Bryant DE LUXE 12 SEER 552A user manual

User manual for the device Bryant DE LUXE 12 SEER 552A

Device: Bryant DE LUXE 12 SEER 552A
Category: Air Conditioner
Manufacturer: Bryant
Size: 0.26 MB
Added : 11/14/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant DE LUXE 12 SEER 552A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant DE LUXE 12 SEER 552A.

For your convenience

If looking through the Bryant DE LUXE 12 SEER 552A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant DE LUXE 12 SEER 552A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant DE LUXE 12 SEER 552A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant DE LUXE 12 SEER 552A User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant DE LUXE 12 SEER 552A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant DE LUXE 12 SEER 552A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


DELUXE 12 SEER
552A (60 Hz)
AIR CONDITIONER
®
WITH PURON REFRIGERANT
Sizes 018 thru 060
on production of most other refrigerants which has scheduled
reductions beginning in 2004. The resulting cap in production
ultimately results in a complete ban on many other refrigerants
in new equipment by the year 2010. These changes, required by
federal law, mean the supply of other refrigerants may be limited
in the near future making Puron the correct choic

Summary of the content on the page No. 2

DIMENSIONS —2— 3 /8" DIA. TIEDOWN KNOCKOUTS (2) PLACES 7 FIELD POWER SUPPLY CONN. /8" DIA. C 1 HOLE WITH 1 /8" DIA. KNOCKOUT L 1 2 /2" 3 AND 1 /8" DIA. KNOCKOUT AIR DISCHARGE B AIR IN 9 1 /16" AIR DISCHARGE FIELD CONTROL ACCESS K SUPPLY CONN 7 PANEL /8" DIA. HOLE D H DIA. VAPOR A C AIR IN L LINE CONN. G 3 /8" DIA. LIQUID E F LINE CONN. 1 10 /2" M 3 4 /16" AIR DISCHARGE J AIR IN 1 1 /4" N 3 1 /4" NOTES: 1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE

Summary of the content on the page No. 3

H T G I N W I G N N O I I Y T L I P D M N O O C A C S R A I R I E S I R A Q T A U A O I N T P RECOMMENDED TUBE DIAMETERS Liquid Tube Diameter (In.) Vapor Tube Diameter (In.) UNIT 0 to 50 Ft 0 to 50 Ft Long-Line Applications* SIZE Tube Length Long-Line Applications* Tube Length (Maximum Diameter) 018 5/8 3/4 024 5/8 3/4 030, 036 3/8 3/8 3/4 7/8 042, 048 7/8 1-1/8 060 1-1/8 1-1/8 * For tube sets greater than 50 ft and/or 20 ft vertical differen

Summary of the content on the page No. 4

SPECIFICATIONS UNIT SIZE-SERIES 018-F 024-F/G 030-F 036-F/G Operating Weight (Lb) 168 209 209 212 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 Operating Voltage Range* 187—253 Compressor— Rated Load Amps 10.3 13.5/12.8 14.7 16.7/15.4 Locked Rotor Amps 51.0 61.0/60.0 72.5 87.5/83.0 Condenser Fan Motor—Full Load Amps 0.50 0.50/0.80 0.80 0.8 Min Unit Ampacity for Wire Sizing 13.4 17.4/16.8 19.2 21.7/20.1 Min Wire Size (60°C Copper) AWG† 14 14 14 12 Min Wire Size (75°C Copper) AWG† 1

Summary of the content on the page No. 5

SPECIFICATIONS Continued UNIT SIZE-SERIES 042-F 048-F 060-F Operating Weight (Lb) 213 215 278 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 Operating Voltage Range* 187—253 Compressor—Rated Load Amps 18.6 20.5 27.6 Locked Rotor Amps 105.0 109.0 158.0 Condenser Fan Motor—Full Load Amps 1.1 1.1 1.4 Min Unit Ampacity for Wire Sizing 24.4 26.7 35.9 Min Wire Size (60°C Copper) AWG† 10 10 8 Min Wire Size (75°C Copper) AWG† 10 10 8 Max Wire Length (Ft) (60°C Copper)‡ 81 74 86 Max Wire

