes 018-060
and service instructions
589A
Sizes 024-060
SINGLE PACKAGE GAS HEATING/
ELECTRIC COOLING UNITS
Cancels: II 588A-18-8 II 588A-18-9
9/15/98
CONTENTS
Page
SAFETY CONSIDERATIONS........................1
General.........................................1
RECEIVING AND INSTALLATION .................10-22
I. Step 1 — Check Equipment .................10
II. Step 2 — Provide Unit Support ..............10
III. Step 3 — Field Fabricate Ductwork ...........10
IV. Ste

Summary of the content on the page No. 2

REQ’D CLEARANCES FOR SERVICING. in. (mm) Duct panel.............................0 Unit top...........................36 (914) Side opposite ducts .....................36 (914) Compressor access .....................36 (914) (Except for NEC requirements) REQ’D CLEARANCES TO COMBUSTIBLE MAT’L. in. (mm) Maximum extension of overhangs...............48 (1219) Unit top...........................14 (356) Duct side of unit ........................2 (51) Side opposite ducts .....................14 (356)

Summary of the content on the page No. 3

REQ’D CLEARANCES FOR SERVICING. in. (mm) Duct panel.............................0 Unit top...........................36 (914) Side opposite ducts .....................36 (914) Compressor access .....................36 (914) (Except for NEC requirements) REQ’D CLEARANCES TO COMBUSTIBLE MAT’L. in. (mm) Maximum extension of overhangs...............48 (1219) Unit top...........................14 (356) Duct side of unit ........................2 (51) Side opposite ducts .....................14 (356)

Summary of the content on the page No. 4

REQ’D CLEARANCES FOR SERVICING. in. (mm) Duct panel.............................0 Unit top...........................36 (914) Side opposite ducts .....................36 (914) Compressor access .....................36 (914) (Except for NEC requirements) REQ’D CLEARANCES TO COMBUSTIBLE MAT’L. in. (mm) Maximum extension of overhangs...............48 (1219) Unit top...........................14 (356) Duct side of unit ........................2 (51) Side opposite ducts .....................14 (356)

Summary of the content on the page No. 5

REQ’D CLEARANCES FOR SERVICING. in. (mm) Duct panel.............................0 Unit top...........................36 (914) Side opposite ducts .....................36 (914) Compressor access .....................36 (914) (Except for NEC requirements) REQ’D CLEARANCES TO COMBUSTIBLE MAT’L. in. (mm) Maximum extension of overhangs...............48 (1219) Unit top...........................14 (356) Duct side of unit ........................2 (51) Side opposite ducts .....................14 (356)

Summary of the content on the page No. 6

REQ’D CLEARANCES FOR SERVICING. in. (mm) Duct panel.............................0 Unit top...........................36 (914) Side opposite ducts .....................36 (914) Compressor access .....................36 (914) (Except for NEC requirements) REQ’D CLEARANCES TO COMBUSTIBLE MAT’L. in. (mm) Maximum extension of overhangs...............48 (1219) Unit top...........................14 (356) Duct side of unit ........................2 (51) Side opposite ducts .....................14 (356)

Summary of the content on the page No. 7

REQ’D CLEARANCES FOR SERVICING. in. (mm) Duct panel...........................0 Unit top .........................36 (914) Side opposite ducts....................36 (914) Compressor access....................36 (914) (Except for NEC requirements) REQ’D CLEARANCES TO COMBUSTIBLE MAT’L. in. (mm) Maximum extension of overhangs.............48 (1219) Unit top .........................14 (356) Duct side of unit ......................2 (51) Side opposite ducts....................14 (356) Bottom of unit

Summary of the content on the page No. 8

REQ’D CLEARANCES FOR SERVICING. in. (mm) Duct panel.............................0 Unit top...........................36 (914) Side opposite ducts .....................36 (914) Compressor access .....................36 (914) (Except for NEC requirements) REQ’D CLEARANCES TO COMBUSTIBLE MAT’L. in. (mm) Maximum extension of overhangs...............48 (1219) Unit top...........................14 (356) Duct side of unit ........................2 (51) Side opposite ducts .....................14 (356)

Summary of the content on the page No. 9

REQ’D CLEARANCES FOR SERVICING. in. (mm) Duct panel.............................0 Unit top...........................36 (914) Side opposite ducts .....................36 (914) Compressor access .....................36 (914) (Except for NEC requirements) REQ’D CLEARANCES TO COMBUSTIBLE MAT’L. in. (mm) Maximum extension of overhangs...............48 (1219) Unit top...........................14 (356) Duct side of unit ........................2 (51) Side opposite ducts .....................14 (356)

