Bryant 116B user manual

User manual for the device Bryant 116B

Device: Bryant 116B
Category: Air Conditioner
Manufacturer: Bryant
Size: 1.4 MB
Added : 11/14/2014
Number of pages: 22
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant 116B. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant 116B.

For your convenience

If looking through the Bryant 116B user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant 116B on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant 116B to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant 116B User manual - Online PDF
Advertisement
« Page 1 of 22 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant 116B but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant 116B. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

116B
Legacyt Line 16 Air Conditioner
with Puronr Refrigerant
1--1/2 to 5 Nominal Tons
Product Data
INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S 14 -- 16.5 SEER/11.0-- 13.5 EER
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S Sound level as low as 76 dBA
S Sound level as low as 74 dBA with accessory sound
blanket
Comfort
S System supports Edger Thermidistatt or standard
thermostat controls
Reliability
S Puronr refrigerant -- environmentally soun

Summary of the content on the page No. 2

MODEL NUMBER NOMENCLATURE 12 34 5 6 78 9 10 1112 14 N N N A A/N N N N N A/N A/N N A 11 6B N A 03 60 0 0 0 Prod- Major Grille CoolingCapacity uct Tier SEER Voltage Open Open Open Series Series Variations Family N= 1= 0=Not 208---230---1 0=Not 0=Not Legacy Defined 1=AC 6=16 SEER B=Puron A=Dense or Defined Defined RNC 208/230---1 ISO 9001:2000 the environmentally sound refrigerant REGISTERED Use of the AHRI Certified TM Mark indicates a Thisproduct hasbeen designedandmanufacturedto manufacturer’s

Summary of the content on the page No. 3

REFRIGERANT PIPING LENGTH LIMITATIONS { Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puronr Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths : Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit Liquid AC withPuronRefrigerantMaximumTotalEquivalentLength{: OutdoorunitBELOW

Summary of the content on the page No. 4

REFRIGERANT CHARGE ADJUSTMENTS LiquidLine Size PuronCharge oz/ft 0.60 3/8 (Factory chargefor lineset=9oz) 5/16 0.40 1/4 0.27 Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or diameter liquid lines, charge adjustments are required per the chart above. Charging Formula: [(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment Example 1: System has 15 ft of line set using existing 1/4“ liq

Summary of the content on the page No. 5

ACCESSORY THERMOSTATS PART NUMBER PROGRAM GAS ELECTRIC HEAT COOL T2---PAC01 5---2 Day √ √ 1 1 T2---NAC01 NP √ √ 1 1 T2SNAC01 NP 1 1 √ √ THERMOSTATACCESSORIES PART NUMBER BRIEFDESCRIPTION THERMOSTATSUSEDWITH ThermostatConversion Kit(4 to 5 wire) --- 10 TSTATXXCNV10 All Bryantrbrandedthermostats pack TX---LBP01 LargeDecorativeBackplate T6---Pxx, T6---Nxx, and T2---Pxx TX---MBP01 Medium Decorative Backplate T2---Nxx and T1---Pxx ACCESSORIES UnitSizes --- Series KITNUMBER DESCRIPTION 018---B 024---A

Summary of the content on the page No. 6

ACCESSORY USAGE GUIDELINE REQUIREDFORLONG REQUIREDFOR REQUIREDFORLOW---AMBI- LINE SEACOAST ACCESSORY ENTCOOLINGAPPLICATIONS APPLICATIONS* APPLICATIONS (Below55 °F/12.8_C) (Over80ft./24.38m) (Within2miles/3.22km) BallBearingFanMotor Yes{ No No CompressorStartAssistCapacitorandRelay Yes Yes No CrankcaseHeater Yes Yes No EvaporatorFreezeThermostat Yes No No Hard Shut---Off TXV Yes Yes Yes LiquidLineSolenoidValve No No No ® Motor Master Control or Yes No No Low---ambient Pressure Switch SupportFeet

Summary of the content on the page No. 7

Accessory Description and Usage (Listed Alphabetically) (Continued) 10. Sound Hood 13. Time--Delay Relay Wraparound sound reducing cover for the compressor. Reduces An SPST delay relay which briefly continues operation of indoor the sound level by about 2 dBA. blower motor to provide additional cooling after the compressor cycles off. Usage Guideline: NOTE: Most indoor unit controls include this feature. For those Suggested when unit is installed closer than 15 ft (4.57 m) to that do not, use th