Summary of the content on the page No. 6

ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR REQUIRED FOR LOW-AMBIENT LONG-LINE SEA COAST APPLICATIONS APPLICATIONS* APPLICATIONS ACCESSORY (Below 55°F) (Over 50 Ft) (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes† No No Accumulator No No No Compressor Start Assist Yes Yes No Capacitor and Relay MotorMaster® Control or Yes No No Low-Ambient Pressure Switch Wind Baffle See Low-Ambient Instructions No No C

Summary of the content on the page No. 7

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued 10. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 200 psig to 365 psig). The control will maintain working head pressure at low-ambient temperatures down to 0°F (–17.8°C) when properly installed. SUGGESTED USE: Cooling ope

Summary of the content on the page No. 8

COMBINATION RATINGS SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† Puron TXV‡ EER *CK5A/CK5BA024 17,500 NONE — 12.00 12.00 10.80 CC5A/CD5AA018 17,200 NONE — 11.50 11.50 10.45 CC5A/CD5AA024 17,500 NONE — 12.00 12.00 10.70 CC5A/CD5AW024 17,500 NONE — 12.00 12.00 10.70 CE3AA024 17,500 NONE — 12.00 12.00 10.75 CF5AA024 17,500 NONE — 12.00 12.00 10.75 CK3BA024 17,500 NONE — 12.00 12.00 10.80

Summary of the content on the page No. 9

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† Puron TXV‡ EER CK5A/CK5BW030 23,200 TDR 13.00 — 13.00 11.20 CK5PA024 23,000 TDR&TXV 12.50 —— 11.10 CK5PA030 23,200 TDR&TXV 13.00 —— 11.20 CK5PW024 23,000 TDR&TXV 12.50 —— 11.10 CK5PW030 23,200 TDR&TXV 13.00 —— 11.20 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AW030 23,200 TDR 13.00 — 13.00 11.05 CK5

Summary of the content on the page No. 10

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† Puron TXV‡ EER CE3AA030 22,600 TDR 13.00 — 13.00 11.80 CK3BA024 22,200 TDR 13.00 — 13.00 11.85 CK3BA030 22,600 TDR 13.00 — 13.00 11.90 CK5A/CK5BA024 22,200 TDR 13.00 — 13.00 11.70 CK5A/CK5BA030 22,600 TDR 13.00 — 13.00 11.80 CK5A/CK5BW024 22,200 TDR 13.00 — 13.00 11.75 CK5A/CK5BW030 22,600 TDR 13.00 —

Summary of the content on the page No. 11

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory BTUH MENT Rating TDR† Puron TXV‡ EER SIZE-SERIES UNIT CK5A/CK5BW030 22,600 TDR 13.00 — 13.00 11.80 CK5PW024 22,200 TDR&TXV 13.00 —— 11.65 CK5PW030 22,600 TDR&TXV 13.00 —— 11.75 024-G COILS + 315(A,J)AV060120 VARIABLE-SPEED FURNACE CE3AA024 22,200 TDR 13.00 — 13.00 11.45 CE3AA030 22,600 TDR 13.00 — 13.00 11.70 *CK5A/CK5BA036 29,000 NONE — 12.00 12.00 1

Summary of the content on the page No. 12

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† Puron TXV‡ EER CK5PW036 29,000 TDR&TXV 13.00 —— 11.60 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,000 TDR 13.00 — 13.00 11.25 CC5A/CD5AW030 28,000 TDR 12.50 — 12.50 10.80 CK3BA030 28,000 TDR 12.50 — 12.50 10.85 CK3BA036 29,000 TDR 13.00 — 13.00 11.30 CK5A/CK5BA036 29,000 TDR 13.00 — 13.00 11.30 CK5A/CK5BW0

Summary of the content on the page No. 13

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† Puron TXV‡ EER CK5A/CK5BT036 34,600 TDR 12.50 — 12.50 11.15 CK5PA036 34,600 TDR&TXV 12.50 —— 11.15 CK5PE042 34,600 TDR&TXV 12.50 —— 11.25 CK5PT036 34,600 TDR&TXV 12.50 —— 11.15 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA036 34,600 TDR 12.50 — 12.50 11.30 CC5A/CD5AA042 34,600 TDR 13.00 — 13.00 11.40 CC5A/CD5A

