Summary of the content on the page No. 1
Installation Instructions / Warranty
Axor Montreux
16532XX1
Axor Montreux
16534XX1
Summary of the content on the page No. 2
Axor Montreux Wall-Mounted Widespread Lavatory Set 16532XX1 Cross handles 16534XX1 Lever handles 16532XX1 16534XX1 Technical Information Recommended water pressure 14.7 - 72.5 psi Max. water pressure 147 psi Recommended hot water temp. 120� - 140� F* Max. hot water temp 176�F* Flow rate 2.2 gpm *Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. Installation Considerations • For best results, Hansgrohe recommends that this unit be install
Summary of the content on the page No. 3
Installation Make sure that the water is turned off at the main before beginning! Remove the caps from the plaster shields. Cut the plaster shields so that they extend 1/16" outside the wall. Seal the wall around the plaster shields with waterproof sealant. Failure to seal the wall can lead to possible water damage. Model 16534XX1 only: Remove the cartridges. Install the new cartridges included with the trim. The new hot cartridge is marked with notches on the wrench flats. 3
Summary of the content on the page No. 4
All models: Install the extension spindles (1). Cut them so that they extend 9/16" outside the surface of the wall (2). Remove the plug from the spout housing (3). Install the slip couplings (1). Cut the slip couplings so that they extend 1 5/16" outside the surface of the wall (2). Measure the distance between the front of the spout hous- ing and the surface of the wall. Record this measurement (“x”). 4
Summary of the content on the page No. 5
Add 9/16" to X. Record this measurement. Cut the threaded end of the spout so that it extends 9/16" + X from the rear of the flange. Remove the aerator (1). Wrap the threads on the spout with Teflon tape. Install the sealing ring and spout. Use a rod or dowel inserted into the end of the spout to assist in tightening it (2). Do not overtighten the spout, or damage may result. Tighten the spout flange against the wall (1). Install the aerator (2). Push the sealing ring and handle over t
Summary of the content on the page No. 6
Model 16534XX1 only: Both levers should be parallel to the floor. If one is not, remove the slip coupling (1), turn it slightly 2 (2), and reinstall it. Install the screw covers (3). 3 1 6
Summary of the content on the page No. 7
It is also possible to remove the lever, turn it slightly, and reinstall it. Install the screw covers (3). 2 1 3 User Instructions Turn the handle upward to turn the water on -- clockwise for hot, counter-clockwise for cold. Turn the handle downward to turn the water off. In the off position, the handles should be paral- lel to the floor. 7
Summary of the content on the page No. 8
Replacement Parts 2 25x2 2 1 6 4 16x2 5 3 1.1 8 9 7 1 cross handle 16291XX0 1.1 screw cover for cold/hot water 97987000 2 flange for handle 98578XX0 flange for spout 98576XX0 3 aerator cpl. 98583XX0 4 fixing set 96392000 5 extension kit, 1“ (optional) 96259000 6 spout 98574XX0 7 lever handle 16991XX0 8 hot cartridge (16534XX1 only) 96351000 9 cold cartridge (16534XX1 only) 96350000 XX = Colors 00 chrome 82 brushed nickel 83 polished nickel 8
Summary of the content on the page No. 9
Cleaning Recommendation for Hansgrohe Products Modern lavatory faucets, kitchen faucets, and showers consist of very different materials to comply with the needs of the market with regard to design and functionality. To avoid damage and returns, it is necessary to consider certain criteria when cleaning. Cleaning Materials for Faucets and Showers Acids are a necessary ingredient of cleaning materials for removing lime, however please pay attention to the following points when cleaning faucet
Summary of the content on the page No. 10
Limited Lifetime Consumer Warranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada. WHO IS COVERED BY THE WARRANTY This warranty extends to the original consumer purchaser only. This warranty is non-transferable. WHAT IS COVERED BY THE WARRANTY This warran
Summary of the content on the page No. 11
Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclu- sion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from State to State. You may be required by law to give us a reasonable opportunity to correct or cure any failure to comply before you can bring any action in court against us under the Magnuson-Moss Warranty Act. PRODUCT INSTRUCTIONS AND QUESTIONS Upon p
Summary of the content on the page No. 12
Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 Tel. 770-360-9880 • Fax 770-360-9887 www.hansgrohe-usa.com US - Installation Instructions • Part No. 90595623 • Revised 04/2008