Summary of the content on the page No. 8

ELECTRICAL DATA MAX MAX OPERVOLTS* COMPR FAN MINWIRE MINWIRE MAXFUSE** LENGTH LENGTH UNITSIZE V/PH MCA SIZE{ SIZE{ orCKTBRK ft.(m)} ft.(m)} MAX MIN LRA RLA FLA 60 ° C 75 ° C AMPS 60 ° C 75 ° C 018---B 48.0 9.0 0.50 11.8 14 14 67(20.4) 64(19.5) 20 024---A 58.3 13.5 0.75 17.7 14 14 46(14.0) 43(13..1) 25 030---A 64.0 12.8 0.75 16.8 14 14 44(13.4) 41(12.5) 25 036---A 77.0 14.1 0.50 18.1 12 12 57(17.4) 54(16.5) 30 042---A 112.0 17.9 1.20 23.6 10 10 85(25.9) 81(24.7) 40 208/230/1---60 253 197 048---B

Summary of the content on the page No. 9

9 DIMENSIONS -- ENGLISH ELECTRICAL OPERATING SHIPPING SHIPPING UNIT SERIES AB C D E F G K L M N P CHARACTERISTICS WEIGHT (lbs) WEIGHT (lbs) DIMENSIONS (L x W x H) 116BNA018 A X O O O 23 1/8" 28 11/16" 3 3/4" 3/4" 4 7/16" 18 1/16" 7 13/16" 2 13/16" 1/2" 13" 12" 13" 118 141 24 1/4" X 27 3/8" X 32 9/16" 116BNA024 A X O O O 31 3/16" 28 5/16" 3 3/4" 3/4" 6 9/16" 24 11/16" 9 1/8" 2 13/16" 1/2" 16" 16" 13" 147 183 32 3/8" X 35 1/2" X 32 9/16" 116BNA030 A X O O O 31 3/16" 32 5/16" 3 3/4" 3/4" 6 9/16" 24

Summary of the content on the page No. 10

10 116B DIMENSIONS -- SI ELECTRICAL OPERATING SHIPPING SHIPPING UNIT SERIES AB C D E F G K L M N P CHARACTERISTICS WEIGHT (Kgs) WEIGHT (Kgs) DIMENSIONS (L x W x H) 116BNA018 A X O O O 587.3 728.7 95.2 19.0 112.7 458.8 198.4 71.4 12.7 330.2 304.8 330.2 53.4 64.0 616.0 X 695.3 X 827.1 116BNA024 A X O O O 792.2 719.2 95.2 19.0 166.7 627.1 231.8 71.4 12.7 406.4 406.4 330.2 66.5 82.8 822.3 X 901.7 X 827.1 116BNA030 A X O O O 792.2 820.8 95.2 19.0 166.7 627.1 231.8 71.4 12.7 393.7 406.4 362.0 69.3 85.

Summary of the content on the page No. 11

Wall 11 CLEARANCES Clearances (various examples) Wall Wall 6” 24” (152.4) (609.6) Service 24” 12” (609.6) (304.8) Service 12” 6” (304.8) (152.4) 12” (304.8) 12” (304.8) Wall 24” 24” 24” (609.6) (609.6) (609.6) Service Service Service 18” 18” 18” (457.2) (457.2) (457.2) Note: Numbers in ( ) = mm IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re--circulation of discharge air. 116B

Summary of the content on the page No. 12

TESTED AHRI COMBINATION RATINGS* NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Bryant database at: http://cactaxcredits.info/bryant-ratings/hp_ratings_srch.php Equipment performance calculator can be accessed at: http://rpmobbry.wrightsoft.com/ ModelNumber IndoorCoilModelNumber FurnaceModelNumber CoolingCapacity E

Summary of the content on the page No. 13

13 DETAILED COOLING CAPACITIES# CONDENSER ENTERINGAIR TEMPERATURES °F(°C) EVAPORATORAIR 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) Total Total Total Total Total Total CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† EWB CFM System System System System System System °F(°C) Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ KW** KW** KW** KW** KW** KW** 116BNA018****BOutdoorSectionWithCNPV*1917A** Indoor Section 72 (22.2) 21

Summary of the content on the page No. 14

14 116B DETAILED COOLING CAPACITIES# (CONT.) CONDENSER ENTERINGAIR TEMPERATURES °F(°C) EVAPORATORAIR 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) Total Total Total Total Total Total CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† EWB CFM System System System System System System °F(°C) Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ KW** KW** KW** KW** KW** KW** 116BNA030****AOutdoorSectionWithCNPV*3117A** Indoor Section

Summary of the content on the page No. 15

15 DETAILED COOLING CAPACITIES# (CONT.) CONDENSER ENTERINGAIR TEMPERATURES °F(°C) EVAPORATORAIR 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) Total Total Total Total Total Total CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† EWB CFM System System System System System System °F(°C) Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ KW** KW** KW** KW** KW** KW** 116BNA042****AOutdoorSectionWithCNPV*4324A** Indoor Section 72 (

