Bryant Air Conditoner 533A user manual

User manual for the device Bryant Air Conditoner 533A

Device: Bryant Air Conditoner 533A
Category: Air Conditioner
Manufacturer: Bryant
Size: 0.15 MB
Added : 11/14/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant Air Conditoner 533A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant Air Conditoner 533A.

For your convenience

If looking through the Bryant Air Conditoner 533A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant Air Conditoner 533A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant Air Conditoner 533A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant Air Conditoner 533A User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant Air Conditoner 533A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant Air Conditoner 533A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



AIR CONDITIONER 533A (60 Hz)
®
Sizes 024 thru 060
with Puron
WIDE RANGE OF SIZES—Available in 6 nominal sizes from
024 through 060 to meet the needs of residential and light
commercial applications.
COMPRESSOR—This unit features a scroll compressor,
which is significantly more efficient than conventional com-
pressors. Its simple design offers improved reliability and
each compressor is mounted on rubber isolators for addi-
tional sound reduction. Scroll compres

Summary of the content on the page No. 2

DIMENSIONS —2— SQ A AIR DISCHARGE AIR IN AIR DISCHARGE M FIELD PO WER SUPPL Y CONN 7 / - IN. DIA HOLE WITH 8 1 1 / - IN. DIA KNOCK OUT 8 3 AND 1 / - IN. DIA 8 N KNOCK OUT J K FIELD CONTROL SUPPL Y AIR IN 7 L CONN / 8 - IN. DIA AIR IN HOLE B 3 / 8 -IN. DIA TIEDO WN 3 / - IN. DIA LIQUID KNOCK OUTS 8 LINE CONN (2) PLA CES P AIR DISCHARGE 7 C 2 / 8 " E AIR IN 1 1 / 4 " D DIA V APOR LINE CONN NO TES: F 1.

Summary of the content on the page No. 3

H T G I N W I G N N O I I Y T L I P D M N O O C A C S R A I R I E S I R A Q T A A U O I N T P RECOMMENDED TUBE DIAMETERS Liquid Tube Diameter (In.) Vapor Tube Diameter (In.) UNIT 0 to 50 Ft 0 to 50 Ft Long-Line Applications* SIZE Tube Length Long-Line Applications* Tube Length (Maximum Diameter) 024 5/8 3/4 030, 036 3/4 7/8 3/8 3/8 042, 048 7/8 1-1/8 060 1-1/8 1-1/8 * For tube sets greater than 50 ft, consult Residential Split System Application Guideline and Service Man

Summary of the content on the page No. 4

SPECIFICATIONS UNIT SIZE-SERIES 024-A 030-A/A 036-A/A Operating Weight (Lb) 143 138 156 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 208/230—60—1/208/230—60—3 208/230—60—1/208/230—60—3 Operating Voltage Range* 187—253 187—253/197—253 187—253/197—253 Compressor— Rated Load Amps 13.5 14.7/9.6 15.4/12.2 Locked Rotor Amps 61.0 72.5/63.0 83.0/77.0 Condenser Fan Motor—Full Load Amps 0.50 0.80 1.4 Min Unit Ampacity for Wire Sizing 17.4 19.2/12.8 20.7/16.7 Min Wire Size (60°C Copper) A

Summary of the content on the page No. 5

SPECIFICATIONS Continued UNIT SIZE-SERIES 042-A/A 048-A/A 060-A/A Operating Weight (Lb) 197 203 238 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1/208/230—60—3 Operating Voltage Range* 187—253/197—253 Compressor—Rated Load Amps 18.6/13.5 20.5/14.7 27.6/18.1 Locked Rotor Amps 105.0/77.0 109.0/91.0 158.0/137.0 Condenser Fan Motor—Full Load Amps 1.1 1.4 1.4 Min Unit Ampacity for Wire Sizing 24.4/18.0 27.0/19.8 35.9/24.0 Min Wire Size (60°C Copper) AWG† 10/14 10/12 8/10 Min Wire Size (

Summary of the content on the page No. 6

* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure. † If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. If other than uncoated (non-plated), 60 or 75°C (140 or 167°F) ins

Summary of the content on the page No. 7

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued 9. Liquid-Line Solenoid Valve (LSV) An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. NOTE: Compressor Start Assist—Capacitor/Relay Type

Summary of the content on the page No. 8

COMBINATION RATINGS SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES MODEL BTUH MENT Rating TDR† TXV‡ EER CK5A/CK5BA030* 23,000 NONE — 12.00 12.00 10.05 CC5A/CD5AA024 23,000 NONE — 11.70 11.70 9.90 CC5A/CD5AA030 23,000 NONE — 12.00 12.00 9.95 CC5A/CD5AW024 23,000 NONE — 11.70 11.70 9.90 CC5A/CD5AW030 23,000 NONE — 12.00 12.00 9.95 CE3AA024 23,000 NONE — 11.70 11.70 10.00 CE3AA030 23,000 NONE — 12.00 12.00 10.10

Summary of the content on the page No. 9

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES MODEL BTUH MENT Rating TDR† TXV‡ EER COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE CC5A/CD5AA030 27,800 TDR 12.50 — 12.50 10.80 CC5A/CD5AA036 29,000 TDR 13.00 — 13.00 11.25 CC5A/CD5AW030 27,800 TDR 12.50 — 12.50 10.80 CK3BA030 27,800 TDR 12.50 — 12.50 10.90 CK3BA036 29,000 TDR 13.00 — 13.00 11.30 CK5A/CK5BA030 27,800 TDR 1