Summary of the content on the page No. 10

RECEIVING AND INSTALLATION Ducts passing through an unconditioned space must be in- sulated and covered with a vapor barrier. I. STEP 1 — CHECK EQUIPMENT Ifaplenumreturnisusedonaverticalunit,thereturnshould A. Identify Unit be ducted through the roof deck to comply with applicable fire codes. The unit model number and serial number are stamped on unitidentificationplate.Checkthisinformationagainstship- Aminimumclearanceisnotrequiredaroundductwork.Cabi- ping papers and job data. net return-air stat

Summary of the content on the page No. 11

PART NUMBER ‘‘A’’ CPRFCURB001A00 89 [203] FLAT CPRFCURB002A00 119 [279] CURB CPRFCURB003A00 149 [356] NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied as required for unit being installed. 3. Dimensions in [ ] are in millimeters. 4. Roof curb is made of 16 gage steel. 5. Attach ductwork to curb (flanges of duct rest on curb). 6. Service clearance 4 ft on each side. 7. Direction of airflow. 8. Insulated panels: 1-in. thick fiberglass 1 lb density. Fig. 10 —

Summary of the content on the page No. 12

NOTICE TO RIGGERS Hookriggingshacklesthroughholesinliftingbrackets,asshowninDe- tail‘‘A.’’Liftingbracketstobecenteredaroundtheunitcenterofgravity. Use wood top skid when rigging, to prevent rigging straps from damag- ing unit. Remove 4 screws to slide wood support through rectangular hole in rail. CAUTION: All panels must be in place when rigging. UNIT MAX AB C 588A WEIGHT Fig. 11 — Slab Mounting Details Size lb kg in. mm in. mm in. mm 018 320 145 24.4 619 28.2 715 024 363 165 22.6 574 28.2 715

Summary of the content on the page No. 13

B. Units With Optional Base Rail 2. Remove from shipping location. Place vent cap assem- blyoverfluepanel.Orientscrewholesinventcapwith Lifting holes are provided in optional base rail as shown in holes in the flue panel. Fig. 13. Operating weights are shown in Tables 1 and 2. Re- fer to rigging instructions on unit. 3. Securefluehoodtofluepanelbyinsertingasinglescrew on the right side, the left side, and the top of the hood. Protective wood support must be removed from unit before unit is mounted t

Summary of the content on the page No. 14

Table 1 — Physical Data — Unit 588A UNIT SIZE 588A 018040 024040 024060 030040 030060 030080 036060 036080 036100 036120 1 1 1 1 NOMINAL CAPACITY (ton) 1 ⁄2 22 2⁄2 2⁄2 2⁄2 3333 OPERATING WEIGHT (lb) Without Base Rail 272 303 315 320 332 332 336 336 348 348 With Optional Base Rail 296 327 339 344 356 356 360 360 372 372 COMPRESSORS Rotary Reciprocating Quantity 11 REFRIGERANT (R-22) Charge (lb) 2.60 2.75 2.75 3.40 3.40 3.40 4.30 4.30 4.30 4.30 REFRIGERANT METERING DEVICE Acutrol™ Device Orifice ID

Summary of the content on the page No. 15

Table 2 — Physical Data — Unit 589A UNIT SIZE 589A 024040 024060 030040 030060 030080 036060 036080 036100 036120 1 1 1 NOMINAL CAPACITY (ton) 22 2⁄2 2⁄2 2⁄2 3333 OPERATING WEIGHT (lb) Without Base Rail 333 345 336 348 348 366 366 378 378 With Optional Base Rail 357 369 360 372 372 390 390 402 402 COMPRESSORS Scroll Quantity 1 REFRIGERANT (R-22) Charge (lb) 3.9 3.9 4.5 4.5 4.5 5.4 5.4 5.4 5.4 REFRIGERANT METERING DEVICE Acutrol™ Device Orifice ID (in.) .034 .034 .030 .030 .030 .032 .032 .032 .032

