American Standard SELECTRONIC 6065.162 user manual

User manual for the device American Standard SELECTRONIC 6065.162

Device: American Standard SELECTRONIC 6065.162
Category: Plumbing Product
Manufacturer: American Standard
Size: 0.43 MB
Added : 10/12/2013
Number of pages: 9
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for American Standard SELECTRONIC 6065.162. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with American Standard SELECTRONIC 6065.162.

For your convenience

If looking through the American Standard SELECTRONIC 6065.162 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual American Standard SELECTRONIC 6065.162 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual American Standard SELECTRONIC 6065.162 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
American Standard SELECTRONIC 6065.162 User manual - Online PDF
Advertisement
« Page 1 of 9 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual American Standard SELECTRONIC 6065.162 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to American Standard SELECTRONIC 6065.162. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SELECTRONIC™
PROXIMITY TOILET FLUSH VALVE
1.28 & 1.6 GPF
MODEL NUMBERS
6065.161 6065.162
6065.121 6065.122
6065.565 6065.525
7095.121
Exposed Flushometer
for 1-1/2" Top Spud Bowls
CL CLO OG G RE RESIST SISTA AN NT T
• Self-cleaning pist • Self-cleaning piston v on va allv ve pr e pre ev vents clogging and r ents clogging and reduces maint educes maintenance enance..
O ON NE S E SE ENSO NSOR R F FIIT TS S A AL LL L
• Onl • Only 1 sensor f y 1 sensor for entir or entire Selectr e Selectronic™ line

Summary of the content on the page No. 2

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. All American Standard Products Are Water Tested At Our Factory. UNPACKING Some Residual Water May Remain In The Valve During Shipping. 1. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be pack

Summary of the content on the page No. 3

Fig. 1 GENERAL DESCRIPTION: Roughing-in Dimensions DETECTION ZONE SELECTRONIC™ 400mm-800mm PROXIMITY TOILET (15-3/4 TO 31-1/2) FLUSH VALVE 72mm FINISHED WALL Exposed Flushometer (2-7/8) 57mm for 1-1/2" Top Spud Fixtures (2-1/4 MIN.) Exclusive, self cleaning piston-type flush valve with proximity operation and 15˚ 116mm manual override. Operates on DC (4-5/8) (battery) power. Recommended operating pressure 35 to 80 psi. Can install left or right-handed. Detection Zone can also be adjusted

Summary of the content on the page No. 4

INSTALL THE SWEAT SOLDER 1 Fig.3 ADAPTER; Fig. 3 FINISHED WALL CENTER LINE OF Turn water supplies off CAUTION FIXTURE SPUD before beginning A Note: Install Optional Sweat Solder Adapter (Supplied) for copper pipe supply line. Fig. 3. (A-B)= 1. Measure the distance (A) from the finished wall to the B 32mm C center of the inlet spud on the fixture. (1-1/4) FILE EDGES 2. Cut the supply pipe 1-1/4" (A-B=C) shorter then the measurement taken in Step 1. File any rough edges off the end of t

Summary of the content on the page No. 5

4 FLUSH OUT SUPPLY LINES; Fig. 6 Fig. 6 2 1. Remove COVER (1) from SUPPLY STOP (2). REMOVE COVER 2. With a flat blade screwdriver open SUPPLY STOP (2). 1 3. Turn on water supply to flush line of any debris or sediment. 2 4. Close SUPPLY STOP (2) and replace COVER (1). COUNTER-CLOCKWISE OPENS CONTROL STOP CLOCKWISE CLOSES CONTROL STOP Fig. 7 4 LEFT OR RIGHT HAND 5 3 INSTALLATION; Fig. 7 The UNIT is shipped with the inlet flange on the right 2 side. If needed, the orientation can be reversed

Summary of the content on the page No. 6

6 INSTALL FLUSH VALVE; Fig. 8a Fig. 8a & 8b 3 1. As shown in Fig. 8a, insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE O-RING (4) with water if necessary. Lightly tighten COUPLING NUT (5). Fig. 8a. Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape. 2. Align the FLUSH VALVE (2) (Fig. 8b) directly above the DOWN TUBE (7) and VACUUM BREAKER COUPLING NUT (6). Make sure that GASKET (10) is

Summary of the content on the page No. 7

HOW TO RETROFIT OUR VALVE; 8 Fig. 10 Fig. 10a Fig. 10b Fig. 10 6 CLEAN 2 CONNECTIONS (Replaces Industry Standard Manual and 1 Electronic Valves) Note: In most Retrofits the wall escutcheon, supply stop, 4 cover tube and vacuum breaker do not have to be replaced. If these items do need replacement they must be purchased 5 separately or order the complete flush valve assembly from American Standard. 1. Remove COVER (1) from SUPPLY STOP (2) if 3 installed. Fig. 10. 2. Turn water supply of

Summary of the content on the page No. 8

HO 10 W TO SET DETECTION RANGE Fig. 13 (If Required) ; Fig. 13 & 14 Note: The detection distance is preset and is ideal for most installations. Should an adjustment be required 6 Fig. 13a Fig. 13b follow the steps below. 3 1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in back of top half of FLUSH VALVE (3). Fig. 13a. 2. Rotate CAP (3) to the right and pull off. Fig. 13b. 1 VIEW “A” 3. Turn CAP (3) over and disconnect GREY SENSOR WIRE (4) from BATTERY COVER (5). 4. Keeping hands away

Summary of the content on the page No. 9

M968699 Rev. 1.10 8 UNIT WILL ONLY FLUSH MANUALLY UNIT DOES NOT FLUSH AT ALL IS STOP VALVE OPEN? NO OPEN VALVE LOOK FOR REPEATED DOUBLE FLASH ON SENSOR YES BATTERY LOW; YES REPLACE BATTERY NO SEE STEP 10, page 6 in manual LOOK FOR REPEATED DOUBLE FLASH ON SENSOR YES INSTALL NEW BATTERY 1. COVER SENSOR FOR 10 SECONDS 2. UNCOVER SENSOR FOR 10 SECONDS. NO RETRY AUTOMATIC FLUSH. TRY MANUAL VALVE BUTTON; DOES THE UNIT FLUSH? NO REPLACE PISTON KIT WILL THE UNIT FLUSH? NO YES TEST SENSOR. DISCONNECT


Alternative user manuals
# User manual Category Download
1 American Standard 2258 SERIES User manual Plumbing Product 1
2 American Standard 24 PO 9212024 User manual Plumbing Product 0
3 American Standard 1662 User manual Plumbing Product 2
4 American Standard 2175.21 User manual Plumbing Product 0
5 American Standard 2296 User manual Plumbing Product 0
6 American Standard 2175.2 User manual Plumbing Product 0
7 American Standard 2257.001 User manual Plumbing Product 0
8 American Standard 1660.14 User manual Plumbing Product 0
9 American Standard 2477 SERIES User manual Plumbing Product 3
10 American Standard 283 User manual Plumbing Product 0
11 American Standard 3352 User manual Plumbing Product 0
12 American Standard 3355 User manual Plumbing Product 0
13 American Standard 404 User manual Plumbing Product 0
14 American Standard 3351 User manual Plumbing Product 0
15 American Standard 3354 User manual Plumbing Product 0
16 Sony 26-483-01 User manual Plumbing Product 1
17 Sony SU-PF3M User manual Plumbing Product 1
18 Sony SU-PF3L User manual Plumbing Product 1
19 Sony YS-S100 User manual Plumbing Product 5
20 ACS GMB User manual Plumbing Product 0