Summary of the content on the page No. 10

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES MODEL BTUH MENT Rating TDR† TXV‡ EER COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE CC5A/CD5AA042 34,600 TDR 13.00 — 13.00 11.15 CC5A/CD5AW036 34,600 TDR 12.50 — 12.50 11.05 CC5A/CD5AW042 34,600 TDR 13.00 — 13.00 11.05 CK3BA042 34,600 TDR 13.00 — 13.00 11.15 CK5A/CK5BA042 34,600 TDR 13.00 — 13.00 11.15 CK5A/CK5BW036 34,600

Summary of the content on the page No. 11

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES MODEL BTUH MENT Rating TDR† TXV‡ EER FV4ANF005 40,500 NONE 13.20 — 13.20 11.45 FX4ANF042 38,500 NONE 11.70 — 11.70 10.25 FX4ANF048 39,500 NONE 12.00 — 12.00 10.40 COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.20 — 12.20 10.95 CD5AA048 39,500 TDR 12.50 — 12.50 11.05 CK3BA042 39,000 TDR 12.20 — 12.

Summary of the content on the page No. 12

COMBINATION RATINGS Continued SEER FACTORY- Bryant Gas TOT. SUPPLIED Furnace or UNIT INDOOR CAP. ENHANCE- Standard Accessory Accessory SIZE-SERIES MODEL BTUH MENT Rating TDR† TXV‡ EER FG3AAA060 45,000 NONE — 11.70 11.70 10.30 FK4CNB006 46,000 TDR&TXV 13.20 — — 11.45 FK4CNF005 45,000 TDR&TXV 12.50 — — 11.15 FV4ANB006 46,000 NONE 13.20 — 13.20 11.45 FV4ANF005 45,000 NONE 12.70 — 12.70 11.15 FX4ANB060 45,500 NONE 12.00 — 12.00 10.40 FX4ANF048 45,000 NONE 11.70 — 11.70 10.20 COILS + 333(B,J)AV048

Summary of the content on the page No. 13

* Tested combination. † In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR. ‡ Based on computer simulation. TXV must be Puron® compatible and hard shutoff type. ** Ratings shown are with R-22 TXV replaced with Puron® TXV. EER — Energy Efficiency Ratio SEER — Seasonal Energy Ef

Summary of the content on the page No. 14

DETAILED COOLING CAPACITIES* CONDENSER ENTERING AIR TEMPERATURES °F EVAP AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys CFM EWB Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 533AN024-A Outdoor Section With CK5AA030 Indoor Section 72 26.7 13.0 1.84 25.7 12.6 2.06 24.6 12.2 2.29 23.3 11.8 2.56 22.0

Summary of the content on the page No. 15

DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys CFM EWB Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 533AN030-A Outdoor Section With CK5AA036 Indoor Section 72 33.8 16.9 2.24 32.6 16.5 2.49 31.2 16.0 2.76 29.5 15.5 3

Summary of the content on the page No. 16

DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys CFM EWB Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 533AN036-A Outdoor Section With CK5AA042 Indoor Section 72 40.6 20.1 2.70 39.1 19.6 3.00 37.3 19.0 3.33 35.3 18.3 3

Summary of the content on the page No. 17

DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys CFM EWB Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 533AN042-A Outdoor Section With CK5AA048 Indoor Section 72 46.5 23.0 3.09 45.1 22.7 3.44 43.0 21.9 3.81 40.7 21.2 4

Summary of the content on the page No. 18

DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys CFM EWB Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 533AN048-A Outdoor Section With CK5AA060 Indoor Section 72 53.1 26.3 3.58 51.2 25.7 3.96 49.3 25.2 4.40 47.0 24.4 4

Summary of the content on the page No. 19

DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys CFM EWB Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** 533AN060-A Outdoor Section With CK5AA060 Indoor Section 72 67.5 32.8 4.50 64.6 31.8 4.99 61.6 30.7 5.54 58.3 29.5 6

Summary of the content on the page No. 20

CONDENSER ONLY RATINGS* CONDENSER ENTERING AIR TEMPERATURES °F SST °F 55 65 75 85 95 105 115 125 533AN024-A TCG 23.3 22.1 20.8 19.6 18.3 17.0 15.7 14.4 30 SDT 76.9 86.8 96.6 107. 117. 127. 136. 146. KW 1.20 1.37 1.55 1.76 1.98 2.22 2.48 2.74 TCG 25.6 24.3 22.9 21.5 20.2 18.7 17.3 15.9 35 SDT 78.1 87.9 97.7 108. 117. 127. 137. 147. KW 1.20 1.37 1.56 1.76 1.99 2.24 2.50 2.76 TCG 28.1 26.6 25.1 23.6 22.1 20.6 19.0 17.4 40 SDT 79.5 89.2 98.9


Alternative user manuals
# User manual Category Download
1 Bryant 113A User manual Air Conditioner 365
2 Bryant 24B User manual Air Conditioner 61
3 Bryant 187B User manual Air Conditioner 39
4 Bryant 342S User manual Air Conditioner 17
5 Bryant 39479D8 User manual Air Conditioner 31
6 Bryant 342 User manual Air Conditioner 15
7 Bryant 165A User manual Air Conditioner 22
8 Bryant 450D User manual Air Conditioner 21
9 Bryant 451P User manual Air Conditioner 7
10 Bryant 451 User manual Air Conditioner 7
11 Bryant 36-453 User manual Air Conditioner 10
12 Bryant 452W User manual Air Conditioner 6
13 Bryant 452 User manual Air Conditioner 3
14 Bryant 454 User manual Air Conditioner 112
15 Bryant 463AAC008BA User manual Air Conditioner 17
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21