Summary of the content on the page No. 16

(Text continued from page 13) A. Configuring Units for Downflow (Vertical) Discharge CAUTION: Unstable operation may occur when the WARNING:Before performing service or mainte- gas valve and manifold assembly are forced out of po- nanceoperationsonthesystem,turnoffmainpowerto sitionwhileconnectingimproperly-routedrigidgaspip- unit or electrical shock could result. ing to the gas valve. Use a backup wrench when mak- ing connection to avoid strain on, or distortion of, the gas control piping. 1. Ope

Summary of the content on the page No. 17

Table 3 — Maximum Gas Flow Capacity* NOMINAL LENGTH OF PIPE, FT† INTERNAL IRON PIPE, DIAMETER SIZE (in.) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 (in.) 1 ⁄2 .622 175 120 97 82 73 66 61 57 53 50 44 40 — — 3 ⁄4 .824 360 250 200 170 151 138 125 118 110 103 93 84 77 72 1 1.049 680 465 375 320 285 260 240 220 205 195 175 160 145 135 1 1 ⁄4 1.380 1400 950 770 600 580 530 490 460 430 400 360 325 300 280 1 1 ⁄2 1.610 2100 1460 1180 990 900 810 750 690 650 620 550 500 460 430 *Capacity of pipe in c

Summary of the content on the page No. 18

X. STEP 10 — INSTALL ELECTRICAL CONNECTIONS WARNING:The unit cabinet must have an uninter- rupted,unbrokenelectricalgroundtominimizethepos- sibility of personal injury if an electrical fault should occur.Thisgroundmayconsistofanelectricalwirecon- nected to the unit ground lug in the control compart- ment, or conduit approved for electrical ground when installed in accordance with NEC (National Electrical Code) ANSI/NFPA (latest edition) (in Canada, Cana- dian Electrical Code CSA [Canadian Standa

Summary of the content on the page No. 19

Table 4A — Electrical Data — Unit 588A VOLTAGE OUTDOOR-FAN INDOOR-FAN UNIT AWG60C COMPRESSOR POWER SUPPLY MAX WIRE RANGE MOTOR MOTOR SIZE V-PH-Hz MIN WIRE LENGTH (ft) 588A SIZE Min Max RLA LRA FLA FLA MCA MOCP* 018 208/230-1-60 187 253 8.3 45.0 0.7 1.8 12.9 15 14 75 024 208/230-1-60 187 253 12.4 61.0 0.7 2.0 18.2 30 12 80 208/230-1-60 187 253 14.4 82.0 1.4 2.3 21.4 30 10 100 030 208/230-3-60 187 253 9.4 66.0 1.4 2.0 15.1 25 12 80 208/230-1-60 187 253 18.0 96.0 1.4 2.8 26.7 40 10 90 036 208/230-3

Summary of the content on the page No. 20

Table 4B — Electrical Data — Unit 589A VOLTAGE OUTDOOR-FAN INDOOR-FAN UNIT AWG60C COMPRESSOR POWER SUPPLY MAX WIRE RANGE MOTOR MOTOR SIZE V-PH-Hz MIN WIRE LENGTH (ft) 589A SIZE Min Max RLA LRA FLA FLA MCA MOCP* 024 208/230-1-60 187 253 12.9 62.5 1.4 2.0 19.5 30 12 75 030 208/230-1-60 187 253 15.0 76.0 1.4 2.6 22.8 30 10 100 208/230-1-60 187 253 16.7 95.0 1.4 2.8 25.1 30 10 95 036 208/230-3-60 187 253 10.9 75.0 1.4 2.8 17.8 25 12 70 460-3-60 414 506 5.4 40.0 0.8 1.4 9.0 10 14 100 208/230-1-60 187


Alternative user manuals
# User manual Category Download
1 Bryant 113A User manual Air Conditioner 365
2 Bryant 24B User manual Air Conditioner 61
3 Bryant 187B User manual Air Conditioner 39
4 Bryant 342S User manual Air Conditioner 17
5 Bryant 39479D8 User manual Air Conditioner 31
6 Bryant 342 User manual Air Conditioner 15
7 Bryant 165A User manual Air Conditioner 22
8 Bryant 450D User manual Air Conditioner 21
9 Bryant 451P User manual Air Conditioner 7
10 Bryant 451 User manual Air Conditioner 7
11 Bryant 36-453 User manual Air Conditioner 10
12 Bryant 452W User manual Air Conditioner 6
13 Bryant 452 User manual Air Conditioner 3
14 Bryant 454 User manual Air Conditioner 112
15 Bryant 463AAC008BA User manual Air Conditioner 17
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21