Bryant DELUXE 13 SEER 550A user manual

User manual for the device Bryant DELUXE 13 SEER 550A

Device: Bryant DELUXE 13 SEER 550A
Category: Air Conditioner
Manufacturer: Bryant
Size: 0.65 MB
Added : 11/14/2014
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant DELUXE 13 SEER 550A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant DELUXE 13 SEER 550A.

For your convenience

If looking through the Bryant DELUXE 13 SEER 550A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant DELUXE 13 SEER 550A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant DELUXE 13 SEER 550A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant DELUXE 13 SEER 550A User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant DELUXE 13 SEER 550A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant DELUXE 13 SEER 550A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


DELUXE 13 SEER
550A
AIR CONDITIONER
®
WITH PURON REFRIGERANT
Sizes 024 thru 060
on production of most other refrigerants which has scheduled
reductions beginning in 2004. The resulting cap in production
ultimately results in a complete ban on many other refrigerants
in new equipment by the year 2010. These changes required by
federal law, mean the supply of other refrigerants may be limited
in the near future making Puron refrigerant the correct ch

Summary of the content on the page No. 2

DIMENSIONS —2— 3 /8" DIA. TIEDOWN KNOCKOUTS (2) PLACES 7 FIELD POWER SUPPLY CONN. /8" DIA. C 1 HOLE WITH 1 /8" DIA. KNOCKOUT L 1 2 /2" 3 AND 1 /8" DIA. KNOCKOUT AIR DISCHARGE B AIR IN 9 1 /16" AIR DISCHARGE FIELD CONTROL ACCESS K SUPPLY CONN PANEL 7 /8" DIA. HOLE D H DIA. VAPOR A C AIR IN L LINE CONN. G 3 /8" DIA. LIQUID E F LINE CONN. 1 10 /2" M 3 4 /16" AIR DISCHARGE J AIR IN 1 1 /4" N 3 1 /4" NOTES: 1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE

Summary of the content on the page No. 3

H T G I N W I G N N O I I Y T L I P D M N O O C A C S R A I R I E S I R A Q T A U A O I N T P RECOMMENDED TUBE DIAMETERS Liquid Tube Diameter (In.) Vapor Tube Diameter (In.) UNIT 0 to 50 Ft 0 to 50 Ft Long-Line Applications* SIZE Tube Length Long-Line Applications* Tube Length (Maximum Diameter) 024 5/8 7/8 030, 036 3/4 7/8 3/8 3/8 042, 048 7/8 1-1/8 060 1-1/8 1-1/8 *For tube sets greater than 50 ft horizontal and/or 20 ft vertical differential, co

Summary of the content on the page No. 4

SPECIFICATIONS UNIT SIZE-SERIES 024-G 030-F 036-F/G Operating Weight (Lb) 214 202 237 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 Operating Voltage Range* 187—253 Compressor— Rated Load Amps 12.8 14.7 15.4/16.7 Locked Rotor Amps 60.0 72.5 83.0/79.0 Condenser Fan Motor—Full Load Amps 0.80 0.80 1.1 Min Unit Ampacity for Wire Sizing 16.8 19.2 20.2/22.0 Min Wire Size (60°C Copper) AWG† 14 14 12 Min Wire Size (75°C Copper) AWG† 14 14 12 Max Wire Length (Ft) (60°C Copper)‡ 46 41 62/57

Summary of the content on the page No. 5

SPECIFICATIONS Continued UNIT SIZE-SERIES 042-F 048-F 060-H Operating Weight (Lb) 247 295 331 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 Operating Voltage Range* 187—253 Compressor— Rated Load Amps 18.6 20.5 27.6 Locked Rotor Amps 105.0 109.0 158.0 Condenser Fan Motor—Full Load Amps 1.1 1.4 1.4 Min Unit Ampacity for Wire Sizing 24.4 27.0 35.9 Min Wire Size (60°C Copper) AWG† 10 10 8 Min Wire Size (75°C Copper) AWG† 10 10 8 Max Wire Length (Ft) (60°C Copper)‡ 80 73 85 Max Wire

