Teledyne M201E user manual

User manual for the device Teledyne M201E

Device: Teledyne M201E
Category: Pet Fence
Manufacturer: Teledyne
Size: 0.38 MB
Added : 1/16/2014
Number of pages: 51
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Teledyne M201E. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Teledyne M201E.

For your convenience

If looking through the Teledyne M201E user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Teledyne M201E on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Teledyne M201E to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Teledyne M201E User manual - Online PDF
Advertisement
« Page 1 of 51 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Teledyne M201E but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Teledyne M201E. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1








MANUAL ADDENDUM


MODEL M201E
AMMONIA ANALYZER
(For use with the M200E Operators Manual, P/N 04410)









TELEDYNE ADVANCED POLLUTION INSTRUMENTATION
(TELEDYNE-API)
9480 CARROLL PARK DRIVE
SAN DIEGO, CA 92121-5201


TOLL-FREE: 800-324-5190
FAX: 858-657-9816
TEL: 858-657-9800
E-MAIL: api-sales@teledyne.com
WEB SITE: www.teledyne-api.com



Copyright 2006-2012 05206H DCN5910
Teledyne Advanced Pollution Instrumentation 07 May 2012

Summary of the content on the page No. 2

Summary of the content on the page No. 3

ABOUT THIS MANUAL This manual is an addendum that supplements the M200E NOx Analyzer manual, p/n 04410; it includes document(s) as listed below. Part No. Name/Description M201E Spare Parts List (in Section 6.0) 06185H Note: Please refer to our Website or Sales for more recent updates. NOTE We recommend that this manual and the M200E manual be read in their entirety before any attempt is made to operate the instrument. REVISION HISTORY M201E, MANUAL ADDENDUM, PN 05206 Date To

Summary of the content on the page No. 4

This page intentionally left blank. ii 05206H DCN5910

Summary of the content on the page No. 5

Teledyne API Model M201E NH Analyzer Operator Manual M201E Ammonia Analyzer 3 SAFETY MESSAGES Your safety and the safety of others is very important. We have provided many safety messages throughout this manual; please read these messages carefully. A safety message alerts you to potential hazards that could hurt you or others. Safety messages are associated with a safety alert symbol. These symbols are found in both the M200E and M201E manuals and are also located inside the instrument.

Summary of the content on the page No. 6

This page intentionally left blank. iv 05206H DCN5910

Summary of the content on the page No. 7

TABLE OF CONTENTS 1.0 M201E AMMONIA ANALYZER .............................................................7 1.1 Theory of Operation...................................................................................................... 10 1.1.1 Minimizing PMT Drift.......................................................................................... 11 1.1.2 Purging the Reaction Cell ..................................................................................... 12 1.2 Special C

Summary of the content on the page No. 8

Figure 3-6. Analog Output Manual Calibration............................................................................ 33 Figure 3-7. Analog Output Recorder Offset Calibration .............................................................. 34 Figure 4-1. Catalytic Cartridge ..................................................................................................... 36 Figure 4-2. Thermocouple Location ................................................................................

Summary of the content on the page No. 9

1.0 M201E AMMONIA ANALYZER This manual is to be used in conjunction with the M200E NO Analyzer x manual, p/n 04410 supplied with this instrument. It is important that you familiarize yourself with the workings of the NO analyzer before proceeding x with NH measurements. 3 The M201E ammonia analyzer consists of a modified M200E nitrogen oxide analyzer and an M501 NH , ammonia converter. The analyzer measures the 3 following individual gas concentrations: TNx (NH and NO ), NO (NO and NO

Summary of the content on the page No. 10

M201E Ammonia Analyzer Teledyne API Model M201E NH Analyzer Operator Manual 3 Figure 1-1. M201E Pneumatic Connection Diagram with External Calibrator Option (ECO) 8 05206H DCN5910

Summary of the content on the page No. 11

Teledyne API Model M201E NH Analyzer Operator Manual M201E Ammonia Analyzer 3 Figure 1-2. M201E and M501 NH , Pneumatic Flow 3 05206H DCN5910 9

Summary of the content on the page No. 12

M201E Ammonia Analyzer Teledyne API Model M201E NH Analyzer Operator Manual 3 Figure 1-3. M201E and M501 NH , with Zero and Span Valve Options Pneumatic Flow 3 1.1 THEORY OF OPERATION The Teledyne-API Model M201E analyzer measures ammonia by oxidizing it to nitric oxide by the following reaction: 4NH + 5O  4NO + 6H O 3 2 2 The resulting nitric oxide is then measured by the chemiluminescent reaction with ozone. Consult Section 10.1 in the M200E manual (provided with this instrum

Summary of the content on the page No. 13

Teledyne API Model M201E NH Analyzer Operator Manual M201E Ammonia Analyzer 3 and registered as NO . This location provides the drier with continuous flow, x thereby allowing it to stabilize faster. Note: Due to the Nafion® drier, the analyzer has a maximum ammonia range of 2.0 PPM. The calculated gas concentrations, ammonia and nitrogen dioxide, are computed from the differences between the measured channels, as outlined in the following equations: NO (Nitric Oxide) Concentration = Me