Summary of the content on the page No. 14

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† Puron TXV‡ EER CK3BA042 34,600 TDR 12.50 — 12.50 11.20 CK5A/CK5BA036 34,600 TDR 12.50 — 12.50 11.15 CK5PA036 34,600 TDR&TXV 12.50 —— 11.15 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,600 TDR 12.50 — 12.50 11.25 CC5A/CD5AW036 34,600 TDR 12.50 — 12.50 11.20 CK3BA042 34,600 TDR 12.50 — 12.50 11.25 CK5A/CK5BA0

Summary of the content on the page No. 15

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† Puron TXV‡ EER CK5PA042 39,000 TDR&TXV 12.50 —— 10.85 CK5PA048 39,500 TDR&TXV 12.50 —— 10.95 CK5PE042 39,500 TDR&TXV 12.50 —— 10.90 CK5PT042 39,000 TDR&TXV 12.50 —— 10.85 CK5PT048 39,500 TDR&TXV 12.50 —— 10.95 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.50 — 12.50 10.95 CC5A/CD5AC048 39,000

Summary of the content on the page No. 16

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† Puron TXV‡ EER CC5A/CD5AC048 39,000 TDR 12.50 — 12.50 10.65 CD5AA048 39,500 TDR 12.50 — 12.50 10.80 CK3BA042 39,000 TDR 12.50 — 12.50 10.75 CK3BA048 39,500 TDR 12.50 — 12.50 10.85 CK5A/CK5BA042 39,000 TDR 12.50 — 12.50 10.75 CK5A/CK5BA048 39,500 TDR 12.50 — 12.50 10.85 CK5PA042 39,000 TDR&TXV 12.50 —— 10.75 CK5PA048 39,500

Summary of the content on the page No. 17

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† Puron TXV‡ EER CK5PA048 44,500 TDR&TXV 12.00 —— 10.60 CK5PT048 44,500 TDR&TXV 12.00 —— 10.60 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,000 TDR 12.50 — 12.50 10.85 CC5A/CD5AC048 44,000 TDR 12.00 — 12.00 10.70 CC5A/CD5AW048 44,500 TDR 12.50 — 12.50 10.80 CD5AA048 44,500 TDR 12.00 — 12.00 10.80 CD5PX060

Summary of the content on the page No. 18

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† Puron TXV‡ EER CK5PX060 46,000 TDR&TXV 12.00 —— 10.70 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA060 44,500 TDR 12.00 — 12.00 10.55 CC5A/CD5AC048 44,000 TDR 12.00 — 12.00 10.40 CC5A/CD5AW060 45,500 TDR 12.50 — 12.50 10.85 CD5AA048 44,500 TDR 12.00 — 12.00 10.55 CK3BA048 44,500 TDR 12.00 — 12.00 10.60 CK3BA060 45

Summary of the content on the page No. 19

* Tested combination. † In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR. ‡ TXV must be Puron® compatible and hard shutoff type. EER — Energy Efficiency Ratio SEER — Seasonal Energy Efficiency Ratio TDR — Time-Delay Relay TXV — Puron® Thermostatic Expansion Valve NOTES: 1. Ra

Summary of the content on the page No. 20

DETAILED COOLING CAPACITIES* CONDENSER ENTERING AIR TEMPERATURES °F EVAP AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** 552AN018-F Outdoor Section With CK5A/CK5BA024 Indoor Section 72 19.79 10.21 1.30 19.80 10.35 1.46 19.29 10.26 1.63 18.30 9.92 1.82 17.10


Alternative user manuals
# User manual Category Download
1 Bryant 113A User manual Air Conditioner 365
2 Bryant 24B User manual Air Conditioner 61
3 Bryant 187B User manual Air Conditioner 39
4 Bryant 342S User manual Air Conditioner 17
5 Bryant 39479D8 User manual Air Conditioner 31
6 Bryant 342 User manual Air Conditioner 15
7 Bryant 165A User manual Air Conditioner 22
8 Bryant 450D User manual Air Conditioner 21
9 Bryant 451P User manual Air Conditioner 7
10 Bryant 451 User manual Air Conditioner 7
11 Bryant 36-453 User manual Air Conditioner 10
12 Bryant 452W User manual Air Conditioner 6
13 Bryant 452 User manual Air Conditioner 3
14 Bryant 454 User manual Air Conditioner 112
15 Bryant 463AAC008BA User manual Air Conditioner 17
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21