Summary of the content on the page No. 6

EVOLUTION™* CONTROLS DESCRIPTION ACCESSORY Evolution Control Deluxe 7-Day Programmable (Wall-mounted system control.) SYSTXBBUID01 Evolution Zone Control Deluxe Zoning 7-Day Programmable (Wall-mounted control for a Z SYSTXBBUIZ01 multi-zone system.) O Evolution 4-Zone Damper Control Module (Wall-mounted control for a four-zone system.) SYSTXBB4ZC01 N I Evolution Smart Sensor (Optional wall control used to monitor temperature and/or fan control SYSTXBBSMS01 in an individual

Summary of the content on the page No. 7

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient applications. Required in long line applications. Suggested in all commercial applications. 6. Evaporator Freeze Thermostat An SPST temperatur

Summary of the content on the page No. 8

COMBINATION RATINGS SEER FACTORY- TOT. SUPPLIED Bryant Gas UNIT INDOOR CAP. ENHANCE- Standard Furnace or Accessory SIZE-SERIES MODEL BTUH MENT Rating Accessory TDR† Puron TXV‡ EER *CC5A/CD5AA030 23,000 NONE — 13.00 13.00 11.25 CC5A/CD5AA024 22,800 NONE — 12.50 12.50 11.15 CC5A/CD5AW024 22,800 NONE — 12.50 12.50 11.15 CC5A/CD5AW030 23,000 NONE — 13.00 13.00 11.25 CE3AA024 22,800 NONE — 12.50 12.50 11.25 CE3AA030 23,000 NONE — 13.00 13.00 11.35 CF5AA024 22,800 NONE — 12.50 12.50 11.

Summary of the content on the page No. 9

COMBINATION RATINGS Continued SEER FACTORY- TOT. SUPPLIED Bryant Gas UNIT INDOOR CAP. ENHANCE- Standard Furnace or Accessory SIZE-SERIES MODEL BTUH MENT Rating Accessory TDR† Puron TXV‡ EER COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CE3AA024 22,400 TDR 14.00 — 14.00 12.30 CE3AA030 22,800 TDR 14.00 — 14.00 12.55 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CE3AA024 22,400 TDR 14.00 — 14.00 12.20 CE3AA030 22,800 TDR 14.00 — 14.00 12.45 COILS + 355MAV042060 VARIABLE-SPEED

Summary of the content on the page No. 10

COMBINATION RATINGS Continued SEER FACTORY- TOT. SUPPLIED Bryant Gas UNIT INDOOR CAP. ENHANCE- Standard Furnace or Accessory SIZE-SERIES MODEL BTUH MENT Rating Accessory TDR† Puron TXV‡ EER FF1DNA030 28,600 TDR 12.50 — 12.50 11.05 FG3AAA036 28,400 NONE — 12.50 12.50 11.00 FK4(C,D)NF001 29,000 TDR&TXV 13.00 — — 11.95 FK4(C,D)NF002 29,000 TDR&TXV 13.50 — — 12.05 FK4(C,D)NF003 29,600 TDR&TXV 14.00 — — 12.40 FV4(A,B)NF002 29,000 TDR&TXV 13.50 — — 12.05 FV4(A,B)NF003 29,600 TDR&TX

Summary of the content on the page No. 11

COMBINATION RATINGS Continued SEER FACTORY- TOT. SUPPLIED Bryant Gas UNIT INDOOR CAP. ENHANCE- Standard Furnace or Accessory SIZE-SERIES MODEL BTUH MENT Rating Accessory TDR† Puron TXV‡ EER COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,600 TDR 13.50 — 13.50 11.90 CC5A/CD5AW030 28,400 TDR 13.20 — 13.20 11.50 CE3AA030 29,000 TDR 13.20 — 13.20 11.65 CE3AA036 29,200 TDR 13.50 — 13.50 11.75 CK3BA030 28,400 TDR 13.20 — 13.20 11.45 CK3BA036 29,600 TDR 13.50 — 13.50 11.95