Summary of the content on the page No. 16

16 116B DETAILED COOLING CAPACITIES# (CONT.) CONDENSER ENTERINGAIR TEMPERATURES °F(°C) EVAPORATORAIR 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) Total Total Total Total Total Total CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† EWB CFM System System System System System System °F(°C) Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ KW** KW** KW** KW** KW** KW** 116BNA049****AOutdoorSectionWithCAP**6024A* Indoor Section

Summary of the content on the page No. 17

17 DETAILED COOLING CAPACITIES# (CONT.) CONDENSER ENTERINGAIR TEMPERATURES °F(°C) EVAPORATORAIR 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) Total Total Total Total Total Total CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† CapacityMBtuh† EWB CFM System System System System System System °F(°C) Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ KW** KW** KW** KW** KW** KW** 116BNA061****AOutdoorSectionWithCNPV*6124A**+TDR Indoor Section

Summary of the content on the page No. 18

CONDENSER ONLY RATINGS SST CONDENSERENTERING AIRTEMPERATURES°F(°C) °F(°C) 55(12.78) 65(18.33) 75(23.89) 85(29.44) 95(35.0) 105(40.56) 115(46.11) 125(51.67) 116BNA018****B TCG 15.70 14.90 14.10 13.20 12.30 11.30 10.20 9.20 30 SDT 66.60 76.20 85.80 95.30 104.80 114.30 123.70 133.10 (---1.11) KW 0.75 0.87 0.99 1.12 1.26 1.41 1.60 1.81 TCG 17.50 16.60 15.70 14.70 13.70 12.60 11.50 10.30 35 SDT 67.80 77.30 86.80 96.30 105.70 115.10 124.40 133.80 (1.67) KW 0.75 0.87 0.99 1.12 1.26 1.42 1.60 1.81 TCG 1

Summary of the content on the page No. 19

CONDENSER ONLY RATINGS CONTINUED SST CONDENSERENTERING AIRTEMPERATURES°F(°C) °F(°C) 55(12.78) 65(18.33) 75(23.89) 85(29.44) 95(35.0) 105(40.56) 115(46.11) 125(51.67) 116BNA036****A TCG 31.50 29.90 28.30 26.60 24.80 22.90 21.00 18.90 30 SDT 68.90 78.20 87.50 96.80 106.20 115.50 124.90 134.20 (---1.11) KW 1.50 1.73 1.96 2.21 2.50 2.82 3.21 3.66 TCG 34.80 33.00 31.20 29.40 27.40 25.40 23.30 21.10 35 SDT 70.10 79.30 88.60 97.90 107.20 116.50 125.80 135.00 (1.67) KW 1.50 1.73 1.97 2.22 2.51 2.83 3.21

Summary of the content on the page No. 20

CONDENSER ONLY RATINGS CONTINUED SST CONDENSERENTERING AIRTEMPERATURES°F(°C) °F(°C) 55(12.78) 65(18.33) 75(23.89) 85(29.44) 95(35.0) 105(40.56) 115(46.11) 125(51.67) 116BNA049****A TCG 45.00 42.40 39.90 37.40 34.90 32.30 29.50 26.40 30 SDT 70.30 79.50 88.90 98.20 107.60 116.90 126.20 135.40 (---1.11) KW 2.04 2.41 2.75 3.08 3.44 3.84 4.32 4.89 TCG 49.80 46.80 44.00 41.20 38.50 35.60 32.60 29.30 35 SDT 71.70 80.90 90.10 99.40 108.70 118.00 127.20 136.30 (1.67) KW 1.99 2.39 2.75 3.10 3.47 3.87 4.34


Alternative user manuals
# User manual Category Download
1 Bryant 113A User manual Air Conditioner 365
2 Bryant 24B User manual Air Conditioner 61
3 Bryant 187B User manual Air Conditioner 39
4 Bryant 342S User manual Air Conditioner 17
5 Bryant 39479D8 User manual Air Conditioner 31
6 Bryant 342 User manual Air Conditioner 15
7 Bryant 165A User manual Air Conditioner 22
8 Bryant 450D User manual Air Conditioner 21
9 Bryant 451P User manual Air Conditioner 7
10 Bryant 451 User manual Air Conditioner 7
11 Bryant 36-453 User manual Air Conditioner 10
12 Bryant 452W User manual Air Conditioner 6
13 Bryant 452 User manual Air Conditioner 3
14 Bryant 454 User manual Air Conditioner 112
15 Bryant 463AAC008BA User manual Air Conditioner 17
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21