Summary of the content on the page No. 14

M201E Ammonia Analyzer Teledyne API Model M201E NH Analyzer Operator Manual 3 signal. This process improves zero baseline stability by minimizing the effect of PMT sensor drift. 1.1.2 Purging the Reaction Cell As with many chemical reactions the conversion of ammonia in the presence of other oxides of nitrogen is complicated. It is important to note that the valve DWELL time for an AZERO measurement has a default setting of 8 seconds. Shortening this value may not allow enough time to

Summary of the content on the page No. 15

Teledyne API Model M201E NH Analyzer Operator Manual M201E Ammonia Analyzer 3 These rules apply also to your calibrator’s internal plumbing. It is highly recommended that you use a M702SS calibrator in conjunction with the M201E. The calibrator has stainless steel plumbing throughout. The M700 calibrator contains Teflon tubing and internal MFC’s that can be affected by the ammonia gas, therefore, the M700 calibrator is not recommend for use with the M201E analyzer. It is important to k

Summary of the content on the page No. 16

M201E Ammonia Analyzer Teledyne API Model M201E NH Analyzer Operator Manual 3 1.4 M201E ANALYZER SPECIFICATIONS Table 1-1. M201E Operating Specifications 0-50 to 0-2000 ppb in 1 ppb increments (selectable, independent Ranges NH , NO, NO , NOx ranges supported) 3 2 3 3 Measurement Units PPB, PPM, microgram/m , milligram/m (user selectable) 1 Noise at Zero < 0.5 ppb RMS 1 < 1.0% of reading above 50 ppb Noise at Span Lower Detectable 1 ppb RMS 2 Limit 3, 6 2 ppb / 24 hours Zero Drif

Summary of the content on the page No. 17

2.0 CALIBRATION PROCEDURE This section begins with a high-level overview of the calibration procedure for the M201E analyzer. Details are provided starting in Section 2.1:  First, take the time to read the M200E manual to familiarize yourself with the Chemiluminescence process. It is important to remember that the analyzer is merely measuring different levels of nitric oxide sample gas on three separate channels (TN, NO , NO). The ammonia and nitrogen x x dioxide concentrations are the

Summary of the content on the page No. 18

Calibration Procedure Teledyne API Model M201E NH Analyzer Operator Manual 3 The first time bottled ammonia is connected to the gas dilution system, regulator/calibrator, the TNx reading may take a number of hours to stabilize. 2.1 ZEROING THE ANALYZER The analyzer can be zeroed by either applying zero air straight to the sample port or through the optional Zero/Span valves, if installed. It is important to remember that if the analyzer was previously sampling ammonia gas, prior to condu

Summary of the content on the page No. 19

Teledyne API Model M201E NH Analyzer Operator Manual Calibration Procedure 3 Table 2-2. Zero Calibration Procedure - Zero Gas Through ZERO Port Step No. Action Comment 1. Press CALZ The M201E enters the calibrate mode from sample mode. The zero gas is supplied through the ZERO inlet port on the rear panel of the M501 NH ,. 3 2 Table 2.1 Follow Steps 2 to 8 in Table 2-1. Notes:  Since the zero gas concentration is defined as 0 ppb, it is not necessary to enter the expected conc

Summary of the content on the page No. 20

Calibration Procedure Teledyne API Model M201E NH Analyzer Operator Manual 3 operator then manually spans the TN and NO channels individually through the x x user interface. The following Tables outline the manual steps necessary to span the analyzer. Table 2-3. NO Calibration Procedure – NO Gas Through the SAMPLE Port Important: Each channel (TN and NO ) must be Spanned individually x x Step No. Action Comment 1. Press CAL The M201E enters the calibrate mode from sample mode. Confirm


Alternative user manuals
# User manual Category Download
1 Teledyne 201A User manual Pet Fence 1
2 Teledyne t7000 User manual Pet Fence 0
3 Teledyne t700e User manual Pet Fence 0
4 Sony XL-2100U User manual Pet Fence 1
5 Sony XL-2200 User manual Pet Fence 1
6 ACS A0573713 User manual Pet Fence 1
7 Aiphone gt-op2 User manual Pet Fence 0
8 Aiphone gt-op3 User manual Pet Fence 0
9 Aiphone HID-SS User manual Pet Fence 0
10 Aiphone SBX-LSE User manual Pet Fence 0
11 Brother Z-8550A User manual Pet Fence 13
12 Black Box VDSL2 PoE Ethernet Extener Kid, PD User manual Pet Fence 0
13 Black Box LBPD01A-KIT User manual Pet Fence 2
14 Cardinal Gates XTG User manual Pet Fence 0
15 CyberPower Systems OL8K10KRT3UTF User manual Pet Fence 2