Summary of the content on the page No. 12

COMBINATION RATINGS Continued SEER FACTORY- TOT. SUPPLIED Bryant Gas ENHANCE- Standard Furnace or UNIT INDOOR CAP. Accessory SIZE-SERIES MODEL BTUH MENT Rating Accessory TDR† Puron TXV‡ EER CK5PE042 35,000 TDR&TXV 14.00 — — 12.20 CK5PT036 35,000 TDR&TXV 13.50 — — 12.05 CK5PT042 35,000 TDR&TXV 14.00 — — 12.15 CK5PW036 35,000 TDR&TXV 13.50 — — 12.05 COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 14.00 — 14.00 12.00 CC5A/CD5AA042 35,000 TDR 14.00 — 14.00 12.05 CC5A/CD5AW

Summary of the content on the page No. 13

COMBINATION RATINGS Continued SEER FACTORY- TOT. SUPPLIED Bryant Gas UNIT INDOOR CAP. ENHANCE- Standard Furnace or Accessory SIZE-SERIES MODEL BTUH MENT Rating Accessory TDR† Puron TXV‡ EER CK3BA042 35,000 TDR 13.50 — 13.50 11.75 CK5A/CK5BA042 35,000 TDR 13.50 — 13.50 11.75 CK5A/CK5BT042 35,000 TDR 13.50 — 13.50 11.75 CK5A/CK5BW036 35,000 TDR 13.20 — 13.20 11.60 CK5PA042 35,000 TDR&TXV 13.50 — — 11.75 CK5PT042 35,000 TDR&TXV 13.50 — — 11.75 CK5PW036 35,000 TDR&TXV 13.20 — — 11.60 COILS + 355MA

Summary of the content on the page No. 14

COMBINATION RATINGS Continued SEER FACTORY- TOT. SUPPLIED Bryant Gas UNIT INDOOR CAP. ENHANCE- Standard Furnace or Accessory SIZE-SERIES MODEL BTUH MENT Rating Accessory TDR† Puron TXV‡ EER FV4BNF003 35,000 TDR&TXV 14.00 — — 12.40 FV4BNF005 36,000 TDR&TXV 14.50 — — 12.85 FX4BNF036 35,000 TDR&TXV 12.50 — — 11.20 FX4BNF042 35,600 TDR&TXV 13.00 — — 11.40 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA036 34,400 TDR 13.50 — 13.50 11.85 CE3AA036 34,000 TDR 13.50 — 13.50 11.70 CE3AA042 34

Summary of the content on the page No. 15

COMBINATION RATINGS Continued SEER FACTORY- TOT. SUPPLIED Bryant Gas ENHANCE- Standard Furnace or UNIT INDOOR CAP. Accessory SIZE-SERIES MODEL BTUH MENT Rating Accessory TDR† Puron TXV‡ EER COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,400 TDR 13.50 — 13.50 11.85 CC5A/CD5AW036 34,400 TDR 13.50 — 13.50 11.85 CC5A/CD5AW042 33,800 TDR 13.50 — 13.50 11.75 CE3AA036 34,000 TDR 13.50 — 13.50 11.65 CE3AA042 34,600 TDR 13.50 — 13.50 11.90 CK3BA042 34,600 TDR 13.50 — 13.50 11.90 CK5A/CK5B

Summary of the content on the page No. 16

COMBINATION RATINGS Continued SEER FACTORY- TOT. SUPPLIED Bryant Gas CAP. ENHANCE- Standard Furnace or UNIT INDOOR Accessory SIZE-SERIES MODEL BTUH MENT Rating Accessory TDR† Puron TXV‡ EER CK3BA036 34,600 TDR 13.50 — 13.50 12.00 CK3BA042 34,600 TDR 13.50 — 13.50 12.05 CK5A/CK5BA036 34,600 TDR 13.50 — 13.50 12.00 CK5A/CK5BA042 34,600 TDR 13.50 — 13.50 12.05 CK5A/CK5BE042 34,600 TDR 13.50 — 13.50 12.15 CK5A/CK5BT036 34,600 TDR 13.50 — 13.50 12.00 CK5A/CK5BT042 34,600 TDR 13.50 — 13.50 12.05 CK5

Summary of the content on the page No. 17

COMBINATION RATINGS Continued SEER FACTORY- TOT. SUPPLIED Bryant Gas UNIT INDOOR CAP. ENHANCE- Standard Furnace or Accessory Accessory TDR† Puron TXV‡ SIZE-SERIES MODEL BTUH MENT Rating EER CC5A/CD5AW048 40,500 TDR 14.00 — 14.00 11.95 CD5AA048 40,500 TDR 14.00 — 14.00 11.90 CE3AA042 40,500 TDR 13.50 — 13.50 11.85 CE3AA048 41,000 TDR 13.50 — 13.50 11.90 CK3BA042 40,500 TDR 13.50 — 13.50 11.80 CK3BA048 40,500 TDR 14.00 — 14.00 12.00 CK5A/CK5BA042 40,500 TDR 13.50 — 13.50 11.80 CK5A/CK5BA048 40,5

Summary of the content on the page No. 18

COMBINATION RATINGS Continued SEER FACTORY- TOT. SUPPLIED Bryant Gas UNIT INDOOR CAP. ENHANCE- Standard Furnace or Accessory SIZE-SERIES MODEL BTUH MENT Rating Accessory TDR† Puron TXV‡ EER CK5PT042 40,500 TDR&TXV 13.00 — — 11.30 CK5PT048 40,500 TDR&TXV 13.20 — — 11.55 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,500 TDR 13.20 — 13.20 11.50 CC5A/CD5AC048 40,000 TDR 13.20 — 13.20 11.55 CD5AA048 40,500 TDR 13.50 — 13.50 11.75 CE3AA042 41,000 TDR 13.20 — 13.20 11.60 CE3AA048 41,00

Summary of the content on the page No. 19

COMBINATION RATINGS Continued SEER FACTORY- TOT. SUPPLIED Bryant Gas UNIT INDOOR CAP. ENHANCE- Standard Furnace or Accessory SIZE-SERIES MODEL BTUH MENT Rating Accessory TDR† Puron TXV‡ EER COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE CC5A/CD5AA060 46,000 TDR 13.00 — 13.00 12.00 CC5A/CD5AC048 45,000 TDR 13.00 — 13.00 11.70 CC5A/CD5AW048 45,500 TDR 13.50 — 13.50 11.95 CD5AA048 45,500 TDR 13.50 — 13.50 11.95 CE3AA048 46,000 TDR 13.00 — 13.00 11.95 CE3AA060 47,000 TDR 14.00 — 14.00 12.35 CK3BA

Summary of the content on the page No. 20

COMBINATION RATINGS Continued SEER FACTORY- TOT. SUPPLIED Bryant Gas UNIT INDOOR CAP. ENHANCE- Standard Furnace or Accessory SIZE-SERIES MODEL BTUH MENT Rating Accessory TDR† Puron TXV‡ EER CK5PA060 46,500 TDR&TXV 13.00 — — 11.70 CK5PT060 46,500 TDR&TXV 13.00 — — 11.70 CK5PX060 47,500 TDR&TXV 13.50 — — 12.05 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AA060 46,500 TDR 13.00 — 13.00 11.55 CC5A/CD5AW048 46,000 TDR 13.00 — 13.00 11.50 CC5A/CD5AW060 47,000 TDR 13.50 — 13.50 12.00 CE3AA048


Alternative user manuals
# User manual Category Download
1 Bryant 113A User manual Air Conditioner 365
2 Bryant 24B User manual Air Conditioner 61
3 Bryant 187B User manual Air Conditioner 39
4 Bryant 342S User manual Air Conditioner 17
5 Bryant 39479D8 User manual Air Conditioner 31
6 Bryant 342 User manual Air Conditioner 15
7 Bryant 165A User manual Air Conditioner 22
8 Bryant 450D User manual Air Conditioner 21
9 Bryant 451P User manual Air Conditioner 7
10 Bryant 451 User manual Air Conditioner 7
11 Bryant 36-453 User manual Air Conditioner 10
12 Bryant 452W User manual Air Conditioner 6
13 Bryant 452 User manual Air Conditioner 3
14 Bryant 454 User manual Air Conditioner 112
15 Bryant 463AAC008BA User manual Air Conditioner 17
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21